Researcher profile

Martin Wegener

Martin Wegener contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
7topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2021arXiv

On enhanced sensing of chiral molecules in optical cavities

The differential response of chiral molecules to incident left- and right- handed circularly polarized light is used for sensing the handedness of molecules. Currently, significant effort is directed towards enhancing weak differential signals from the molecules, with the goal of extending the capabilities of chiral spectrometers to lower molecular concentrations or small analyte volumes. Previously, optical cavities for enhancing vibrational circular dichroism have been introduced. Their enhancements are mediated by helicity-preserving cavity modes which maintain the handedness of light due to their degenerate TE and TM components. In this article, we simplify the design of the cavity, and numerically compare it with the previous one using an improved model for the response of chiral molecules. We use parameters of molecular resonances to show that the cavities are capable of bringing the vibrational circular dichroism signal over the detection threshold of typical spectrometers for concentrations that are one to three orders of magnitude smaller than those needed without the cavities, for a fixed analyte volume. Frequency resolutions of current spectrometers result in enhancements of more than one order (two orders) of magnitude for the new (previous) design. With improved frequency resolution, the new design achieves enhancements of three orders of magnitude. We show that the TE/TM degeneracy in perfectly helicity preserving modes is lifted by factors that are inherent to the cavities. More surprisingly, this degeneracy is also lifted by the molecules themselves due to their lack of electromagnetic duality symmetry, that is, due to the partial change of helicity during the light-molecule interactions.

preprint2021arXiv

Tracking Brownian motion in three dimensions and characterization of individual nanoparticles using a fiber-based high-finesse microcavity

The dynamics of nanosystems in solution contain a wealth of information with relevance for diverse fields ranging from materials science to biology and biomedical applications. When nanosystems are marked with fluorophores or strong scatterers, it is possible to track their position and reveal internal motion with high spatial and temporal resolution. However, markers can be toxic, expensive, or change the object's intrinsic properties. Here, we simultaneously measure dispersive frequency shifts of three transverse modes of a high-finesse microcavity to obtain the three-dimensional path of unlabeled SiO$_2$ nanospheres with $300$$\mathrmμ$s temporal and down to $8$nm spatial resolution. This allows us to quantitatively determine properties such as the polarizability, hydrodynamic radius, and effective refractive index. The fiber-based cavity is integrated in a direct-laser-written microfluidic device that enables the precise control of the fluid with ultra-small sample volumes. Our approach enables quantitative nanomaterial characterization and the analysis of biomolecular motion at high bandwidth.

preprint2020arXiv

Achiral, Helicity Preserving, and Resonant Structures for Enhanced Sensing of Chiral Molecules

We derive a set of design requirements that lead to structures suitable for molecular circular dichroism (CD) enhancement. Achirality of the structure and two suitably selected sequentially incident beams of opposite helicity ensures that the CD signal only depends on the chiral absorption properties of the molecules, and not on the achiral ones. Under this condition, a helicity preserving structure, which prevents the coupling of the two polarization handednesses, maximizes the enhancement of the CD signal for a given ability of the structure to enhance the field. When the achirality and helicity preservation requirements are met, the enhancement of the CD signal is directly related to the enhancement of the field. Next, we design an exemplary structure following the requirements. The considered system is a planar array of silicon cylinders under normally incident plane-wave illumination. Full-wave numerical calculations show that the enhancement of the transmission CD signal is between 6.5 and 3.75 for interaction lengths between 1.25 and 3 times the height of the cylinders.

preprint2020arXiv

Compact optical polarization-insensitive zoom metalens-doublet

Metasurface-based lenses (metalenses) offer specific conceptual advantages compared to ordinary refractive lenses. For example, it is possible to tune the focal length of a metalens doublet by varying the relative angle between the two metalenses while fixing their distance, leading to an extremely compact zoom lens. An improved polarization-insensitive design based on silicon-nanocylinders on silica substrates is presented. This design is realized and characterized experimentally at 1550 nm wavelength. By varying the relative angle between the metalenses in steps of 10 degrees, tuning of the doublet focal length is demonstrated from -54 mm to -+3 mm to +54 mm. This results in a zoom factor of an imaging system varying between 1 and 18. For positive focal lengths, the doublet focusing efficiency has a minimum of 34% and a maximum of 83%. Experiment and theory are in very good agreement.

preprint2020arXiv

Helicity-preserving optical cavity modes for enhanced sensing of chiral molecules

Researchers routinely sense molecules by their infrared vibrational "fingerprint" absorption resonances. In addition, the dominant handedness of chiral molecules can be detected by circular dichroism (CD), the normalized difference between their optical response to incident left- and right- handed circularly polarized light. Here, we introduce a cavity composed of two parallel arrays of helicity-preserving silicon disks that allows to enhance the CD signal by more than two orders of magnitude for a given molecule concentration and given thickness of the cell containing the molecules. The underlying principle is first-order diffraction into helicity-preserving modes with large transverse momentum and long lifetimes. In sharp contrast, in a conventional Fabry-Perot cavity, each reflection flips the handedness of light, leading to large intensity enhancements inside the cavity, yet to smaller CD signals than without the cavity.

preprint2020arXiv

High-Frequency Gravitational-Wave Detection Using a Chiral Resonant Mechanical Element and a Short Unstable Optical Cavity

Present gravitational wave detectors are based on the measurement of linear displacement in stable optical cavities. Here, we instead suggest the measurement of the twist of a chiral mechanical element induced by a gravitational wave. The induced twist rotates a flat optical mirror on top of this chiral element, leading to the deflection of an incident laser beam. This angle change is enhanced by multiple bounces of light between the rotating mirror and an originally parallel nearby fixed flat mirror. Based on detailed continuum-mechanics calculations, we present a feasible design for the chiral mechanical element including the rotating mirror. Our approach is most useful for signals in the frequency band 1 -- 100 kHz where we show that fundamental metrological limits would allow for smaller shot noise in this setup in comparison to the detection of linear displacement. We estimate a gravitational wave strain sensitivity between 10^{-21}/\sqrt{Hz} and 10^{-23}/\sqrt{Hz} at around 10 kHz frequency. When appropriately scaling the involved geometrical parameters, the strain sensitivity is proportional to frequency.