Source author record

Shisong Li

Shisong Li appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

17works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

17 published item(s)

preprint2022arXiv

Magnetic Uncertainties for Compact Kibble Balances: An Investigation

The Kibble balance has become one of the major instruments for realizing the mass unit, the kilogram, in the revised international system of units (SI). Researchers at about a dozen national metrology institutes are actively working with Kibble balances that are capable of weighing masses with nominal values from 10g to 1kg. In the future, the design of smaller Kibble balances will play a more significant role. Smaller Kibble balances require smaller magnet systems, and here we investigate the scaling of systematic uncertainties with the size of the magnet system. We describe the size dependence of three magnetic effects: the coil-inductance effect, the yoke nonlinear effect, and the thermal effect. The analysis shows that the relative systematic effects become increasingly larger with smaller sizes. For small magnets the thermal effects become dominant and, hence, a good thermal design is imperative.

preprint2021arXiv

A Two-Stage Wavelet Decomposition Method for Instantaneous Power Quality Indices Estimation Considering Interharmonics and Transient Disturbances

As the complexity increases in modern power systems, power quality analysis considering interharmonics has become a challenging and important task. This paper proposes a novel decomposition and estimation method for instantaneous power quality indices (PQIs) monitoring in single-phase and three-phase systems with interharmonics and transient disturbances. To separate the interharmonic components, a set of new scaling filter and wavelet filter with narrow transition bands are designed for the undecimated wavelet packet transform (UWPT). Further, a two-stage decomposition method for multi-tone voltage and current signals is proposed. The Hilbert transform (HT) is applied to calculate the instantaneous amplitude and phase of each frequency component, which accordingly allows the monitoring of different PQI parameters. Numerical tests are conducted to check the performance of the proposed method. The test results show that compared to other conventional approaches, instantaneous PQIs estimated by the proposed method present significant advances for tracking transitory changes in power systems, and could be considered as a helpful tool for high-accuracy PQ detections.

preprint2021arXiv

Resolution of the paradox of the diamagnetic effect on the Kibble coil

Employing very simple electro-mechanical principles known from classical physics, the Kibble balance establishes a very precise and absolute link between quantum electrical standards and macroscopic mass or force measurements. The success of the Kibble balance, in both determining fundamental constants ($h$, $N_A$, $e$) and realizing a quasi-quantum mass in the 2019 newly revised International System of Units, relies on the perfection of Maxwell's equations and the symmetry they describe between Lorentz's force and Faraday's induction, a principle and a symmetry stunningly demonstrated in the weighing and velocity modes of Kibble balances to within $1\times10^{-8}$, with nothing but imperfect wires and magnets. However, recent advances in the understanding of the current effect in Kibble balances reveal a troubling paradox. A diamagnetic effect, a force that does not cancel between mass-on and mass-off measurement, is challenging balance maker's assumptions of symmetry at levels that are almost two orders of magnitude larger than the reported uncertainties. The diamagnetic effect, if it exists, shows up in weighing mode without a readily apparent reciprocal effect in the velocity mode, begging questions about systematic errors at the very foundation of the new measurement system. The hypothetical force is caused by the coil current changing the magnetic field, producing an unaccounted force that is systematically modulated with the weighing current. Here we show that this diamagnetic force exists, but the additional force does not change the equivalence between weighing and velocity measurements. We reveal the unexpected way that symmetry is preserved and show that for typical materials and geometries the total relative effect on the measurement is $\approx 1\times10^{-9}$.

preprint2021arXiv

The irony of the magnet system for Kibble balances -- a review

The magnet system is an essential component of the Kibble balance, a device that is used to realize the unit of mass. It is the source of the magnetic flux, and its importance is captured in the geometric factor $Bl$. Ironically, the $Bl$ factor cancels out and does not appear in the final Kibble equation. Nevertheless, care must be taken to design and build the magnet system because the cancellation is perfect only if the $Bl$ is the same in both modes: the weighing and velocity mode. This review provides the knowledge necessary to build a magnetic circuit for the Kibble balance. In addition, this article discusses the design considerations, parameter optimizations, practical adjustments to the finished product, and an assessment of systematic uncertainties associated with the magnet system.

preprint2020arXiv

A Simple Improvement for Permanent Magnet Systems for Kibble Balances: More Flat Field at Almost No Cost

