Source author record

Shuguang Zou

Shuguang Zou appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Topmetal-M: a novel pixel sensor for compact tracking applications

The Topmetal-M is a large area pixel sensor (18 mm * 23 mm) prototype fabricated in a new 130 nm high-resistivity CMOS process in 2019. It contains 400 rows * 512 columns square pixels with the pitch of 40 μm. In Topmetal-M, a novel charge collection method combing the Monolithic Active Pixel Sensor (MAPS) and the Topmetal sensor has been proposed for the first time. Both the ionized charge deposited by the particle in the sensor and along the track over the sensor can be collected. The in-pixel circuit mainly consists of a low-noise charge sensitive amplifier to establish the signal for the energy reconstruction, and a discriminator with a Time-to-Amplitude Converter (TAC) for the Time of Arrival (TOA) measurement. With this mechanism, the trajectory, particle hit position, energy and arrival time of the particle can be measured. The analog signal from each pixel is accessible through time-shared multiplexing over the entire pixel array. This paper will discuss the design and preliminary test results of the Topmetal-M sensor.

preprint2016arXiv

Test of \textit{Topmetal-${II}^-$} In Liquid Nitrogen For Cryogenic Temperature TPCs

\textit{Topmetal-${II}^-$} is a highly pixelated direct charge sensor that contains a 72${\times}$72 pixel array of 83$μ$m pitch size. The key feature of \textit{Topmetal-${II}^-$} is that it can directly collect charges via metal nodes of each pixel to form two-dimensional images of charge cloud distributions. \textit{Topmetal-${II}^-$} was proved to measure charged particles without amplification at room temperature. To measure its performance at cryogenic temperature, a \textit{Topmetal-${II}^-$} sensor is embedded into a liquid nitrogen dewar. The results presented in this paper show that \textit{Topmetal-${II}^-$} can also operate well at this low temperature with a noise (ENC) of 12 e$^-$ lower than that at room temperature (13 e$^-$). From the noise perspective, \textit{Topmetal-${II}^-$} is a promising candidate for the next generation readout of liquid argon and xenon Time Projection Chamber (TPC) used in experiments searching for neutrinoless double beta decay and dark matter.