Source author record

Tiarnan Mullarkey

Tiarnan Mullarkey appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
3close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Using Your Beam Efficiently: Reducing Electron-dose in the STEM via Flyback Compensation

In the scanning transmission electron microscope, fast-scanning and frame-averaging are two widely used approaches for reducing electron-beam damage and increasing image signal-noise ratio which require no additional specialised hardware. Unfortunately, for scans with short pixel dwell-times (less than 5 $μ$s), line flyback time represents an increasingly wasteful overhead. Although beam exposure during flyback causes damage while yielding no useful information, scan-coil hysteresis means that eliminating it entirely leads to unacceptably distorted images. In this work, we reduce this flyback to an absolute minimum by calibrating and correcting for this hysteresis in postprocessing. Substantial improvements in dose-efficiency can be realised (up to 20 %), while crystallographic and spatial fidelity is maintained for displacement/strain measurement.

preprint2020arXiv

Development of a Practicable Digital Pulse Read-out for Dark-field STEM

When characterising beam-sensitive materials in the scanning transmission electron microscope (STEM), low-dose techniques are essential for the reliable observation of samples in their true state. A simple route to minimise both the total electron-dose and the dose-rate is to reduce the electron beam-current and/or raster the probe at higher speeds. At the limit of these settings, and with current detectors, the resulting images suffer from unacceptable artefacts including; signal-streaking, detector-afterglow, and poor signal-to-noise ratios (SNR). In this manuscript we present an alternative approach to capture dark-field STEM images by pulse-counting individual electrons as they are scattered to the annular dark-field (ADF) detector. Digital images formed in this way are immune from analogue artefacts of streaking or afterglow and allow clean, high-SNR images to be obtained even at low beam-currents. We present results from both a ThermoFisher FEI Titan G2 operated at 300kV and a Nion UltraSTEM200 operated at 200kV, and compare the images to conventional analogue recordings. ADF data are compared with analogue counterparts for each instrument, a digital detector-response scan is performed on the Titan, and the overall rastering efficiency is evaluated for various scanning parameters.