Researcher profile

Susanne Mertens

Susanne Mertens contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
8works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2022arXiv

Background reduction at the KATRIN experiment by the shifted analysing plane configuration

The KATRIN experiment aims at measuring the electron neutrino mass with a sensitivity of 0.2 eV$/c^2$ after five years of data taking. Recently a new upper limit for the neutrino mass of 0.8 eV$/c^2$ (90% CL) was obtained. To reach the design sensitivity, a reduction of the background rate by one order of magnitude is required. The shifted analysing plane (SAP) configuration exploits a specific shaping of the electric and magnetic fields in the KATRIN main spectrometer to reduce the spectrometer background by a factor of two. We discuss the general idea of the SAP configuration and describe the main features of this novel measurement mode.

preprint2022arXiv

Fast and precise model calculation for KATRIN using a neural network

We present a fast and precise method to approximate the physics model of the Karlsruhe Tritium Neutrino (KATRIN) experiment using a neural network. KATRIN is designed to measure the effective electron anti-neutrino mass using the kinematics of beta-decay with a sensitivity of 200 meV at 90% confidence level. To achieve this goal, a highly accurate model prediction with relative errors below the 1e-4-level is required. Using the regular numerical model for the analysis of the final KATRIN dataset is computationally extremely costly or requires approximations to decrease the computation time. Our solution to reduce the computational requirements is to train a neural network to learn the predicted beta-spectrum and its dependence on all relevant input parameters. This results in a speed-up of the calculation by about three orders of magnitude, while meeting the stringent accuracy requirements of KATRIN.

preprint2020arXiv

Characterization of a Silicon Drift Detector for High-Resolution Electron Spectroscopy

Silicon Drift Detectors, widely employed in high-resolution and high-rate X-ray applications, are considered here with interest also for electron detection. The accurate measurement of the tritium beta decay is the core of the TRISTAN (TRitium Investigation on STerile to Active Neutrino mixing) project. This work presents the characterization of a single-pixel SDD detector with a mono-energetic electron beam obtained from a Scanning Electron Microscope. The suitability of the SDD to detect electrons, in the energy range spanning from few keV to tens of keV, is demonstrated. Experimental measurements reveal a strong effect of the detector's entrance window structure on the observed energy response. A detailed detector model is therefore necessary to reconstruct the spectrum of an unknown beta-decay source.

preprint2020arXiv

Characterization of the Detector Response to Electrons of Silicon Drift Detectors for the TRISTAN Project

Right-handed neutrinos are a natural extension of the Standard Model of particle physics. Such particles would only interact through the mixing with the left-handed neutrinos, hence they are called sterile neutrinos. If their mass were in the keV-range they would be Dark Matter candidates. By investigating the electron spectrum of the tritium beta-decay the parameter space with masses up to the endpoint of 18.6 keV can be probed. A sterile neutrino manifests as a kink-like structure in the spectrum. To achieve this goal the TRISTAN project develops a new detector system for the KATRIN experiment that can search for these new particles using the silicon drift detector technology. One major effect on the performance of the detectors is the so called dead layer. Here, a new characterization method for the prototype detectors is presented using the Kr-83m decay conversion electrons. By tilting the detector its effective dead layer increases, which leads to different peak positions. The difference of peak positions between two tilting angles is independent of source effects and is thus suitable for characterization.A dead layer is then extracted by comparing the measurements to Monte-Carlo simulations. A dead layer in the order of 50 nm was found.

preprint2020arXiv

Electron spectrometry with SDDs: a GEANT4 based method for detector response reconstruction

Electron spectrometry is traditionally challenging due to the difficulty of correctly reconstructing the original energy of the detected electrons. Silicon Drift Detectors, extensively used for X-ray spectrometry, are a promising technology for the precise measurement of electrons energy. The ability to correctly model the detector entrance window response to the energy deposited by electrons is a critical aspect of this application. We hereby describe a MonteCarlo-based approach to this problem, together with characterization and validation measurements performed with electron beams from a Scanning Electron Microscope.

preprint2020arXiv

Hunting keV sterile neutrinos with KATRIN: building the first TRISTAN module

The KATRIN (Karlsruhe Tritium Neutrino) experiment investigates the energetic endpoint of the tritium beta-decay spectrum to determine the effective mass of the electron anti-neutrino. The collaboration has reported a first mass measurement result at this TAUP-2019 conference. The TRISTAN project aims at detecting a keV-sterile neutrino signature by measuring the entire tritium beta-decay spectrum with an upgraded KATRIN system. One of the greatest challenges is to handle the high signal rates generated by the strong activity of the KATRIN tritium source while maintaining a good energy resolution. Therefore, a novel multi-pixel silicon drift detector and read-out system are being designed to handle rates of about 100 Mcps with an energy resolution better than 300 eV (FWHM). This report presents succinctly the KATRIN experiment, the TRISTAN project, then the results of the first 7-pixels prototype measurement campaign and finally describes the construction of the first TRISTAN module composed of 166 SDD-pixels as well as its implementation in KATRIN experiment.

preprint2019arXiv

Development of signal readout electronics for LEGEND-1000

The Large Enriched Germanium Experiment for Neutrinoless $ββ$ Decay (LEGEND) is a future ton-scale experimental program that will search for neutrinoless double beta decay ($0νββ$) in the isotope $^{76}$Ge with an unprecedented sensitivity. To achieve the projected discovery sensitivity at a half-life beyond $10^{28}\,$yr after about ten years of data taking, it is of utmost importance to operate in a background-free environment. This can be supported by using highly integrated readout electronics such as application-specific integrated circuit (ASIC) technology. In this work we investigated the properties and electronic performance of a commercially available ASIC charge sensitive preamplifier, the XGLab CUBE preamplifier, together with a p-type point contact high-purity germanium detector.

preprint2019arXiv

Measurements with a TRISTAN prototype detector system at the "Troitsk nu-mass" experiment in integral and differential mode

Sterile neutrinos emerge in minimal extensions of the Standard Model which can solve a number of open questions in astroparticle physics. For example, sterile neutrinos in the keV-mass range are viable dark matter candidates. Their existence would lead to a kink-like distortion in the tritium $β$-decay spectrum. In this work we report about the instrumentation of the Troitsk nu-mass experiment with a 7-pixel TRISTAN prototype detector and measurements in both differential and integral mode. The combination of the two modes is a key requirement for a precise sterile neutrino search, as both methods are prone to largely different systematic uncertainties. Thanks to the excellent performance of the TRISTAN detector at high rates, a sterile neutrino search up to masses of about 6 keV could be performed, which enlarges the previous accessible mass range by a factor of 3. Upper limits on the neutrino mixing amplitude in the mass range < 5.6 keV (differential) and < 6.6 keV (integral) are presented. These results demonstrate the feasibility of a sterile neutrino search as planned in the upgrade of the KATRIN experiment with the final TRISTAN detector and read-out system.