Researcher profile

V. Biancalana

V. Biancalana contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2013arXiv

A room-temperature alternating current susceptometer - Data analysis, calibration, and test

An AC susceptometer operating in the range of 10 Hz to 100 kHz and at room temperature is designed, built, calibrated and used to characterize the magnetic behaviour of coated magnetic nanoparticles. Other weakly magnetic materials (in amounts of some millilitres) can be analyzed as well. The setup makes use of a DAQ-based acquisition system in order to determine the amplitude and the phase of the sample magnetization as a function of the frequency of the driving magnetic field, which is powered by a digital waveform generator. A specific acquisition strategy makes the response directly proportional to the sample susceptibility, taking advantage of the differential nature of the coil assembly. A calibration method based on conductive samples is developed.

preprint2012arXiv

Larmor frequency dressing by an anharmonic transverse magnetic field

We present a theoretical and experimental study of spin precession in the presence of both a static and an orthogonal oscillating magnetic field, which is nonresonant, not harmonically related to the Larmor precession, and of arbitrary strength. Due to the intrinsic nonlinearity of the system, previous models that account only for the simple sinusoidal case cannot be applied. We suggest an alternative approach and develop a model that closely agrees with experimental data produced by an optical-pumping atomic magnetometer. We demonstrate that an appropriately designed nonharmonic field makes it possible to extract a linear response to a weak dc transverse field, despite the scalar nature of the magnetometer, which normally causes a much weaker, second-order response.

preprint2007arXiv

All optical sensor for automated magnetometry based on Coherent Population Trapping

An automated magnetometer suitable for long lasting measurement under stable and controllable experimental conditions has been implemented. The device is based on Coherent Population Trapping (CPT) produced by a multi-frequency excitation. CPT resonance is observed when a frequency comb, generated by diode laser current modulation, excites Cs atoms confined in a $π/4\times(2.5)^2\times1 \textrm{cm}^3$, 2 Torr $N_2$ buffered cell. A fully optical sensor is connected through an optical fiber to the laser head allowing for truly remote sensing and minimization of the field perturbation. A detailed analysis of the CPT resonance parameters as a function of the optical detuning has been made in order to get high sensitivity measurements. The magnetic field monitoring performances and the best sensitivity obtained in a balanced differential configuration of the sensor are presented.

preprint2007arXiv

Cs CPT magnetometer for cardio-signal detection in unshielded environment

We present first, encouraging results obtained with an experimental apparatus based on Coherent Population Trapping and aimed at detecting biological (cardiac) magnetic field in magnetically compensated, but unshielded volume. The work includes magnetic-field and magnetic-field-gradient compensation and uses differential detection for cancellation of (common mode) magnetic noise. Synchronous data acquisition with a reference (electro-cardiographic or pulse-oximetric) signal allows for improving the S/N in an off-line averaging. The set-up has the relevant advantages of working at room temperature with a small-size head, and of allowing for fast adjustments of the dc bias magnetic field, which results in making the sensor suitable for detecting the bio-magnetic signal at any orientation with respect to the heart axis and in any position around the patient chest, which is not the case with other kinds of magnetometers.