Researcher profile

Tobias Westphal

Tobias Westphal contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2021arXiv

Measurement of Gravitational Coupling between Millimeter-Sized Masses

We demonstrate gravitational coupling between two gold spheres of approximately 1mm radius and 90mg mass. By periodically modulating the source mass position at a frequency f=12.7mHz we generate a time-dependent gravitational acceleration at the location of the test mass, which is measured off resonance in a miniature torsional balance configuration. Over an integration time of 350 hours the test mass oscillator enables measurements with a systematic accuracy of 4E-11m/s^2 and a statistical precision of 4E-12m/s^2. This is sufficient to resolve the gravitational signal at a minimal surface distance of 400mum between the two masses. We observe both linear and quadratic coupling, consistent in signal strength with a time-varying 1/r gravitational potential. Contributions of non-gravitational forces could be kept to less than 10% of the observed signal. We expect further improvements to enable the isolation of gravity as a coupling force for objects well below the Planck mass. This opens the way for precision tests of gravity in a new regime of isolated microscopic source masses.

preprint2012arXiv

A graphical description of optical parametric generation of squeezed states of light

The standard process for the production of strongly squeezed states of light is optical parametric amplification (OPA) below threshold in dielectric media such as LiNbO3 or periodically poled KTP. Here, we present a graphical description of squeezed light generation via OPA. It visualizes the interaction between the nonlinear dielectric polarization of the medium and the electromagnetic quantum field. We explicitly focus on the transfer from the field's ground state to a squeezed vacuum state and from a coherent state to a bright squeezed state by the medium's secondorder nonlinearity, respectively. Our pictures visualize the phase dependent amplification and deamplification of quantum uncertainties and give the phase relations between all propagating electro-magnetic fields as well as the internally induced dielectric polarizations. The graphical description can also be used to describe the generation of nonclassical states of light via higherorder effects of the non-linear dielectric polarization such as four-wave mixing and the optical Kerr effect.

preprint2012arXiv

Tomographic readout of an opto-mechanical interferometer

The quantum state of light changes its nature when being reflected off a mechanical oscillator due to the latter's susceptibility to radiation pressure. As a result, a coherent state can transform into a squeezed state and can get entangled with the motion of the oscillator. The complete tomographic reconstruction of the state of light requires the ability to readout arbitrary quadratures. Here we demonstrate such a readout by applying a balanced homodyne detector to an interferometric position measurement of a thermally excited high-Q silicon nitride membrane in a Michelson-Sagnac interferometer. A readout noise of $\unit{1.9 \cdot 10^{-16}}{\metre/\sqrt{\hertz}}$ around the membrane's fundamental oscillation mode at $\unit{133}{\kilo\hertz}$ has been achieved, going below the peak value of the standard quantum limit by a factor of 8.2 (9 dB). The readout noise was entirely dominated by shot noise in a rather broad frequency range around the mechanical resonance.

preprint2009arXiv

Quantum noise of a Michelson-Sagnac interferometer with translucent mechanical oscillator

Quantum fluctuations in the radiation pressure of light can excite stochastic motions of mechanical oscillators thereby realizing a linear quantum opto-mechanical coupling. When performing a precise measurement of the position of an oscillator, this coupling results in quantum radiation pressure noise. Up to now this effect has not been observed yet. Generally speaking, the strength of radiation pressure noise increases when the effective mass of the oscillator is decreased or when the power of the reflected light is increased. Recently, extremely light SiN membranes with high mechanical Q-values at room temperature have attracted attention as low thermal noise mechanical oscillators. However, the power reflectance of these membranes is much lower than unity which makes the use of advanced interferometer recycling techniques to amplify the radiation pressure noise in a standard Michelson interferometer inefficient. Here, we propose and theoretically analyze a Michelson-Sagnac interferometer that includes the membrane as a common end mirror for the Michelson interferometer part. In this new topology, both, power- and signal-recycling can be used even if the reflectance of the membrane is much lower than unity. In particular, signal-recycling is a useful tool because it does not involve a power increase at the membrane. We derive the formulas for the quantum radiation pressure noise and the shot-noise of an oscillator position measurement and compare them with theoretical models of the thermal noise of a SiN membrane with a fundamental resonant frequency of 75 kHz and an effective mass of 125 ng. We find that quantum radiation pressure noise should be observable with a power of 1 W at the central beam splitter of the interferometer and a membrane temperature of 1 K.