Source author record

Shantanu Singh

Shantanu Singh appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2026arXiv

Anti-reflection coatings for highly anisotropic materials in the mid infrared

We develop and optimize thin anti-reflection coatings (ARCs) for highly anisotropic materials in the mid infrared. Unlike conventional ARCs that assume nearly isotropic refractive indices, this work fully integrates the anisotropic nature of materials into the design process. We describe two designs of thin ARCs for highly anisotropic materials: a single form-birefringent layer, and a planar bilayer. We realized the planar bilayer ARC experimentally, demonstrating excellent mid-infrared anti-reflectance across over a broad range of angles for all polarizations.

preprint2014arXiv

Analysis of Femoral Components of Cemented Total Hip- Arthroplasty

In cemented Total Hip Arthroplasty (THA), material chosen for femoral stem and cross section of stem itself, proved to be critical parameters for, stress distribution in the femoral components, interfacial stresses and micro movements. Titanium alloy (Ti6Al4V), when used as a material for femoral stem, recorded large displacement as compared to Chromium alloy (CoCrMo) stems. This large displacement in case of Ti6Al4V caused the stem to bend inside the cement mantle, thus destroying it. Thus, CoCrMo proved to be a better in cemented THA. Failure in THA may occur at cement-stem or cement-bone interface, thus interfacial stresses and micro movements were analysed in the present study. Comparison between trapezium and circular cross section showed that, femoral stem with trapezium cross section underwent lesser amount of sliding and debonding, at both interfaces, as compared to circular cross section. Moreover, trapezium cross section also generated lower peak stresses in femoral stem and cortical femur. The present study also took into account, effect of diameter of femur head. A 36mm diameter femur head generated lower peak stress in acetabulum liner and arrested dislocation. Metallic femur head was coupled with a liner made of cross linked polyethylene (XLPE). This material experiences almost negligible wear when compared to typical metallic and polyethylene liners, and unlike metallic liner, it is non-carcinogenic.