Source author record

Stéphane Guérandel

Stéphane Guérandel appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2021arXiv

High-performance coherent population trapping atomic clock with direct-modulation distributed Bragg reflector laser

The coherent population trapping (CPT) atomic clock is very promising for use in next-generation spaceborne applications owing to its compactness and high performance. In this paper, we propose and implement a CPT atomic clock based on the direct modulation of a large-modulation-bandwidth and narrow-linewidth distributed Bragg reflector laser, which replaces the usually used external bulk modulator in the high-performance CPT clock. Our method retains the high performance while significantly reducing the size. Using this highly compact bichromatic light source and simplest CPT configuration, in which a circularly polarized bichromatic laser interrogates the ^{87}Rb atom system, a CPT signal of clock transition with a narrow linewidth and high contrast is observed. We then lock the local oscillator frequency to the CPT error signal and demonstrate a short-term frequency stability of 3.6 \times 10^{-13} τ^{-1/2} (4 s \le τ \le 200 s). We attribute it to the ultralow laser frequency and intensity noise as well as to the high-quality-factor CPT signal. This study can pave the way for the development of compact high-performance CPT clocks based on our scheme.

preprint2015arXiv

Characterization of Cs vapor cell coated with octadecyltrichlorosilane using coherent population trapping spectroscopy

We report the realization and characterization using coherent population trapping (CPT) spectroscopy of an octadecyltrichlorosilane (OTS)-coated centimeter-scale Cs vapor cell. The dual-structure of the resonance lineshape, with presence of a narrow structure line at the top of a Doppler-broadened structure, is clearly observed. The linewidth of the narrow resonance is compared to the linewidth of an evacuated Cs cell and of a buffer gas Cs cell of similar size. The Cs-OTS adsorption energy is measured to be (0.42 $\pm$ 0.03) eV, leading to a clock frequency shift rate of $2.7\times10^{-9}/$K in fractional unit. A hyperfine population lifetime, $T_1$, and a microwave coherence lifetime, $T_2$, of 1.6 and 0.5 ms are reported, corresponding to about 37 and 12 useful bounces, respectively. Atomic-motion induced Ramsey narrowing of dark resonances is observed in Cs-OTS cells by reducing the optical beam diameter. Ramsey CPT fringes are detected using a pulsed CPT interrogation scheme. Potential applications of the Cs-OTS cell to the development of a vapor cell atomic clock are discussed.

preprint2014arXiv

Dick effect in a pulsed atomic clock using Coherent Population Trapping

The Dick effect can be a limitation of the achievable frequency stability of a passive atomic frequency standard when the ancillary frequency source is only periodically sampled. Here we analyze the Dick effect for a pulsed vapor cell clock using coherent population trapping (CPT). Due to its specific interrogation process without atomic preparation nor detection outside of the Ramsey pulses, it exhibits an original shape of the sensitivity function to phase noise of the oscillator. Numerical calculations using a three-level atom model are successfully compared with measurements; an approximate formula of the sensitivity function is given as an easy-to-use tool. A comparison of our CPT clock sensitivity to phase noise with a clock of the same duty cycle using a two-level system reveals a higher sensitivity in the CPT case. The influence of a free-evolution time variation and of a detection duration lengthening on this sensitivity is studied. Finally this study permitted to choose an adapted quartz oscillator and allowed an improvement of the clock fractional frequency stability at the level of 3.2x10-13 at 1s

preprint2014arXiv

Limitations of long term stability in a coherent population trapping Cs clock

Vapor cell atomic clocks exhibit reduced frequency stability for averaging time between about one hundred and a few thousand seconds. Here we report a study on the impact of the main parameters on the mid-to-long term instability of a buffer-gas vapor cell Cs clock, based on coherent population trapping (CPT). The CPT signal is observed on the Cs D1 line transmission, using a double $Λ$ scheme and a Ramsey interrogation technique. The effects on the clock frequency of the magnetic field, the cell temperature, and the laser intensities are reported. We show in particular that the laser intensity shift is temperature dependent. Along with the laser intensity ratio and laser polarization properties, this is one of the most important parameters.

preprint2013arXiv

Coherent Population Trapping Resonances in Buffer Gas-filled Cs Vapor Cells with Push-Pull Optical Pumping

We report on a theoretical study and experimental characterization of coherent population trapping (CPT) resonances in buffer gas-filled vapor cells with push-pull optical pumping (PPOP) on Cs D1 line. We point out that the push-pull interaction scheme is identical to the so-called lin per lin polarization scheme. Expressions of the relevant dark states, as well as of absorption, are reported. The experimental setup is based on the combination of a distributed feedback (DFB) diode laser, a pigtailed intensity Mach-Zehnder electro-optic modulator (MZ EOM) for optical sidebands generation and a Michelson-like interferometer. A microwave technique to stabilize the transfer function operating point of the MZ EOM is implemented for proper operation. A CPT resonance contrast as high as 78% is reported in a cm-scale cell for the magnetic-field insensitive clock transition. The impact of the laser intensity on the CPT clock signal key parameters (linewidth - contrast - linewidth/contrast ratio) is reported for three different cells with various dimensions and buffer gas contents. The potential of the PPOP technique for the development of high-performance atomic vapor cell clocks is discussed.

preprint2013arXiv

Ramsey spectroscopy of high-contrast CPT resonances with push-pull optical pumping in Cs vapor

We report the detection of high-contrast and narrow Coherent Population Trapping (CPT) Ramsey fringes in a Cs vapor cell using a simple-architecture laser system. The latter allows the combination of push-pull optical pumping (PPOP) and a temporal Ramsey-like pulsed interrogation. An originality of the optics package is the use of a single Mach-Zehnder electro-optic modulator (MZ EOM) both for optical sidebands generation and light switch for pulsed interaction. Typical Ramsey fringes with a linewidth of 166 Hz and a contrast of 33 % are detected in a cm-scale buffer-gas filled Cs vapor cell. This technique could be interesting for the development of high-performance and low power consumption compact vapor cell clocks based on CPT.

preprint2011arXiv

Temperature Dependence Cancellation of the Cs Clock Frequency in the Presence of Ne Buffer Gas

The temperature dependence of the Cs clock transition frequency in a vapor cell filled with Ne buffer gas has been measured. The experimental setup is based on the coherent population trapping (CPT) technique and a temporal Ramsey interrogation allowing a high resolution. A quadratic dependence of the frequency shift is shown. The temperature of the shift cancellation is evaluated. The actual Ne pressure in the cell is determined from the frequency shift of the 895nm optical transition. We can then determine the Cs-Ne collisional temperature coefficients of the clock frequency. These results can be useful for vapor cell clocks and especially for future micro-clocks.