Permanent magnets together with yokes to concentrate the magnetic flux into a cylindrical air-gap are widely employed in Kibble balances. These experiments require a uniform magnetic flux density along a vertical path, typically a substantial fraction of the length of the air-gap. Fringe fields that are present at both ends of the air-gap limit the region where the flux density does not change more than a certain relative fraction (here: $5\times 10^{-4}$) of the flux density in the center of the magnet system. By simply adding an iron ring with a rectangular cross-section to the inner yoke at each end of the air gap, the effects of the fringe fields can be counteracted, and, hence, the length of the region, where the flux density remains within a given tolerance band is increased. Compared to the alternative, employing a taller magnet, the proposed method yields a magnet system with an extended region of a uniform field without significantly increasing the mass of the magnet system. Potential applications include compact and table-top Kibble balances. We investigate possible adverse effects on the performance of the magnet system caused by the additional rings: magnetic field strength, coil-current effect, and a dependence of the radial field on the radial position in the field. No substantial disadvantage was found. Instead, the method presented here outperformed previously suggested methods to improve the radial dependence of the radial field, e.g., shorter outer yoke. In summary, adding rings to the inner yoke improves the uniformity of the field without a detrimental effect to function, cost, and form factor of the magnet system.

preprint2020arXiv

From $μ_0$ to $e$: A Survey of Major Impacts for Electrical Measurements in Recent SI Revision

A milestone revision of the International System of Units (SI) was made at the 26th General Conference on Weights and Measures that four of the seven SI base units, i.e. kilogram, ampere, kelvin, and mole, are redefined by fundamental physical constants of nature. The SI base unit founding the electrical measurement activities, i.e. ampere, is defined by fixing the numerical value of the elementary charge to $e=1.602\,176\,634\times10^{-19}$C. For electrical measurement, several major adjustments, mostly positive, are involved in this SI revision. In this paper, the main impacts of the new SI for electrical measurement activities are surveyed under the new framework.

preprint2016arXiv

A Five-Freedom Active Damping and Alignment Device Used in the Joule Balance

Damping devices are necessary for suppressing the undesired coil motions in the watt/joule balance. In this paper, an active electromagnetic damping device, located outside the main magnet, is introduced in the joule balance project. The presented damping device can be used in both dynamic and static measurement modes. With the feedback from a detection system, five degrees of freedom of the coil, i.e. the horizontal displacement $x$, $y$ and the rotation angles $θ_x$, $θ_y$, $θ_z$, can be controlled by the active damping device. Hence, two functions, i.e. suppressing the undesired coil motions and reducing the misalignment error, can be realized with this active damping device. The principle, construction and performance of the proposed active damping device are presented.

preprint2016arXiv

Designing Model and Optimization of the Permanent Magnet for Joule Balance NIM-2

Permanent magnets with yokes are widely used in the watt and joule balances to measure the Planck constant for the forthcoming redefinition of the unit of mass, the kilogram. Recently, a permanent magnet system has been in consideration for a further practice of NIM-2, the generalized joule balance. In this paper, an analytical model to design the permanent magnet system is presented. The presented model can be solved to obtain the preliminary parameters and then is used as guidance for FEA software to optimize the parameters of such magnetic system. As an instance for the application of the designing model, the design of the permanent magnet system for NIM-2 is described and the special design of opening shape makes the misalignment of the top and middle yokes has little influence on the vertical component of the magnetic field.

preprint2015arXiv

A discussion of $Bl$ conservation on a two dimensional magnetic field plane in watt balances

The watt balance is an experiment being pursued in national metrology institutes for precision determination of the Planck constant $h$. In watt balances, the $1/r$ magnetic field, expected to generate a geometrical factor $Bl$ independent to any coil horizontal displacement, can be created by a strict two dimensional, symmetric (horizontal $r$ and vertical $z$) construction of the magnet system. In this paper, we present an analytical understanding of magnetic field distribution when the $r$ symmetry of the magnet is broken and the establishment of the $Bl$ conservation is shown. By using either Gauss's law on magnetism with monopoles or conformal transformations, we extend the $Bl$ conservation to arbitrary two dimensional magnetic planes where the vertical magnetic field component equals zero. The generalized $Bl$ conservation allows a relaxed physical alignment criteria for watt balance magnet systems.

preprint2015arXiv

An analytical algorithm for 3D magnetic field mapping of a watt balance magnet

A yoke-based permanent magnet, which has been employed in many watt balances at national metrology institutes, is supposed to generate strong and uniform magnetic field in an air gap in the radial direction. However, in reality the fringe effect due to the finite height of the air gap will introduce an undesired vertical magnetic component to the air gap, which should either be measured or modeled towards some optimizations of the watt balance. A recent publication, i.e., {\it Metrologia} 52(4) 445 [1], presented a full field mapping method, which in theory will supply useful information for profile characterization and misalignment analysis. This article is an additional material of [1], which develops a different analytical algorithm to represent the 3D magnetic field of a watt balance magnet based on only one measurement for the radial magnetic flux density along the vertical direction, $B_r(z)$. The new algorithm is based on the electromagnetic nature of the magnet, which has a much better accuracy.

