Source author record

Svenja Lohmann

Svenja Lohmann appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

Assessing electron emission induced by pulsed ion beams: a time-of-flight approach

We present a method to measure the kinetic energy of electrons emitted upon ion impact via their time-of-flight. Pulsed beams of H$^{+}$, D$_2^{+}$, He$^{+}$ and Ne$^{+}$ ions with velocities between 0.4 and 3.5 a.u. are transmitted through thin, self-supporting carbon and gold foils. Transmitted ions and secondary electrons are detected with a position-sensitive detector behind the sample and their respective energies are determined via their flight times. A coincidence criterium can be applied in the acquisition software. Measured electron energies range between 10 and 400 eV. Above ion velocities of 1 a.u. the most probable electron energy scales with ion velocity pointing towards a kinetic emission mechanism. At lower ion velocities, the electron energy stays constant and lies above the maximum energy transfer possible in a classical binary collision between ion and electron. Potential applications and technical challenges of measuring electron energies and yields with a time-of-flight approach are discussed.

preprint2020arXiv

Disparate energy scaling of trajectory-dependent electronic excitations for slow protons and He ions

We have simultaneously measured angular distributions and electronic energy loss of helium ions and protons directly transmitted through self-supporting, single-crystalline silicon foils. We have compared the energy loss along channelled and random trajectories for incident ion energies between 50 keV and 200 keV. For all studied cases the energy loss in channelling geometry is found lower than in random geometry. In the case of protons, this difference increases with initial ion energy. This behaviour can be explained by the increasing contribution of excitations of core electrons, which are more likely to happen at small impact parameters accessible only in random geometry. For helium ions we observe a reverse trend - a decrease of the difference between channelled and random energy loss for increasing ion energy. Due to the inefficiency of core-electron excitations even at small impact parameters at such low energies, another mechanism has to be the cause for the observed difference. We provide evidence that the observation originates from reionisation events induced by close collisions of helium ions occurring only along random trajectories.

preprint2016arXiv

The Cryogenic Storage Ring CSR

An electrostatic cryogenic storage ring, CSR, for beams of anions and cations with up to 300 keV kinetic energy per unit charge has been designed, constructed and put into operation. With a circumference of 35 m, the ion-beam vacuum chambers and all beam optics are in a cryostat and cooled by a closed-cycle liquid helium system. At temperatures as low as (5.5 $\pm$ 1) K inside the ring, storage time constants of several minutes up to almost an hour were observed for atomic and molecular, anion and cation beams at an energy of 60 keV. The ion-beam intensity, energy-dependent closed-orbit shifts (dispersion) and the focusing properties of the machine were studied by a system of capacitive pickups. The Schottky-noise spectrum of the stored ions revealed a broadening of the momentum distribution on a time scale of 1000 s. Photodetachment of stored anions was used in the beam lifetime measurements. The detachment rate by anion collisions with residual-gas molecules was found to be extremely low. A residual-gas density below 140 cm$^{-3}$ is derived, equivalent to a room-temperature pressure below 10$^{-14}$ mbar. Fast atomic, molecular and cluster ion beams stored for long periods of time in a cryogenic environment will allow experiments on collision- and radiation-induced fragmentation processes of ions in known internal quantum states with merged and crossed photon and particle beams.