Source author record

Shuo Pang

Shuo Pang appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
9topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2019arXiv

Deep Learning Cell Imaging through Anderson Localizing Optical Fibre

We demonstrate a deep-learning-based fibre imaging system which can transfer real-time artifact-free cell images through a meter-long Anderson localizing optical fibre. The cell samples are illuminated by an incoherent LED light source. A deep convolutional neural network is applied to the image reconstruction process. The network training uses data generated by a set-up with straight fibre at room temperature (~20 °C) but can be utilized directly for high fidelity reconstruction of cell images that are transported through fibre with a few degrees bend and/or fibre with segments heated up to 50 °C. In addition, cell images located several millimeters away from the bare fibre end can be transported and recovered successfully without the assistance of any distal optics. We further evidence that the trained neural network is able to reconstruct the images of cells which are never used in the training process and feature very different morphology.

preprint2019arXiv

Photon allocation strategy in region-of-interest tomographic imaging

Photon counting detection is a promising approach toward effectively reducing the radiation dose in x-ray computed tomography (CT). Full CT reconstruction from a fraction of the detected photons required by scintillation-based detectors has been demonstrated. Current efforts in photon-counting CT have focused mainly on reconstruction techniques. In medical and industrial x-ray computed tomography (CT) applications, truncated projection from the region-of-interest (ROI) is another effective way of dose reduction, as information from the ROI is usually sufficient for diagnostic purpose. Projection truncation poses an ill-conditioned inverse problem, which can be improved by including projections from the exterior region. However, this trade-off between the interior reconstruction quality and the additional exterior measurement (extra dose) has not been studied. In this manuscript, we explore the number of detected x-ray photons as a new dimension for measurement engineering. Specifically, we design a flexible, photon-efficient measurement strategy for ROI reconstruction by incorporating the photon statistics at extremely low flux level (~10 photons per pixel). The optimized photon-allocation strategy shows 10 ~ 15-fold lower ROI reconstruction error than truncated projections, and 2-fold lower than whole-volume CT scan. Our analysis in few-photon interior tomography could serve as a new framework for dose-efficient, task-specific x-ray image acquisition design.

preprint2019arXiv

Signal retrieval with measurement system knowledge using variational generative model

Signal retrieval from a series of indirect measurements is a common task in many imaging, metrology and characterization platforms in science and engineering. Because most of the indirect measurement processes are well-described by physical models, signal retrieval can be solved with an iterative optimization that enforces measurement consistency and prior knowledge on the signal. These iterative processes are time-consuming and only accommodate a linear measurement process and convex signal constraints. Recently, neural networks have been widely adopted to supersede iterative signal retrieval methods by approximating the inverse mapping of the measurement model. However, networks with deterministic processes have failed to distinguish signal ambiguities in an ill-posed measurement system, and retrieved signals often lack consistency with the measurement. In this work we introduce a variational generative model to capture the distribution of all possible signals, given a particular measurement. By exploiting the known measurement model in the variational generative framework, our signal retrieval process resolves the ambiguity in the forward process, and learns to retrieve signals that satisfy the measurement with high fidelity in a variety of linear and nonlinear ill-posed systems, including ultrafast pulse retrieval, coded aperture compressive video sensing and image retrieval from Fresnel hologram.

preprint2018arXiv

Few-photon computed x-ray imaging

X-ray is a ubiquitous imaging modality in clinical diagnostics and industrial inspections, thanks to its high penetration power. Conventional x-ray imaging system, equipped with energy-integrating detectors, collects approximately 1000 to 10000 counts per pixel to ensure sufficient signal to noise ratio (SNR). The recent development of energy sensitive photon counting detectors opens new possibilities for x-ray imaging at low photon flux. In this letter, we report a novel photon-counting scheme that records the time stamp of individual photons, which follows a negative binomial distribution, and demonstrated the reconstruction based on the few-photon statistics. The projection and tomography reconstruction from measurements of roughly 10 photons shows the potential of using photon counting detectors for dose-efficient x-ray imaging systems.

preprint2012arXiv

Large-field-of-view Chip-scale Talbot-grid-based Fluorescence Microscopy

The fluorescence microscope is one of the most important tools in modern clinical diagnosis and biological science. However, its expense, size and limited field-of-view (FOV) are becoming bottlenecks in key applications such as large-scale phenotyping and low-resource-setting diagnostics. Here we report a low-cost, compact chip-scale fluorescence-imaging platform, termed the Fluorescence Talbot Microscopy (FTM), which utilizes the Talbot self-imaging effect to enable efficient fluorescence imaging over a large and directly-scalable FOV. The FTM prototype has a resolution of 1.2 microns and an FOV of 3.9 mm x 3.5 mm. We demonstrate the imaging capability of FTM on fluorescently labeled breast cancer cells (SK-BR-3) and HEK cells expressing green fluorescent protein.