Researcher profile

S. P. Yakimenko

S. P. Yakimenko contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
14works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

14 published item(s)

preprint2015arXiv

High-resolution ion pulse ionization chamber with air filling for the Rn-222 decays detection

The construction and characteristics of the cylindrical ion pulse ionization chamber (CIPIC) with a working volume of 3.2 L are described. The chamber is intended to register alpha-particles from the $^{222}$Rn and its daughter's decays in the filled air sample. The detector is less sensitive to electromagnetic pick-ups and mechanical noises. The digital pulse processing method is proposed to improve the energy resolution of the ion pulse ionization chamber. An energy resolution of 1.6% has been achieved for the 5.49 MeV alpha-line. The dependence of the energy resolution on high voltage and working media pressure has been investigated and the results are presented.

preprint2015arXiv

New limit on the mass of 9.4-keV solar axions emitted in an M1 transition in $^{83}$Kr nuclei

A search for resonant absorption of the solar axion by $^{83}\rm{Kr}$ nuclei was performed using the proportional counter installed inside the low-background setup at the Baksan Neutrino Observatory. The obtained model independent upper limit on the combination of isoscalar and isovector axion-nucleon couplings $|g_3-g_0|\leq 1.69\times 10^{-6}$ allowed us to set the new upper limit on the hadronic axion mass of $m_{A}\leq 130$ eV (95\% C.L.) with the generally accepted values $S$=0.5 and $z$=0.56.

preprint2015arXiv

Technical Design Report for the AMoRE $0νββ$ Decay Search Experiment

The AMoRE (Advanced Mo-based Rare process Experiment) project is a series of experiments that use advanced cryogenic techniques to search for the neutrinoless double-beta decay of \mohundred. The work is being carried out by an international collaboration of researchers from eight countries. These searches involve high precision measurements of radiation-induced temperature changes and scintillation light produced in ultra-pure \Mo[100]-enriched and \Ca[48]-depleted calcium molybdate ($\mathrm{^{48depl}Ca^{100}MoO_4}$) crystals that are located in a deep underground laboratory in Korea. The \mohundred nuclide was chosen for this \zeronubb decay search because of its high $Q$-value and favorable nuclear matrix element. Tests have demonstrated that \camo crystals produce the brightest scintillation light among all of the molybdate crystals, both at room and at cryogenic temperatures. $\mathrm{^{48depl}Ca^{100}MoO_4}$ crystals are being operated at milli-Kelvin temperatures and read out via specially developed metallic-magnetic-calorimeter (MMC) temperature sensors that have excellent energy resolution and relatively fast response times. The excellent energy resolution provides good discrimination of signal from backgrounds, and the fast response time is important for minimizing the irreducible background caused by random coincidence of two-neutrino double-beta decay events of \mohundred nuclei. Comparisons of the scintillating-light and phonon yields and pulse shape discrimination of the phonon signals will be used to provide redundant rejection of alpha-ray-induced backgrounds. An effective Majorana neutrino mass sensitivity that reaches the expected range of the inverted neutrino mass hierarchy, i.e., 20-50 meV, could be achieved with a 200~kg array of $\mathrm{^{48depl}Ca^{100}MoO_4}$ crystals operating for three years.

preprint2015arXiv

The origin of the background radioactive isotope Xe-127 in the sample of Xe enriched in Xe-124

The results of investigation of Xe-127 radioactive isotope production in the xenon sample enriched in Xe-124, Xe-126, Xe-128 are presented. The isotope is supposed to be the source of the background events in the low-background experiment on search for 2K-capture of Xe-124. In this work we consider two channels of Xe-127 production: the neutron knock-out from Xe-128 nucleus by cosmogenic muons and the neutron capture by Xe-126 nucleus. For the first channel the upper limit of the cross section of Xe-127 production was found to be sigma >= 0.007 barn at 95\% C.L. For the second channel the value obtained for the cross section was found to be equal to sigma =(2.74+-0.4) barn, which coincides well, within the statistical error, with reference value.

preprint2015arXiv

The study of the thermal neutron flux in the deep underground laboratory DULB-4900

We report on the study of thermal neutron flux using monitors based on mixture of ZnS(Ag) and LiF enriched with a lithium-6 isotope at the deep underground laboratory DULB-4900 at the Baksan Neutrino Observatory. An annual modulation of thermal neutron flux in DULB-4900 is observed. Experimental evidences were obtained of correlation between the long-term thermal neutron flux variations and the absolute humidity of the air in laboratory. The amplitude of the modulation exceed 5\% of total neutron flux.

preprint2014arXiv

First result of the experimental search for the 2K-capture of Xe-124 with the copper proportional counter

