Researcher profile

Siegfried Janz

Siegfried Janz contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

Astrophotonic Solutions for Spectral Cross-Correlation Techniques

Using photonic devices, we developed a new approach to traditional spectroscopy where the spectral cross-correlation with a template spectrum can be done entirely on-device. By creating photonic devices with a carefully designed, modulated transmission spectrum, the cross-correlation can be carried out optically without requiring any dispersion, vastly simplifying the instrument and reducing its cost. The measured correlation lag can be used for detecting atomic/molecular species within and determining the radial velocity of a particular astrophysical object. We present an overview of two design approaches that are currently being developed that use different photonic platforms: silicon and fibre-based photonics. The silicon photonic approach utilizes ring resonators that can be thermo-optically modulated to carry out the cross-correlation. The fibre approach uses customized fibre Bragg gratings (FBGs) with transmission spectra that can be strain-modulated. Both approaches have been able to detect molecular gas in a lab setting, and we are now in the process of on-sky testing. Lastly, we discuss the future for these types of devices as their simplicity opens up the possibility of developing low-cost, purpose-built multi-object or integral field spectroscopic instruments that could make significant contributions to scientific programs requiring stellar RV measurements and exoplanet detections.

preprint2022arXiv

Athermal and tunable echelle grating wavelength demultiplexers using a Mach-Zehnder interferometer launch structure

We present a comparative experimental study of three silicon photonic echelle grating demultiplexers that are integrated with a Mach-Zehnder interferometer (MZI) launch structure. By appropriate choice of the MZI configuration, the temperature induced shift of the demultiplexer channel wavelengths can be suppressed (athermal) or enhanced (super-thermal), or be controlled by an on-chip micro-heater. The latter two configurations allow the channel wavelengths to be actively tuned using lower power than possible by temperature tuning a conventional echelle demultiplexer. In the athermal configuration, the measured channel spectral shift is reduced to less than 10 pm/C, compared to the 83 pm/C shift for an unmodified echelle device. In super-thermal operation an enhanced channel temperature tuning rate of 170 pm/C is achieved. Finally, by modulating the MZI phase with an on-chip heater, the demultiplexer channels can be actively tuned to correct for ambient temperature fluctuations up to 20 C, using a drive current of less than 20 mA.

preprint2022arXiv

PCA-Boosted Autoencoders for Nonlinear Dimensionality Reduction in Low Data Regimes

Autoencoders (AE) provide a useful method for nonlinear dimensionality reduction but are ill-suited for low data regimes. Conversely, Principal Component Analysis (PCA) is data-efficient but is limited to linear dimensionality reduction, posing a problem when data exhibits inherent nonlinearity. This presents a challenge in various scientific and engineering domains such as the nanophotonic component design, where data exhibits nonlinear features while being expensive to obtain due to costly real measurements or resource-consuming solutions of partial differential equations. To address this difficulty, we propose a technique that harnesses the best of both worlds: an autoencoder that leverages PCA to perform well on scarce nonlinear data. Specifically, we outline a numerically robust PCA-based initialization of AE, which, together with the parameterized ReLU activation function, allows the training process to start from an exact PCA solution and improve upon it. A synthetic example is presented first to study the effects of data nonlinearity and size on the performance of the proposed method. We then evaluate our method on several nanophotonic component design problems where obtaining useful data is expensive. To demonstrate universality, we also apply it to tasks in other scientific domains: a benchmark breast cancer dataset and a gene expression dataset. We show that our proposed approach is substantially better than both PCA and randomly initialized AE in the majority of low-data regime cases we consider, or at least is comparable to the best of either of the other two methods.

preprint2020arXiv

Design of Compact and Efficient Silicon Photonic Micro Antennas with Perfectly Vertical Emission

Compact and efficient optical antennas are fundamental components for many applications, including high-density fiber-chip coupling and optical phased arrays. Here we present the design of grating-based micro-antennas with perfectly vertical emission in the 300-nm silicon-on-insulator platform. We leverage a methodology combining adjoint optimization and machine learning dimensionality reduction to efficiently map the multiparameter design space of the antennas, analyse a large number of relevant performance metrics, carry out the required multi-objective optimization, and discover high performance designs. Using a one-step apodized grating we achieve a vertical upward diffraction efficiency of almost 92% with a 3.6 μm-long antenna. When coupled with an ultra-high numerical aperture fiber, the antenna exhibits a coupling efficiency of more than 81% (-0.9 dB) and a 1-dB bandwidth of almost 158 nm. The reflection generated by the perfectly vertical antenna is smaller than -20 dB on a 200-nm bandwidth centered at λ = 1550 nm.

preprint2020arXiv

Photonic Temperature and Wavelength Metrology by Spectral Pattern Recognition

Spectral pattern recognition is used to measure temperature and generate calibrated wavelength/frequency combs using a single silicon waveguide ring resonator. The ring generates two incommensurate interleaving TE and TM spectral combs that shift independently with temperature to create a spectral pattern that is unique at every temperature. Following an initial calibration, the ring temperature can be determined by recognizing the spectral resonance pattern, and as a consequence the wavelength of every resonance is also known. Two methods of pattern based temperature retrieval are presented. In the first method, the ring is locked to a previously determined temperature set-point defined by the coincidence of only two specific TE and TM cavity modes. Based on a prior calibration at the set-point, the ring temperature and hence all resonance wavelengths are then known and the resulting comb can be used as a wavelength calibration reference. In this configuration, all reference comb wavelengths have been reproduced within a 5 pm accuracy across an 80 nm range by using an on-chip micro-heater to tune the ring. For more general photonic thermometry, a spectral correlation algorithm is developed to recognize a resonance pattern across a 30 nm wide spectral window and thereby determine ring temperature continuously to 50 mK accuracy. The correlation method is extended to simultaneously determine temperature and to identify and correct for wavelength calibration errors in the interrogating light source. The temperature and comb wavelength accuracy is limited primarily by the linewidth of the ring resonances, with accuracy and resolution scaling with the ring quality factor.

preprint2020arXiv

Spectrum-free integrated photonic remote molecular identification and sensing

Absorption spectroscopy is widely used in sensing and astronomy to understand molecular compositions on microscopic to cosmological scales. However, typical dispersive spectroscopic techniques require multichannel detection, fundamentally limiting the ability to detect extremely weak signals when compared to direct photometric methods. We report the realization of direct spectral molecular detection using a silicon nanophotonic waveguide resonator, obviating dispersive spectral acquisition. We use a thermally tunable silicon ring resonator with a transmission spectrum matched and cross-correlated to the quasi-periodic vibronic absorption lines of hydrogen cyanide. We show that the correlation peak amplitude is proportional to the number of overlapping ring resonances and gas lines, and that molecular specificity is obtained from the phase of the correlation signal in a single detection channel. Our results demonstrate on-chip correlation spectroscopy that is less restricted by the signal-to-noise penalty of other spectroscopic approaches, enabling the detection of faint spectral signatures.