Source author record

Daniel Friedrich

Daniel Friedrich appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

14works
10topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

14 published item(s)

preprint2022arXiv

Beyond cost reduction: Improving the value of energy storage in electricity systems

An energy storage technology is valuable if it makes energy systems cheaper. Traditional ways to improve storage technologies are to reduce their costs; however, the cheapest energy storage is not always the most valuable in energy systems. Modern techno-economical evaluation methods try to address the cost and value situation but do not judge the competitiveness of multiple technologies simultaneously. This paper introduces the market potential method as a new complementary valuation method guiding innovation of multiple energy storage. The market potential method derives the value of technologies by examining common deployment signals from energy system model outputs in a structured way. We apply and compare this method to cost evaluation approaches in a renewables-based European power system model, covering diverse energy storage technologies. We find that characteristics of high-cost hydrogen storage can be more valuable than low-cost hydrogen storage. Additionally, we show that modifying the freedom of storage sizing and component interactions can make the energy system 10% cheaper and impact the value of technologies. The results suggest looking beyond the pure cost reduction paradigm and focus on developing technologies with suitable value approaches that can lead to cheaper electricity systems in future.

preprint2022arXiv

Reducing energy system model distortions from unintended storage cycling through variable costs

Energy model distortions may unknowingly appear and represent unrealistic and non-physical effects that can mislead optimal model decisions. A prominent misleading effect is unintended storage cycling that was observed in previous literature by simultaneous charging and discharging of the same storage in 12 of 18 energy models. Especially for popular net-zero energy model scenarios, unintended storage cycling can cause high distortions and, hence, urges for its removal. Methods to remove such misleading effects exist, but are not computational efficient and sometimes not effective such as MILP formulations. Other techniques are successful, but only if renewable energy target constraints exist. This paper explores how to eradicate unintended storage cycling for models without renewable target constraints by correctly setting variable costs of relevant system components. We find through 124 simulations that determining appropriate levels of variable costs depends on the solver accuracy used for the optimization. If set too loose, the solver prevents the removal of unintended storage cycling. We further find that reliable data for variable costs in energy modelling needs to be improved and provide a list of recommended model inputs as well as a minimum variable cost threshold that can significantly reduce the magnitude and likeliness of unintended storage cycling. Finally, our results suggest that variable cost additives may remove other known unintended energy cycling effects, such as unintended line cycling or sector cycling.

preprint2018arXiv

Possible Experimental Realization of a Basic Z2 Topological Semimetal

We report experimental and theoretical evidence that GaGeTe is a basic $Z_2$ topological semimetal with three types of charge carriers: bulk-originated electrons and holes as well as surface state electrons. This electronic situation is qualitatively similar to the primer 3D topological insulator Bi2Se3, but important differences account for an unprecedented transport scenario in GaGeTe. High-resolution angle-resolved photoemission spectroscopy combined with advanced band structure calculations show a small indirect energy gap caused by a peculiar band inversion in the \textit{T}-point of the Brillouin zone in GaGeTe. An energy overlap of the valence and conduction bands brings both electron- and hole-like carriers to the Fermi level, while the momentum gap between the corresponding dispersions remains finite. We argue that peculiarities of the electronic spectrum of GaGeTe have a fundamental importance for the physics of topological matter and may boost the material's application potential.

preprint2014arXiv

Method to reduce excess noise of a detuned cavity for application in KAGRA

Ground-based gravitational-wave detectors are based on high precision laser interferometry. One promising technique to improve the detector's sensitivity is the detuning of an optical cavity, which enhances the signal at around certain frequencies for target astronomical sources. The detuning, however, involves technical noise due to an asymmetry of the control sidebands, which includes photo-detector noise and oscillator-phase noise. Here, we introduce a solution to reduce the two kinds of excess noise using an amplitude-modulation sideband that compensates the asymmetry. The solution is planned to be implemented in the Japanese second-generation gravitational-wave detector KAGRA.

preprint2014arXiv

Precise Measurement of Laser Power using an Optomechanical System

This paper shows a novel method to precisely measure the laser power using an optomechanical system. By measuring a mirror displacement caused by the reflection of an amplitude modulated laser beam, the number of photons in the incident continuous-wave laser can be precisely measured. We have demonstrated this principle by means of a prototype experiment uses a suspended 25 mg mirror as an mechanical oscillator coupled with the radiation pressure and a Michelson interferometer as the displacement sensor. A measurement of the laser power with an uncertainty of less than one percent (1 sigma) is achievable.

