Source author record

Zhengkun Li

Zhengkun Li appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2022arXiv

Honour Thesis: A Joint Value at Risk and Expected Shortfall Combination Framework and its Applications in the Cryptocurrency Market

Value at risk and expected shortfall are increasingly popular tail risk measures in the financial risk management field. Both academia and financial institutions are working to improve tail risk forecasts in order to meet the requirements of the Basel Capital Accord; it states that one purpose of risk management and measuring risk accuracy is, since extreme movements cannot always be avoided, financial institutions can prepare for these extreme returns by capital allocation, and putting aside the appropriate amount of capital so as to avoid default in times of extreme price or index movements. Forecast combination has drawn much attention, as a combined forecast can outperform the individual forecasts under certain conditions. We propose two methodology, one is a semiparametric combination framework that can jointly produce combined value at risk and expected shortfall forecasts, another one is a parametric regression framework named as Quantile-ES regression that can produce combined expected shortfall forecasts. The favourability of the semiparametric combination framework has been presented via an empirical study - application in cryptocurrency markets with high-frequency data where the necessity of risk management application increases as the cryptocurrency market becomes more popular and mature. Additionally, the general framework of the parametric Quantile-ES regression has been presented via a simulation study, whereas it still need to be improved in the future. The contributions of this work include but are not limited to the enabling of the combination of expected shortfall forecasts and the application of risk management procedures in the cryptocurrency market with high-frequency data.

preprint2016arXiv

A Five-Freedom Active Damping and Alignment Device Used in the Joule Balance

Damping devices are necessary for suppressing the undesired coil motions in the watt/joule balance. In this paper, an active electromagnetic damping device, located outside the main magnet, is introduced in the joule balance project. The presented damping device can be used in both dynamic and static measurement modes. With the feedback from a detection system, five degrees of freedom of the coil, i.e. the horizontal displacement $x$, $y$ and the rotation angles $θ_x$, $θ_y$, $θ_z$, can be controlled by the active damping device. Hence, two functions, i.e. suppressing the undesired coil motions and reducing the misalignment error, can be realized with this active damping device. The principle, construction and performance of the proposed active damping device are presented.

preprint2016arXiv

Designing Model and Optimization of the Permanent Magnet for Joule Balance NIM-2

Permanent magnets with yokes are widely used in the watt and joule balances to measure the Planck constant for the forthcoming redefinition of the unit of mass, the kilogram. Recently, a permanent magnet system has been in consideration for a further practice of NIM-2, the generalized joule balance. In this paper, an analytical model to design the permanent magnet system is presented. The presented model can be solved to obtain the preliminary parameters and then is used as guidance for FEA software to optimize the parameters of such magnetic system. As an instance for the application of the designing model, the design of the permanent magnet system for NIM-2 is described and the special design of opening shape makes the misalignment of the top and middle yokes has little influence on the vertical component of the magnetic field.

preprint2015arXiv

An analytical algorithm for 3D magnetic field mapping of a watt balance magnet

A yoke-based permanent magnet, which has been employed in many watt balances at national metrology institutes, is supposed to generate strong and uniform magnetic field in an air gap in the radial direction. However, in reality the fringe effect due to the finite height of the air gap will introduce an undesired vertical magnetic component to the air gap, which should either be measured or modeled towards some optimizations of the watt balance. A recent publication, i.e., {\it Metrologia} 52(4) 445 [1], presented a full field mapping method, which in theory will supply useful information for profile characterization and misalignment analysis. This article is an additional material of [1], which develops a different analytical algorithm to represent the 3D magnetic field of a watt balance magnet based on only one measurement for the radial magnetic flux density along the vertical direction, $B_r(z)$. The new algorithm is based on the electromagnetic nature of the magnet, which has a much better accuracy.

preprint2015arXiv

Coils and the Electromagnet Used in the Joule Balance at the NIM

In the joule balance developed at National Institute of Metrology (NIM), the dynamic phase of a watt balance is replaced by the mutual inductance measurement in an attempt to provide an alternative method for the kg redefinition. But for this method a rather large current in the exciting coil, is needed to offer the necessary magnetic field in the force weighing phase, and the coil heating becomes an important uncertainty source. To reduce coil heating, a new coil system, in which a ferromagnetic material is used to increase the magnetic field was designed recently. But adopting the ferromagnetic material brings the difficulty from the nonlinear characteristic of material. This problem can be removed by measuring the magnetic flux linkage difference of the suspended coil at two vertical positions directly to replace the mutual inductance parameter. Some systematic effects of this magnet are discussed.

preprint2014arXiv

Progress on accurate measurement of the Planck constant: watt balance and counting atoms

The Planck constant $h$ is one of the most significant constants in quantum physics. Recently, the precision measurement of the numeral value of $h$ has been a hot issue due to its important role in establishment for both a new SI and a revised fundamental physical constant system. Up to date, two approaches, the watt balance and counting atoms, have been employed to determine the Planck constant at a level of several parts in $10^8$. In this paper, the principle and progress on precision measurement of the Planck constant using watt balance and counting atoms at national metrology institutes are reviewed. Further improvements for the Planck constant determination and possible developments of a revised physical constant system in future are discussed.

preprint2014arXiv

The Improvement of Joule Balance NIM-1 and the Design of New Joule Balance NIM-2

The development of the joule balance method to measure the Planck constant, in support of the redefinition of the kilogram, has been going on at the National Institute of Metrology of China (NIM) since 2007. The first prototype has been built to check the feasibility of the principle. In 2011, the relative uncertainty of the Planck constant measurement at NIM is $7.7\times10^{-5}$. Self-heating of the coils, swing of the coil, are the main uncertainty contributions. Since 2012, some improvements have been made to reduce these uncertainties. The relative uncertainty of the joule balance is reduced to $7.2\times10^{-6}$ at present. The Planck constant measured with the joule balance is $h=6.6261041(470)\times10^{-34}$Js. The relative difference between the determined h and the CODATA2010 recommendation value is $5\times10^{-6}$. Further improvements are still being carried out on the NIM-1 apparatus. At the same time, the design and construction of a brand new and compact joule balance NIM-2 are also in progress and presented here.

preprint2014arXiv

The NIM Inertial Mass Measurement Project

An inertial mass measurement project, which is expected to precisely measure the Planck constant, $h$, for possible comparisons with known gravitational mass measurement projects, e.g., the watt balance and the Avogadro project, is being carried out at the National Institute of Metrology, China. The principle, apparatus, and experimental investigations of the inertial mass measurement are presented. The prototype of the experiment and the Planck constant with relative uncertainty of several parts in $10^{4}$ have been achieved for principle testing.