Researcher profile

Andreas Wolf

Andreas Wolf contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - Emerging
8works
0followers
9topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2022arXiv

Fast- and thermal-neutron detection with common NaI(Tl) detectors

Radionuclide Identification Devices (RIDs) or Backpack Radiation Detection Systems (BRDs) are often equipped with NaI(Tl) detectors. We demonstrate that such instruments could be provided with reasonable thermal- and fast-neutron sensitivity by means of an improved and sophisticated processing of the digitized detector signals: Fast neutrons produce nuclear recoils in the scintillation crystal. Corresponding signals are detectible and can be distinguished from that of electronic interactions by pulse-shape discrimination (PSD) techniques as used in experiments searching for weakly interacting massive particles (WIMPs). Thermal neutrons are often captured in iodine nuclei of the scintillator. The gamma-ray cascades following such captures comprise a sum energy of almost 7 MeV, and some of them involve isomeric states leading to delayed gamma emissions. Both features can be used to distinguish corresponding detector signals from responses to ambient gamma radiation. The experimental proof was adduced by offline analyses of pulse records taken with a commercial RID. An implementation of such techniques in commercial RIDs is feasible.

preprint2022arXiv

Laser-probing the rotational cooling of molecular ions by electron collisions

We present state-selected measurements of rotational cooling and excitation rates of CH$^+$ molecular ions by inelastic electron collisions. The experiments are carried out at the Cryogenic Storage Ring, making use of a monoenergetic electron beam at matched velocity in combination with state-sensitive laser-dissociation of the CH$^+$ ions for simultaneous monitoring of the rotational level populations. Employing storage times of up to 600 s, we create conditions where electron-induced cooling to the $J = 0$ ground state dominates over radiative relaxation, allowing for the experimental determination of inelastic electron collision rates to benchmark state-of-the-art theoretical calculations. On a broader scale, our experiments pave the way to probe inelastic electron collisions for a variety of molecular ions relevant in various plasma environments.

preprint2016arXiv

The Cryogenic Storage Ring CSR

An electrostatic cryogenic storage ring, CSR, for beams of anions and cations with up to 300 keV kinetic energy per unit charge has been designed, constructed and put into operation. With a circumference of 35 m, the ion-beam vacuum chambers and all beam optics are in a cryostat and cooled by a closed-cycle liquid helium system. At temperatures as low as (5.5 $\pm$ 1) K inside the ring, storage time constants of several minutes up to almost an hour were observed for atomic and molecular, anion and cation beams at an energy of 60 keV. The ion-beam intensity, energy-dependent closed-orbit shifts (dispersion) and the focusing properties of the machine were studied by a system of capacitive pickups. The Schottky-noise spectrum of the stored ions revealed a broadening of the momentum distribution on a time scale of 1000 s. Photodetachment of stored anions was used in the beam lifetime measurements. The detachment rate by anion collisions with residual-gas molecules was found to be extremely low. A residual-gas density below 140 cm$^{-3}$ is derived, equivalent to a room-temperature pressure below 10$^{-14}$ mbar. Fast atomic, molecular and cluster ion beams stored for long periods of time in a cryogenic environment will allow experiments on collision- and radiation-induced fragmentation processes of ions in known internal quantum states with merged and crossed photon and particle beams.

preprint2015arXiv

An Efficient, Movable Single-Particle Detector for Use in Cryogenic Ultra-High Vacuum Environments

A compact, highly efficient single-particle counting detector for ions of keV/u kinetic energy, movable by a long-stroke mechanical translation stage, has been developed at the Max-Planck-Institut für Kernphysik (Max Planck Institute for Nuclear Physics, MPIK). Both, detector and translation mechanics, can operate at ambient temperatures down to $\sim$ 10 K and consist fully of ultra-high vacuum (UHV) compatible, high-temperature bakeable and non-magnetic materials. The set-up is designed to meet the technical demands of MPIK's Cryogenic Storage Ring (CSR). We present a series of functional tests that demonstrate full suitability for this application and characterise the set-up with regard to its particle detection efficiency.

preprint2015arXiv

Visible line intensities of the triatomic hydrogen ion from experiment and theory

The visible spectrum of H3+ is studied using high-sensitivity action spectroscopy in a cryogenic radiofrequency multipole trap. Advances are made to measure the weak ro-vibrational transitions from the lowest rotational states of H3+ up to high excitation energies providing visible line intensities and, after normalisation to an infrared calibration line, the corresponding Einstein $B$ coefficients. {\it Ab initio} predictions for the Einstein $B$ coefficients are obtained from a highly precise dipole moment surface of H3+ and found to be in excellent agreement, even in the region where states have been classified as chaotic.

preprint2014arXiv

Test of Time Dilation Using Stored Li+ Ions as Clocks at Relativistic Speed

We present the concluding result from an Ives-Stilwell-type time dilation experiment using 7Li+ ions confined at a velocity of beta = v/c = 0.338 in the storage ring ESR at Darmstadt. A Lambda-type three-level system within the hyperfine structure of the 7Li+ triplet S1-P2 line is driven by two laser beams aligned parallel and antiparallel relative to the ion beam. The lasers&#39; Doppler shifted frequencies required for resonance are measured with an accuracy of < 4 ppb using optical-optical double resonance spectroscopy. This allows us to verify the Special Relativity relation between the time dilation factor gamma and the velocity beta to within 2.3 ppb at this velocity. The result, which is singled out by a high boost velocity beta, is also interpreted within Lorentz Invariance violating test theories.

preprint2010arXiv

Resonant structure of low-energy H3+ dissociative recombination

New high-resolution dissociative recombination rate coefficients of rotationally cool and hot H3+ in the vibrational ground state have been measured with a 22-pole trap setup and a Penning ion source, respectively, at the ion storage ring TSR. The experimental results are compared with theoretical calculations to explore the dependence of the rate coefficient on ion temperature and to study the contributions of different symmetries to probe the rich predicted resonance spectrum. The break-up energy was investigated by fragment imaging to derive internal temperatures of the stored parent ions under differing experimental conditions. A systematic experimental assessment of heating effects is performed which, together with a survey of other recent storage-ring data, suggests that the present rotationally cool rate-coefficient measurement was performed at 380^{+50}_{-130} K and that this is the lowest rotational temperature so far realized in storage-ring rate-coefficient measurements on H3+. This partially supports the theoretical suggestion that higher temperatures than assumed in earlier experiments are the main cause for the large gap between the experimental and theoretical rate coefficients. For the rotationally hot rate-coefficient measurement a temperature of below 3250K is derived. From these higher-temperature results it is found that increasing the rotational ion temperature in the calculations cannot fully close the gap between the theoretical and experimental rate coefficients.

preprint2008arXiv

Chemical probing spectroscopy of H3+ above the barrier to linearity

We have performed chemical probing spectroscopy of H3+ ions trapped in a cryogenic 22-pole ion trap. The ions were buffer-gas cooled to 55K by collisions with helium and argon. Excitation to states above the barrier to linearity was achieved by a Ti:Sa laser operated between 11300 and 13300 cm-1. Subsequent collisions of the excited H3+ ions with argon lead to the formation of ArH+ ions that were detected by a quadrupole mass spectrometer with high sensitivity. We report the observation of 17 previously unobserved transitions to states above the barrier to linearity. Comparison to theoretical calculations suggests that the transition strengths of some of these lines are more than five orders of magnitude smaller than those of the fundamental band, which renders them - to the best of our knowledge - the weakest H3+ transitions observed to date.