preprint2013arXiv

Calculation of thermal noise in grating reflectors

Grating reflectors have been repeatedly discussed to improve the noise performance of metrological applications due to the reduction or absence of any coating material. So far, however, no quantitative estimate on the thermal noise of these reflective structures exists. In this work we present a theoretical calculation of a grating reflector's noise. We further apply it to a proposed 3rd generation gravitational wave detector. Depending on the grating geometry, the grating material and the temperature we obtain a thermal noise decrease by up to a factor of ten compared to conventional dielectric mirrors. Thus the use of grating reflectors can substantially improve the noise performance in metrological applications.

preprint2013arXiv

Invariance of waveguide grating mirrors to lateral displacement phase shifts

We present a method to analyse the coupling of lateral displacements in nanoscale structures, in particular waveguide grating mirrors (WGM), into the phase of a reflected Gaussian beam using a finite-difference time-domain simulation. Such phase noise is of interest for using WGMs in high-precision interferometry. We show that WGMs do not couple lateral displacements into the phase of a reflected beam to a precision of 10^{-7} rad and that WGMs are therefore not subject to the same stringent alignment requirements as previously proposed layouts using diffraction gratings.

preprint2012arXiv

Michelson interferometer with diffractively-coupled arm resonators in second-order Littrow configuration

Michelson-type laser-interferometric gravitational-wave (GW) observatories employ very high light powers as well as transmissively- coupled Fabry-Perot arm resonators in order to realize high measurement sensitivities. Due to the absorption in the transmissive optics, high powers lead to thermal lensing and hence to thermal distortions of the laser beam profile, which sets a limit on the maximal light power employable in GW observatories. Here, we propose and realize a Michelson-type laser interferometer with arm resonators whose coupling components are all-reflective second-order Littrow gratings. In principle such gratings allow high finesse values of the resonators but avoid bulk transmission of the laser light and thus the corresponding thermal beam distortion. The gratings used have three diffraction orders, which leads to the creation of a second signal port. We theoretically analyze the signal response of the proposed topology and show that it is equivalent to a conventional Michelson-type interferometer. In our proof-of-principle experiment we generated phase-modulation signals inside the arm resonators and detected them simultaneously at the two signal ports. The sum signal was shown to be equivalent to a single-output-port Michelson interferometer with transmissively-coupled arm cavities, taking into account optical loss. The proposed and demonstrated topology is a possible approach for future all-reflective GW observatory designs.

preprint2012arXiv

Tomographic readout of an opto-mechanical interferometer

The quantum state of light changes its nature when being reflected off a mechanical oscillator due to the latter's susceptibility to radiation pressure. As a result, a coherent state can transform into a squeezed state and can get entangled with the motion of the oscillator. The complete tomographic reconstruction of the state of light requires the ability to readout arbitrary quadratures. Here we demonstrate such a readout by applying a balanced homodyne detector to an interferometric position measurement of a thermally excited high-Q silicon nitride membrane in a Michelson-Sagnac interferometer. A readout noise of $\unit{1.9 \cdot 10^{-16}}{\metre/\sqrt{\hertz}}$ around the membrane's fundamental oscillation mode at $\unit{133}{\kilo\hertz}$ has been achieved, going below the peak value of the standard quantum limit by a factor of 8.2 (9 dB). The readout noise was entirely dominated by shot noise in a rather broad frequency range around the mechanical resonance.

preprint2011arXiv

Diffractively coupled Fabry-Perot resonator with power-recycling

We demonstrate the optical coupling of two cavities without light transmission through a substrate. Compared to a conventional coupling component, that is a partially transmissive mirror, an all-reflective coupler avoids light absorption in the substrate and therefore associated thermal problems, and even allows the use of opaque materials with possibly favourable mechanical and thermal properties. Recently, the all-reflective coupling of two cavities with a low-efficiency 3-port diffraction grating was theoretically investigated. Such a grating has an additional (a third) port. However, it was shown that the additional port does not necessarily decrease the bandwidth of the coupled cavities. Such an all-reflective scheme for cavity coupling is of interest in the field of gravitational wave detection. In such detectors light that is resonantly enhanced inside the so-called power-recycling cavity is coupled to (kilometre-scale) Fabry-Perot resonators representing the arms of a Michelson interferometer. In order to achieve a high sensitivity over a broad spectrum, the Fabry-Perot resonators need to have a high bandwidth for a given (high) power build-up. We realized such an all-reflective coupling in a table-top experiment. Our findings are in full agreement with the theoretical model incorporating the characteristics of the 3-port grating used, and therefore encourage the application of all-reflective cavity couplers in future gravitational wave detectors.

