Source author record

Sayeed Shafayet Chowdhury

Sayeed Shafayet Chowdhury appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
11topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2020arXiv

Anomaly Detection in Unsupervised Surveillance Setting Using Ensemble of Multimodal Data with Adversarial Defense

Autonomous aerial surveillance using drone feed is an interesting and challenging research domain. To ensure safety from intruders and potential objects posing threats to the zone being protected, it is crucial to be able to distinguish between normal and abnormal states in real-time. Additionally, we also need to consider any device malfunction. However, the inherent uncertainty embedded within the type and level of abnormality makes supervised techniques less suitable since the adversary may present a unique anomaly for intrusion. As a result, an unsupervised method for anomaly detection is preferable taking the unpredictable nature of attacks into account. Again in our case, the autonomous drone provides heterogeneous data streams consisting of images and other analog or digital sensor data, all of which can play a role in anomaly detection if they are ensembled synergistically. To that end, an ensemble detection mechanism is proposed here which estimates the degree of abnormality of analyzing the real-time image and IMU (Inertial Measurement Unit) sensor data in an unsupervised manner. First, we have implemented a Convolutional Neural Network (CNN) regression block, named AngleNet to estimate the angle between a reference image and current test image, which provides us with a measure of the anomaly of the device. Moreover, the IMU data are used in autoencoders to predict abnormality. Finally, the results from these two pipelines are ensembled to estimate the final degree of abnormality. Furthermore, we have applied adversarial attack to test the robustness and security of the proposed approach and integrated defense mechanism. The proposed method performs satisfactorily on the IEEE SP Cup-2020 dataset with an accuracy of 97.8%. Additionally, we have also tested this approach on an in-house dataset to validate its robustness.

preprint2020arXiv

Numerical Analysis of a Highly Sensitive Surface Plasmon Resonance Sensor for SARS-CoV-2 Detection

In this paper, we propose a surface plasmon resonance (SPR) structure based on Kretschmann configuration incorporating layers of Silicon and BaTiO$_3$ on top of Ag for real-time detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) using thiol tethered DNA as a ligand. Extensive numerical analysis based on transfer matrix theory as well as finite-difference time-domain (FDTD) technique has been performed to characterize the sensor response considering sensitivity, full width at half maxima, and minimum reflection. About 7.6 times enhanced sensitivity has been obtained using the proposed architecture for SARS-CoV-2 detection, compared to the basic Kretschmann configuration. Notably, the structure provides consistent enhancement over other competitive SPR structures for both angular and wavelength interrogations with a figure-of-merit of 692.28. Additionally, we repeated simulations for various ligate-ligand pairs to assess the range of applicability and robust performance improvement has been observed. As a result, the proposed sensor design provides a suitable configuration for highly sensitive, rapid, non-invasive biosensing which can be useful if adopted in experimental sensing protocols.

preprint2020arXiv

Optimization of Surface Plasmon Resonance Biosensor for Analysis of Lipid Molecules

Surface Plasmon Resonance (SPR) is an important bio-sensing technique for real-time label-free detection. However, it is pivotal to optimize various parameters of the sensor configuration for efficient and highly sensitive sensing. To that effect, we focus on optimizing two different SPR structures -- the basic Kretschmann configuration and narrow groove grating. Our analysis aims to detect two different types of lipids known as phospholipid and eggyolk, which are used as analyte (sensing layer) and two different types of proteins namely tryptophan and bovine serum albumin (BSA) are used as ligand (binding site). For both the configurations, we investigate all possible lipid-protein combinations to understand the effect of various parameters on sensitivity, minimum reflectivity and full width half maximum (FWHM). Lipids are the structural building block of cell membranes and mutation of these layers by virus and bacteria is one the prime reasons of many diseases in our body. Hence, improving the performance of a SPR sensor to detect very small change in lipid holds immense significance. We use finite-difference time-domain (FDTD) technique to perform quantitative analysis to get an optimized structure. We find that sensitivity increases when lipid concentration is increased and it is the highest (21.95 degree/RIU) for phospholipid and tryptophan combination when metal and lipid layer thickness are 45 nm and 30 nm respectively. However, metal layer thickness does not cause any significant variation in sensitivity, but as it increases to 50 nm, minimum reflectivity and full width half maximum (FWHM) decreases to the lowest. In case of narrow groove grating structure, broad range of wavelengths can generate SPR and the sensitivity is highest (900nm/RIU) for a configuration of 10 nm groove width and 70 nm groove height at a resonance wavelength of 1411 nm.

