Source author record

J. Belfi

J. Belfi appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2014arXiv

A ring-lasers array for fundamental physics

After reviewing the importance of light as a probe for testing the structure of space-time, we describe the GINGER project. GINGER will be a three-dimensional array of large size ring-lasers able to measure the de Sitter and Lense-Thirring effects. The instrument will be located at the underground laboratory of GranSasso, in Italy. We describe the preliminary actions and measurements already under way and present the full road map to GINGER. The intermediate apparatuses GP2 and GINGERino are described. GINGER is expected to be fully operating in few years.

preprint2014arXiv

Interferometric length metrology for the dimensional control of ultra-stable Ring Laser Gyroscopes

We present the experimental test of a method for controlling the absolute length of the diagonals of square ring laser gyroscopes. The purpose is to actively stabilize the ring cavity geometry and to enhance the rotation sensor stability in order to reach the requirements for the detection of the relativistic Lense-Thirring effect with a ground-based array of optical gyroscopes. The test apparatus consists of two optical cavities 1.32 m in length, reproducing the features of the ring cavity diagonal resonators of large frame He-Ne ring laser gyroscopes. The proposed measurement technique is based on the use of a single diode laser, injection locked to a frequency stabilized He-Ne/Iodine frequency standard, and a single electro-optic modulator. The laser is modulated with a combination of three frequencies allowing to lock the two cavities to the same resonance frequency and, at the same time, to determine the cavity Free Spectral Range (FSR). We obtain a stable lock of the two cavities to the same optical frequency reference, providing a length stabilization at the level of 1 part in $10^{11}$, and the determination of the two FSRs with a relative precision of 0.2 ppm. This is equivalent to an error of 500 nm on the absolute length difference between the two cavities.

preprint2012arXiv

Horizontal rotation signals detected by "G-Pisa" ring laser for the Mw=9.0, March 2011, Japan earthquake

We report the observation of the ground rotation induced by the Mw=9.0, 11th of March 2011, Japan earthquake. The rotation measurements have been conducted with a ring laser gyroscope operating in a vertical plane, thus detecting rotations around the horizontal axis. Comparison of ground rotations with vertical accelerations from a co-located force-balance accelerometer shows excellent ring laser coupling at periods longer than 100s. Under the plane wave assumption, we derive a theoretical relationship between horizontal rotation and vertical acceleration for Rayleigh waves. Due to the oblique mounting of the gyroscope with respect to the wave direction-of-arrival, apparent velocities derived from the acceleration / rotation rate ratio are expected to be always larger than, or equal to the true wave propagation velocity. This hypothesis is confirmed through comparison with fundamental-mode, Rayleigh wave phase velocities predicted for a standard Earth model.

preprint2011arXiv

Measuring Gravito-magnetic Effects by Multi Ring-Laser Gyroscope

We propose an under-ground experiment to detect the general relativistic effects due to the curvature of space-time around the Earth (de Sitter effect) and to rotation of the planet (dragging of the inertial frames or Lense-Thirring effect). It is based on the comparison between the IERS value of the Earth rotation vector and corresponding measurements obtained by a tri-axial laser detector of rotation. The proposed detector consists of six large ring-lasers arranged along three orthogonal axes. In about two years of data taking, the 1% sensitivity required for the measurement of the Lense-Thirring drag can be reached with square rings of 6 $m$ side, assuming a shot noise limited sensitivity ($ 20 prad/s/\sqrt{Hz}$). The multi-gyros system, composed of rings whose planes are perpendicular to one or the other of three orthogonal axes, can be built in several ways. Here, we consider cubic and octahedron structures. The symmetries of the proposed configurations provide mathematical relations that can be used to study the stability of the scale factors, the relative orientations or the ring-laser planes, very important to get rid of systematics in long-term measurements, which are required in order to determine the relativistic effects.

preprint2010arXiv

A laser gyroscope system to detect the Gravito-Magnetic effect on Earth

Large scale square ring laser gyros with a length of four meters on each side are approaching a sensitivity of 1x10^-11 rad/s/sqrt(Hz). This is about the regime required to measure the gravitomagnetic effect (Lense Thirring) of the Earth. For an ensemble of linearly independent gyros each measurement signal depends upon the orientation of each single axis gyro with respect to the rotational axis of the Earth. Therefore at least 3 gyros are necessary to reconstruct the complete angular orientation of the apparatus. In general, the setup consists of several laser gyroscopes (we would prefer more than 3 for sufficient redundancy), rigidly referenced to each other. Adding more gyros for one plane of observation provides a cross-check against intra-system biases and furthermore has the advantage of improving the signal to noise ratio by the square root of the number of gyros. In this paper we analyze a system of two pairs of identical gyros (twins) with a slightly different orientation with respect to the Earth axis. The twin gyro configuration has several interesting properties. The relative angle can be controlled and provides a useful null measurement. A quadruple twin system could reach a 1% sensitivity after 3:2 years of data, provided each square ring has 6 m length on a side, the system is shot noise limited and there is no source for 1/f- noise.

preprint2007arXiv

All optical sensor for automated magnetometry based on Coherent Population Trapping

An automated magnetometer suitable for long lasting measurement under stable and controllable experimental conditions has been implemented. The device is based on Coherent Population Trapping (CPT) produced by a multi-frequency excitation. CPT resonance is observed when a frequency comb, generated by diode laser current modulation, excites Cs atoms confined in a $π/4\times(2.5)^2\times1 \textrm{cm}^3$, 2 Torr $N_2$ buffered cell. A fully optical sensor is connected through an optical fiber to the laser head allowing for truly remote sensing and minimization of the field perturbation. A detailed analysis of the CPT resonance parameters as a function of the optical detuning has been made in order to get high sensitivity measurements. The magnetic field monitoring performances and the best sensitivity obtained in a balanced differential configuration of the sensor are presented.

preprint2007arXiv

Cs CPT magnetometer for cardio-signal detection in unshielded environment

We present first, encouraging results obtained with an experimental apparatus based on Coherent Population Trapping and aimed at detecting biological (cardiac) magnetic field in magnetically compensated, but unshielded volume. The work includes magnetic-field and magnetic-field-gradient compensation and uses differential detection for cancellation of (common mode) magnetic noise. Synchronous data acquisition with a reference (electro-cardiographic or pulse-oximetric) signal allows for improving the S/N in an off-line averaging. The set-up has the relevant advantages of working at room temperature with a small-size head, and of allowing for fast adjustments of the dc bias magnetic field, which results in making the sensor suitable for detecting the bio-magnetic signal at any orientation with respect to the heart axis and in any position around the patient chest, which is not the case with other kinds of magnetometers.