preprint2015arXiv

Coils and the Electromagnet Used in the Joule Balance at the NIM

In the joule balance developed at National Institute of Metrology (NIM), the dynamic phase of a watt balance is replaced by the mutual inductance measurement in an attempt to provide an alternative method for the kg redefinition. But for this method a rather large current in the exciting coil, is needed to offer the necessary magnetic field in the force weighing phase, and the coil heating becomes an important uncertainty source. To reduce coil heating, a new coil system, in which a ferromagnetic material is used to increase the magnetic field was designed recently. But adopting the ferromagnetic material brings the difficulty from the nonlinear characteristic of material. This problem can be removed by measuring the magnetic flux linkage difference of the suspended coil at two vertical positions directly to replace the mutual inductance parameter. Some systematic effects of this magnet are discussed.

preprint2014arXiv

A nonlinearity in permanent-magnet systems used in watt balances

Watt balances are used to measure the Planck constant and will be used in the future to realize mass at the kilogram level. They increasingly rely on permanent magnet systems to generate the magnetic flux. It has been known that the weighing current might effect the magnetization state of the permanent magnetic system used in these systems causing a systematic bias that can lead to an error in the result if not accounted for. In this article a simple model explaining the effect of the weighing current on the yoke of the magnet is developed. This model leads to a nonlinear dependence of the magnetic flux density in the gap that is proportional to the squared value of the coil current. The effect arises from changing the reluctance of the yoke by the additional field produced by the coil. Our analysis shows that the effect depends on the width of the air gap, the magnetic flux density in the air gap, and the $BH$ curve of the yoke material. Suggestions to reduce the nonlinear effect are discussed.

preprint2014arXiv

Construction, Measurement, Shimming, and Performance of the NIST-4 Magnet System

The magnet system is one of the key elements of a watt balance. For the new watt balance currently under construction at the National Institute of Standards and Technology, a permanent magnet system was chosen. We describe the detailed construction of the magnet system, first measurements of the field profile, and shimming techniques that were used to achieve a flat field profile. The relative change of the radial magnetic flux density is less than $10^{-4}$ over a range of 5 cm. We further characterize the most important aspects of the magnet and give order of magnitude estimates for several systematic effects that originate from the magnet system.

preprint2014arXiv

Field representation of a watt balance magnet by partial profile measurements

Permanent magnets with high-permeability yokes have been widely used in watt balances for supplying a robust and strong magnetic field at the coil position. Subjected to the mechanical realization, only several $B_r(z)$ (radial magnetic field along the vertical direction) profiles can be measured by coils for field characterization. In this article, we present an algorithm that can construct the global magnetic field of the air gap based on $N(N\geq1)$ additional measurements of $B_r(z)$ profiles. The proposed algorithm is realized by polynomially estimating the $B_z(r)$ function with analysis of basic relations between two magnetic components in air gap, i.e., $B_r(r,z)$ and $B_z(r,z)$, following the Maxwell's equations. The algorithm, verified by FEM simulations, can characterize the three-dimensional contribution of the magnetic field for a watt balance magnet with acceptable accuracy, which would supply basic field parameters for alignment and misalignment corrections.

preprint2014arXiv

Progress on accurate measurement of the Planck constant: watt balance and counting atoms

The Planck constant $h$ is one of the most significant constants in quantum physics. Recently, the precision measurement of the numeral value of $h$ has been a hot issue due to its important role in establishment for both a new SI and a revised fundamental physical constant system. Up to date, two approaches, the watt balance and counting atoms, have been employed to determine the Planck constant at a level of several parts in $10^8$. In this paper, the principle and progress on precision measurement of the Planck constant using watt balance and counting atoms at national metrology institutes are reviewed. Further improvements for the Planck constant determination and possible developments of a revised physical constant system in future are discussed.

preprint2014arXiv

The Improvement of Joule Balance NIM-1 and the Design of New Joule Balance NIM-2

The development of the joule balance method to measure the Planck constant, in support of the redefinition of the kilogram, has been going on at the National Institute of Metrology of China (NIM) since 2007. The first prototype has been built to check the feasibility of the principle. In 2011, the relative uncertainty of the Planck constant measurement at NIM is $7.7\times10^{-5}$. Self-heating of the coils, swing of the coil, are the main uncertainty contributions. Since 2012, some improvements have been made to reduce these uncertainties. The relative uncertainty of the joule balance is reduced to $7.2\times10^{-6}$ at present. The Planck constant measured with the joule balance is $h=6.6261041(470)\times10^{-34}$Js. The relative difference between the determined h and the CODATA2010 recommendation value is $5\times10^{-6}$. Further improvements are still being carried out on the NIM-1 apparatus. At the same time, the design and construction of a brand new and compact joule balance NIM-2 are also in progress and presented here.

preprint2014arXiv

The NIM Inertial Mass Measurement Project

An inertial mass measurement project, which is expected to precisely measure the Planck constant, $h$, for possible comparisons with known gravitational mass measurement projects, e.g., the watt balance and the Avogadro project, is being carried out at the National Institute of Metrology, China. The principle, apparatus, and experimental investigations of the inertial mass measurement are presented. The prototype of the experiment and the Planck constant with relative uncertainty of several parts in $10^{4}$ have been achieved for principle testing.