Source author record

Mi Hong

Mi Hong appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2013arXiv

Detection of the melanoma biomarker TROY using silicon nanowire field-effect transistors

Antibody-functionalized silicon nanowire field-effect transistors have been shown to exhibit excellent analyte detection sensitivity enabling sensing of analyte concentrations at levels not readily accessible by other methods. One example where accurate measurement of small concentrations is necessary is detection of serum biomarkers, such as the recently discovered tumor necrosis factor receptor superfamily member TROY (TNFRSF19), which may serve as a biomarker for melanoma. TROY is normally only present in brain but it is aberrantly expressed in primary and metastatic melanoma cells and shed into the surrounding environment. In this study, we show the detection of different concentrations of TROY in buffer solution using top-down fabricated silicon nanowires. We demonstrate the selectivity of our sensors by comparing the signal with that obtained from bovine serum albumin in buffer solution. Both the signal size and the reaction kinetics serve to distinguish the two signals. Using a fast-mixing two-compartment reaction model, we are able to extract the association and dissociation rate constants for the reaction of TROY with the antibody immobilized on the sensor surface.

preprint2008arXiv

Surface modified silicon nanochannel for urea sensing

Silicon nanowires have been surface functionalized with the enzyme urease for biosensor applications to detect and quantify urea concentration. The device is nanofabricated from a silicon on insulator (SOI) wafer with a top down lithography approach. The differential conductance of silicon nanowires can be tuned for optimum performance using the source drain bias voltage, and is sensitive to urea at low concentration. The experimental results show a linear relationship between surface potential change and urea concentration in the range of 0.1 to 0.68 mM. The sensitivity of our devices shows high reproducibility with time and different measurement conditions. The nanowire urea biosensor offers the possibility of high quality, reusable enzyme sensor array integration with silicon based circuits.