Researcher profile

Shisong Li

Shisong Li contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Magnetic Uncertainties for Compact Kibble Balances: An Investigation

The Kibble balance has become one of the major instruments for realizing the mass unit, the kilogram, in the revised international system of units (SI). Researchers at about a dozen national metrology institutes are actively working with Kibble balances that are capable of weighing masses with nominal values from 10g to 1kg. In the future, the design of smaller Kibble balances will play a more significant role. Smaller Kibble balances require smaller magnet systems, and here we investigate the scaling of systematic uncertainties with the size of the magnet system. We describe the size dependence of three magnetic effects: the coil-inductance effect, the yoke nonlinear effect, and the thermal effect. The analysis shows that the relative systematic effects become increasingly larger with smaller sizes. For small magnets the thermal effects become dominant and, hence, a good thermal design is imperative.

preprint2021arXiv

A Two-Stage Wavelet Decomposition Method for Instantaneous Power Quality Indices Estimation Considering Interharmonics and Transient Disturbances

As the complexity increases in modern power systems, power quality analysis considering interharmonics has become a challenging and important task. This paper proposes a novel decomposition and estimation method for instantaneous power quality indices (PQIs) monitoring in single-phase and three-phase systems with interharmonics and transient disturbances. To separate the interharmonic components, a set of new scaling filter and wavelet filter with narrow transition bands are designed for the undecimated wavelet packet transform (UWPT). Further, a two-stage decomposition method for multi-tone voltage and current signals is proposed. The Hilbert transform (HT) is applied to calculate the instantaneous amplitude and phase of each frequency component, which accordingly allows the monitoring of different PQI parameters. Numerical tests are conducted to check the performance of the proposed method. The test results show that compared to other conventional approaches, instantaneous PQIs estimated by the proposed method present significant advances for tracking transitory changes in power systems, and could be considered as a helpful tool for high-accuracy PQ detections.

preprint2021arXiv

Resolution of the paradox of the diamagnetic effect on the Kibble coil

Employing very simple electro-mechanical principles known from classical physics, the Kibble balance establishes a very precise and absolute link between quantum electrical standards and macroscopic mass or force measurements. The success of the Kibble balance, in both determining fundamental constants ($h$, $N_A$, $e$) and realizing a quasi-quantum mass in the 2019 newly revised International System of Units, relies on the perfection of Maxwell's equations and the symmetry they describe between Lorentz's force and Faraday's induction, a principle and a symmetry stunningly demonstrated in the weighing and velocity modes of Kibble balances to within $1\times10^{-8}$, with nothing but imperfect wires and magnets. However, recent advances in the understanding of the current effect in Kibble balances reveal a troubling paradox. A diamagnetic effect, a force that does not cancel between mass-on and mass-off measurement, is challenging balance maker's assumptions of symmetry at levels that are almost two orders of magnitude larger than the reported uncertainties. The diamagnetic effect, if it exists, shows up in weighing mode without a readily apparent reciprocal effect in the velocity mode, begging questions about systematic errors at the very foundation of the new measurement system. The hypothetical force is caused by the coil current changing the magnetic field, producing an unaccounted force that is systematically modulated with the weighing current. Here we show that this diamagnetic force exists, but the additional force does not change the equivalence between weighing and velocity measurements. We reveal the unexpected way that symmetry is preserved and show that for typical materials and geometries the total relative effect on the measurement is $\approx 1\times10^{-9}$.

preprint2021arXiv

The irony of the magnet system for Kibble balances -- a review

The magnet system is an essential component of the Kibble balance, a device that is used to realize the unit of mass. It is the source of the magnetic flux, and its importance is captured in the geometric factor $Bl$. Ironically, the $Bl$ factor cancels out and does not appear in the final Kibble equation. Nevertheless, care must be taken to design and build the magnet system because the cancellation is perfect only if the $Bl$ is the same in both modes: the weighing and velocity mode. This review provides the knowledge necessary to build a magnetic circuit for the Kibble balance. In addition, this article discusses the design considerations, parameter optimizations, practical adjustments to the finished product, and an assessment of systematic uncertainties associated with the magnet system.

preprint2020arXiv

A Simple Improvement for Permanent Magnet Systems for Kibble Balances: More Flat Field at Almost No Cost

Permanent magnets together with yokes to concentrate the magnetic flux into a cylindrical air-gap are widely employed in Kibble balances. These experiments require a uniform magnetic flux density along a vertical path, typically a substantial fraction of the length of the air-gap. Fringe fields that are present at both ends of the air-gap limit the region where the flux density does not change more than a certain relative fraction (here: $5\times 10^{-4}$) of the flux density in the center of the magnet system. By simply adding an iron ring with a rectangular cross-section to the inner yoke at each end of the air gap, the effects of the fringe fields can be counteracted, and, hence, the length of the region, where the flux density remains within a given tolerance band is increased. Compared to the alternative, employing a taller magnet, the proposed method yields a magnet system with an extended region of a uniform field without significantly increasing the mass of the magnet system. Potential applications include compact and table-top Kibble balances. We investigate possible adverse effects on the performance of the magnet system caused by the additional rings: magnetic field strength, coil-current effect, and a dependence of the radial field on the radial position in the field. No substantial disadvantage was found. Instead, the method presented here outperformed previously suggested methods to improve the radial dependence of the radial field, e.g., shorter outer yoke. In summary, adding rings to the inner yoke improves the uniformity of the field without a detrimental effect to function, cost, and form factor of the magnet system.

preprint2020arXiv

From $μ_0$ to $e$: A Survey of Major Impacts for Electrical Measurements in Recent SI Revision

A milestone revision of the International System of Units (SI) was made at the 26th General Conference on Weights and Measures that four of the seven SI base units, i.e. kilogram, ampere, kelvin, and mole, are redefined by fundamental physical constants of nature. The SI base unit founding the electrical measurement activities, i.e. ampere, is defined by fixing the numerical value of the elementary charge to $e=1.602\,176\,634\times10^{-19}$C. For electrical measurement, several major adjustments, mostly positive, are involved in this SI revision. In this paper, the main impacts of the new SI for electrical measurement activities are surveyed under the new framework.