Source author record

Shyamsunder Erramilli

Shyamsunder Erramilli appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2021arXiv

Flatfield Ultrafast Imaging with Single-Shot Non-Synchronous Array Photography

We present a method for acquiring a sequence of time-resolved images in a single shot, called Single-Shot Non-Synchronous Array Photography (SNAP). In SNAP, a pulsed laser beam is split by a diffractive optical element into an array of angled beamlets whose illumination fronts remain perpendicular to the optical axis. Different time delays are imparted to each beamlet by an echelon, enabling them to probe a scene in rapid succession. The beamlets are then imaged onto different regions of a camera by a lenslet array. Because the illumination fronts remain flat (head-on) independently of beamlet angle, the temporal resolution of SNAP is fundamentally limited only by the laser pulse duration, akin to a "global shutter" in conventional imaging. We demonstrate SNAP by capturing the evolution of a laser induced plasma filament for 20 frames at an average rate of 4.2 Tfps.

preprint2016arXiv

Perspective: Melanoma diagnosis and monitoring: Sunrise for melanoma therapy but early detection remains in the shade

Melanoma is one of the most dangerous forms of cancer. The five-year survival rate is 98% if it is detected early. However, this rate plummets to 63% for regional disease and 17% when tumors have metastasized, that is, spread to distant sites. Furthermore, the incidence of melanoma has been rising by about 3% per year, whereas the incidence of cancers that are more common is decreasing. A handful of targeted therapies have recently become available that have finally shown real promise for treatment, but for reasons that remain unclear only a fraction of patients respond long term. These drugs often increase survival by only a few months in metastatic patient groups before relapse occurs. More effective treatment may be possible if a diagnosis can be made when the tumor burden is still low. Here, an overview of the current state-of-the-art is provided along with an argument for newer technologies towards early point-of-care diagnosis of melanoma.

preprint2016arXiv

Wireless transfer of power by a 35-GHz metamaterial split-ring resonator rectenna

Wireless transfer of power via high frequency microwave radiation using a miniature split ring resonator rectenna is reported. RF power is converted into DC power by integrating a rectification circuit with the split ring resonator. The near-field behavior of the rectenna is investigated with microwave radiation in the frequency range between 20-40 GHz with a maximum power level of 17 dBm. The observed resonance peaks match those predicted by simulation. Polarization studies show the expected maximum in signal when the electric field is polarized along the edge of the split ring resonator with the gap and minimum for perpendicular orientation. The efficiency of the rectenna is on the order of 1% for a frequency of 37.2 GHz. By using a cascading array of 9 split ring resonators the output power was increased by a factor of 20.

preprint2014arXiv

Field Effect Transistor Nanosensor for Breast Cancer Diagnostics

Silicon nanochannel field effect transistor (FET) biosensors are one of the most promising technologies in the development of highly sensitive and label-free analyte detection for cancer diagnostics. With their exceptional electrical properties and small dimensions, silicon nanochannels are ideally suited for extraordinarily high sensitivity. In fact, the high surface-to-volume ratios of these systems make single molecule detection possible. Further, FET biosensors offer the benefits of high speed, low cost, and high yield manufacturing, without sacrificing the sensitivity typical for traditional optical methods in diagnostics. Top down manufacturing methods leverage advantages in Complementary Metal Oxide Semiconductor (CMOS) technologies, making richly multiplexed sensor arrays a reality. Here, we discuss the fabrication and use of silicon nanochannel FET devices as biosensors for breast cancer diagnosis and monitoring.

preprint2013arXiv

Detection of the melanoma biomarker TROY using silicon nanowire field-effect transistors

Antibody-functionalized silicon nanowire field-effect transistors have been shown to exhibit excellent analyte detection sensitivity enabling sensing of analyte concentrations at levels not readily accessible by other methods. One example where accurate measurement of small concentrations is necessary is detection of serum biomarkers, such as the recently discovered tumor necrosis factor receptor superfamily member TROY (TNFRSF19), which may serve as a biomarker for melanoma. TROY is normally only present in brain but it is aberrantly expressed in primary and metastatic melanoma cells and shed into the surrounding environment. In this study, we show the detection of different concentrations of TROY in buffer solution using top-down fabricated silicon nanowires. We demonstrate the selectivity of our sensors by comparing the signal with that obtained from bovine serum albumin in buffer solution. Both the signal size and the reaction kinetics serve to distinguish the two signals. Using a fast-mixing two-compartment reaction model, we are able to extract the association and dissociation rate constants for the reaction of TROY with the antibody immobilized on the sensor surface.

preprint2013arXiv

Pitchfork Bifurcation and Zharov Splitting in Nonlinear Mid-infrared Photothermal Spectroscopy in a liquid crystal using a Quantum Cascade Laser

We report on the mid-infrared nonlinear photothermal spectrum of the neat liquid crystal 4-Octyl-4'-Cyanobiphenyl (8CB) using a tunable Quantum Cascade Laser (QCL). The nonequilibrium steady state characterized by the nonlinear photothermal infrared response undergoes a supercritical pitchfork bifurcation. The bifurcation, observed in heterodyne two-color pump-probe detection, leads to ultrasharp nonlinear infrared spectra similar to those reported in the visible region. A systematic study of the peak splitting as function of absorbed infrared power shows the bifurcation has a critical exponent of 0.5. The surprising observation of an apparently universal critical exponent in a nonequilibrium state is explained using a simple model reminiscent of mean field theory. Apart from the intrinsic interest for nonequilibrium studies, nonlinear photothermal methods lead to a dramatic narrowing of spectral lines, giving rise to a potential new contrast mechanism for the rapidly emerging new field of mid-infrared microspectroscopy using QCLs.

preprint2008arXiv

Surface modified silicon nanochannel for urea sensing

Silicon nanowires have been surface functionalized with the enzyme urease for biosensor applications to detect and quantify urea concentration. The device is nanofabricated from a silicon on insulator (SOI) wafer with a top down lithography approach. The differential conductance of silicon nanowires can be tuned for optimum performance using the source drain bias voltage, and is sensitive to urea at low concentration. The experimental results show a linear relationship between surface potential change and urea concentration in the range of 0.1 to 0.68 mM. The sensitivity of our devices shows high reproducibility with time and different measurement conditions. The nanowire urea biosensor offers the possibility of high quality, reusable enzyme sensor array integration with silicon based circuits.

preprint1993arXiv

Pressure Induced Hydration Dynamics of Membranes

Pressure-jump initiated time-resolved x-ray diffraction studies of dynamics of the hydration of the hexagonal phase in biological membranes show that (i) the relaxation of the unit cell spacing is non-exponential in time; (ii) the Bragg peaks shift smoothly to their final positions without significant broadening or loss in crystalline order. This suggests that the hydration is not diffusion limited but occurs via a rather homogeneous swelling of the whole lattice, described by power law kinetics with an exponent $ β= 1.3 \pm 0.2$.