Source author record

Hua Pei

Hua Pei appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

Topmetal-M: a novel pixel sensor for compact tracking applications

The Topmetal-M is a large area pixel sensor (18 mm * 23 mm) prototype fabricated in a new 130 nm high-resistivity CMOS process in 2019. It contains 400 rows * 512 columns square pixels with the pitch of 40 μm. In Topmetal-M, a novel charge collection method combing the Monolithic Active Pixel Sensor (MAPS) and the Topmetal sensor has been proposed for the first time. Both the ionized charge deposited by the particle in the sensor and along the track over the sensor can be collected. The in-pixel circuit mainly consists of a low-noise charge sensitive amplifier to establish the signal for the energy reconstruction, and a discriminator with a Time-to-Amplitude Converter (TAC) for the Time of Arrival (TOA) measurement. With this mechanism, the trajectory, particle hit position, energy and arrival time of the particle can be measured. The analog signal from each pixel is accessible through time-shared multiplexing over the entire pixel array. This paper will discuss the design and preliminary test results of the Topmetal-M sensor.

preprint2016arXiv

Test of \textit{Topmetal-${II}^-$} In Liquid Nitrogen For Cryogenic Temperature TPCs

\textit{Topmetal-${II}^-$} is a highly pixelated direct charge sensor that contains a 72${\times}$72 pixel array of 83$μ$m pitch size. The key feature of \textit{Topmetal-${II}^-$} is that it can directly collect charges via metal nodes of each pixel to form two-dimensional images of charge cloud distributions. \textit{Topmetal-${II}^-$} was proved to measure charged particles without amplification at room temperature. To measure its performance at cryogenic temperature, a \textit{Topmetal-${II}^-$} sensor is embedded into a liquid nitrogen dewar. The results presented in this paper show that \textit{Topmetal-${II}^-$} can also operate well at this low temperature with a noise (ENC) of 12 e$^-$ lower than that at room temperature (13 e$^-$). From the noise perspective, \textit{Topmetal-${II}^-$} is a promising candidate for the next generation readout of liquid argon and xenon Time Projection Chamber (TPC) used in experiments searching for neutrinoless double beta decay and dark matter.

preprint2014arXiv

Development of a highly pixelated direct charge sensor, Topmetal-I, for ionizing radiation imaging

Using industrial standard 0.35μm CMOS Integrated Circuit process, we realized a highly pixelated sensor that directly collects charge via metal nodes placed on the top of each pixel and forms two dimensional images of charge cloud distribution. The first version, Topmetal-I, features a 64x64 pixel array of 80μm pitch size. Direct charge calibration reveals an average capacitance of 210fF per pixel. The charge collection noise is near the thermal noise limit. With the readout, individual pixel channels exhibit a most probable equivalent noise charge of 330e-.

preprint2011arXiv

Jet Studies in STAR via 2+1 Correlations

This paper reports analysis on jet-medium interactions and di-jet surface emission bias at RHIC, based on a new multi-hadron correlation technique called \texttt{2+1} where back-to-back high $p_{T}$ hadron triggers work as proxy of di-jets. In contrast with traditional correlations with single triggers, the associated hadron distributions and spectra at both trigger sides show no evident modification from d+Au to central Au+Au collisions. This observation stands for both cases when triggers pairs are symmetric($p_T>$5GeV/$c$ vs. $p_T>$4GeV/$c$) or asymmetric($E_T>$10GeV/$c$ vs. $p_T>$4GeV/$c$).

preprint2011arXiv

Probing Hot and Dense Nuclear Matter with Particle Correlations and Jets at RHIC

The hot and dense medium created at RHIC, called Quark and Gluon Plasma (QGP) has been a hot topic in the last ten years. Due to the high multiplicities in such heavy-ion collision events, particle correlations using either trigger particles, or fully-reconstructed jets, become not only useful but necessary, in addition to the single particle observables. In this paper the most recent work studying this medium will be shown, including both on bulk properties and tagged events.