preprint2011arXiv

Waveguide grating mirror in a fully suspended 10 meter Fabry-Perot cavity

We report on the first demonstration of a fully suspended 10m Fabry-Perot cavity incorporating a waveguide grating as the coupling mirror. The cavity was kept on resonance by reading out the length fluctuations via the Pound-Drever-Hall method and employing feedback to the laser frequency. From the achieved finesse of 790 the grating reflectivity was determined to exceed 99.2% at the laser wavelength of 1064\,nm, which is in good agreement with rigorous simulations. Our waveguide grating design was based on tantala and fused silica and included a ~20nm thin etch stop layer made of Al2O3 that allowed us to define the grating depth accurately during the fabrication process. Demonstrating stable operation of a waveguide grating featuring high reflectivity in a suspended low-noise cavity, our work paves the way for the potential application of waveguide gratings as mirrors in high-precision interferometry, for instance in future gravitational wave observatories.

preprint2010arXiv

All-reflective coupling of two optical cavities with 3-port diffraction gratings

The shot-noise limited sensitivity of Michelson-type laser interferometers with Fabry-Perot arm cavities can be increased by the so-called power-recycling technique. In such a scheme the power-recycling cavity is optically coupled with the interferometer's arm cavities. A problem arises because the central coupling mirror transmits a rather high laser power and may show thermal lensing, thermo-refractive noise and photo-thermo-refractive noise. Cryogenic cooling of this mirror is also challenging, and thus thermal noise becomes a general problem. Here, we theoretically investigate an all-reflective coupling scheme of two optical cavities based on a 3-port diffraction grating. We show that power-recycling of a high-finesse arm cavity is possible without transmitting any laser power through a substrate material. The power splitting ratio of the three output ports of the grating is, surprisingly, noncritical.

preprint2010arXiv

Realization of a monolithic high-reflectivity cavity mirror from a single silicon crystal

We report on the first experimental realization of a high-reflectivity cavity mirror that solely consists of a single silicon crystal. Since no material was added to the crystal, the urgent problem of 'coating thermal noise' that currently limits classical as well as quantum measurements is avoided. Our mirror is based on a surface nanostructure that creates a resonant surface waveguide. In full agreement with a rigorous model we realized a reflectivity of (99.79+/-0.01)% at a wavelength of 1.55 μm, and achieved a cavity finesse of 2784. We anticipate that our achievement will open the avenue to next generation high-precision experiments targeting fundamental questions of physics.

preprint2009arXiv

Quantum noise of a Michelson-Sagnac interferometer with translucent mechanical oscillator

Quantum fluctuations in the radiation pressure of light can excite stochastic motions of mechanical oscillators thereby realizing a linear quantum opto-mechanical coupling. When performing a precise measurement of the position of an oscillator, this coupling results in quantum radiation pressure noise. Up to now this effect has not been observed yet. Generally speaking, the strength of radiation pressure noise increases when the effective mass of the oscillator is decreased or when the power of the reflected light is increased. Recently, extremely light SiN membranes with high mechanical Q-values at room temperature have attracted attention as low thermal noise mechanical oscillators. However, the power reflectance of these membranes is much lower than unity which makes the use of advanced interferometer recycling techniques to amplify the radiation pressure noise in a standard Michelson interferometer inefficient. Here, we propose and theoretically analyze a Michelson-Sagnac interferometer that includes the membrane as a common end mirror for the Michelson interferometer part. In this new topology, both, power- and signal-recycling can be used even if the reflectance of the membrane is much lower than unity. In particular, signal-recycling is a useful tool because it does not involve a power increase at the membrane. We derive the formulas for the quantum radiation pressure noise and the shot-noise of an oscillator position measurement and compare them with theoretical models of the thermal noise of a SiN membrane with a fundamental resonant frequency of 75 kHz and an effective mass of 125 ng. We find that quantum radiation pressure noise should be observable with a power of 1 W at the central beam splitter of the interferometer and a membrane temperature of 1 K.