preprint2020arXiv

Towards Understanding the Effect of Leak in Spiking Neural Networks

Spiking Neural Networks (SNNs) are being explored to emulate the astounding capabilities of human brain that can learn and compute functions robustly and efficiently with noisy spiking activities. A variety of spiking neuron models have been proposed to resemble biological neuronal functionalities. With varying levels of bio-fidelity, these models often contain a leak path in their internal states, called membrane potentials. While the leaky models have been argued as more bioplausible, a comparative analysis between models with and without leak from a purely computational point of view demands attention. In this paper, we investigate the questions regarding the justification of leak and the pros and cons of using leaky behavior. Our experimental results reveal that leaky neuron model provides improved robustness and better generalization compared to models with no leak. However, leak decreases the sparsity of computation contrary to the common notion. Through a frequency domain analysis, we demonstrate the effect of leak in eliminating the high-frequency components from the input, thus enabling SNNs to be more robust against noisy spike-inputs.

preprint2020arXiv

Unsupervised Abnormality Detection Using Heterogeneous Autonomous Systems

Anomaly detection (AD) in a surveillance scenario is an emerging and challenging field of research. For autonomous vehicles like drones or cars, it is immensely important to distinguish between normal and abnormal states in real-time. Additionally, we also need to detect any device malfunction. But the nature and degree of abnormality may vary depending upon the actual environment and adversary. As a result, it is impractical to model all cases a-priori and use supervised methods to classify. Also, an autonomous vehicle provides various data types like images and other analog or digital sensor data, all of which can be useful in anomaly detection if leveraged fruitfully. To that effect, in this paper, a heterogeneous system is proposed which estimates the degree of abnormality of an unmanned surveillance drone, analyzing real-time image and IMU (Inertial Measurement Unit) sensor data in an unsupervised manner. Here, we have demonstrated a Convolutional Neural Network (CNN) architecture, named AngleNet to estimate the angle between a normal image and another image under consideration, which provides us with a measure of anomaly of the device. Moreover, the IMU data are used in autoencoder to predict abnormality. Finally, the results from these two algorithms are ensembled to estimate the final degree of abnormality. The proposed method performs satisfactorily on the IEEE SP Cup-2020 dataset with an accuracy of 97.3%. Additionally, we have also tested this approach on an in-house dataset to validate its robustness.

preprint2019arXiv

Numerical Analysis of Sensitivity Enhancement of Surface Plasmon Resonance Biosensors Using a Mirrored Bilayer Structure

A mirrored bilayer structure incorporating layers of Graphene and MoS2 is proposed here for Surface Plasmon Resonance (SPR) biosensing and its performance is evaluated numerically. Starting from the basic configuration, the structure with graphene and MoS2 layers is gradually developed for enhanced performance. Reflectance is the main considered parameter for performance analysis. A theoretical framework based on Fresnel's equations is presented and by measuring reflectance versus angle of incidence, sensitivity is calculated from the displacement of SPR angle using finite-difference time-domain (FDTD) technique. Our numerical analysis shows that using the proposed approach, about 4.2 times enhanced sensitivity can be achieved compared to the basic Kretschmann configuration. Notably, the structure provides an enhancement for both angular and wavelength interrogations. Furthermore, simulations have been repeated for various ligate-ligand pairs and consistent enhancement has been observed which proves the robustness of the structure. So, the proposed sensor architecture clearly provides pronounced improvement in sensitivity which can be significant in various practical applications.

preprint2016arXiv

The 10% Gd and Ti co-doped BiFeO$_3$: A promising multiferroic material

In this investigation, undoped BiFeO$_3$, Gd doped Bi$_{0.9}$Gd$_{0.1}$FeO$_3$, and Gd-Ti co-doped Bi$_{0.9}$Gd$_{0.1}$Fe$_{1-x}$Ti$_x$O$_3$ (x = 0.10, 0.20) materials were synthesized to report their multiferroic properties. The structural analysis and phase identification of these multiferroic ceramics were performed using Rietveld refinement. The Rietveld analysis has confirmed the high phase purity of the 10% Gd-Ti co-doped Bi$_{0.9}$Gd$_{0.1}$Fe$_{0.9}$Ti$_{0.1}$O$_3$ sample compared to that of other compositions under investigation. The major phase of this particular composition is of rhombohedral \textit{R3c} type structure (wt% $>99\%$) with negligible amount of impurity phases. In terms of characterization, we address magnetic properties of this co-doped ceramic system by applying substantially higher magnetic fields than that applied in previously reported investigations. The dependence of temperature and maximum applied magnetic fields on their magnetization behavior have also been investigated. Additionally, the leakage current density has been measured to explore its effect on the ferroelectric properties of this multiferroic system. The outcome of this investigation suggests that the substitution of 10% Gd and Ti in place of Bi and Fe, respectively, in BiFeO$_3$ significantly enhances its multiferroic properties. The improved properties of this specific composition is associated with homogeneous reduced grain size, significant suppression of impurity phases and reduction in leakage current density which is further asserted by polarization vs. electric field hysteresis loop measurements.