First result of experiment for searching of 2K-capture of Xe-124 with the large-volume copper proportional counter is given. The 12 litre sample with 63.3% (44 g) of Xe-124 was used in measurements. The limit on the half-life of Xe-124 with regard to 2K(2ν)-capture for the ground state of Te-124 has been found: T_{1/2} > 4.67x10^{20} y (90% C.L.). A sample with volume 52 L comprising of Xe-124 (10.6 L - 58.6 g) and Xe-126 (14.1 L - 79.3 g) will used at the next step of the experiment to increase a sensitivity of 2K-caption of Xe-124 registration. In this case sensitivity to the investigated process will be at the level of S=1.46 x 10^{21} y (90% C.L.) for 1 year measurement.

preprint2014arXiv

First result of the experimental search for the 9.4 keV solar axion reactions with Kr-83 in the copper proportional counter

The experimental search for solar hadronic axions is started at the Baksan Neutrino Observatory of the Institute for Nuclear Researches Russian Academy of Science. It is assumed that axions are created in the Sun during M1-transition between the first thermally excited level at 9.4 keV and the ground state in Kr-83. The experiment is based on axion detection via resonant absorption process by the same nucleus in the detector. The big copper proportional counter filled with krypton is used to detect signals from axions. The experimental setup is situated in the deep underground low background laboratory. No evidence of axion detection were found after the 26.5 days data collection. Resulting new upper limit on axion mass is m_{A} < 130 eV at 95% C.L.

preprint2012arXiv

Working characteristics of the New Low-Background Laboratory (DULB-4900, Baksan Neutrino Observatory)

A concise technical characteristic of a new low-background laboratory DULB-4900 of the BNO INR RAS is presented. The technique and the results of background measurements in the Hall, ordinary box and low-background box are presented. Rn-222 contamination in the laboratory air has been measured by direct detection of gamma-radiation of its daughter Bi-214 distributed over the volume of the low-background box. The results of the data analysis are presented.

preprint2011arXiv

Experimental test of the time stability of the half-life of alpha-decay Po-214 nuclei

A method and results of an experimental test of the time stability of the half-life of alpha-decay Po-214 nuclei are presented. Two underground installations aimed at monitoring the time stability have been constructed. Time of measurement exceeds 1038 days for one set up and 562 days for the other. It was found that amplitude of possible annual variation of Po-214 half-life does not exceed 0.2% of the mean value. The limit on the deviation of the decay curve from exponent at 0.034\times T_{1/2}<t< 0.1\times T_{1/2} range has been found.

preprint2011arXiv

Results of a search for 2β-decay of Xe-136 with high pressure copper proportional counters in Baksan Neutrino Observatory INR RAS

Search for ββ-decay of Xe-136 with two high pressure proportional counters is carried out in Baksan Neutrino Observatory. The experiment is based on comparision of spectra measured with natural and enriched xenon. The measured halfe life is equal to T_{1/2}=5.5^{+4.6}_{-1.7} \cdot 10^{21} yr (67% C.L.) for ββ2ν-decay mode. No evidence has been found for neutrinoless ββ-decay. The decay half life limit based on data measured during 17280 h is T_{1/2}(ββ0ν)\geq 4.9 \cdot 10^{23} yr (90% C.L.).

preprint2011arXiv

Search for 2K(2ν)-capture of Kr-78

Results of a search for Kr-78 double K-capture at the second stage of the experiment with high-pressure copper proportional counters are presented. The method is based on comparison of spectra measured with natural and enriched krypton. The total exposure of the low background measurements is for Kr-78 152 g*yr and for Kr-nat 106 g*yr. An excess of events was observed in the analysis of Kr-78 selected data collected during 2008-2010 years. This excess could correspond to a double K-capture of Kr-78 with the half-life of T_{1/2}(2K,2ν+ 0ν)=[1.4^{+2.2}_{-0.7}]\cdot 10^{22}$ yr (90% C.L.)

preprint2010arXiv

Pulse Shape Analysis and Identification of Multipoint Events in a Large-Volume Proportional Counter in an Experimental Search for 2K Capture Kr-78

A pulse shape analysis algorithm and a method for suppressing the noise component of signals from a large copper proportional counter in the experiment aimed at searching for 2K capture of Kr-78 are described. These signals correspond to a compound event with different numbers of charge clusters due to from primary ionization is formed by these signals. A technique for separating single- and multipoint events and determining the charge in individual clusters is presented. Using the Daubechies wavelets in multiresolutional signal analysis, it is possible to increase the sensitivity and the resolution in extraction of multipoint events in the detector by a factor of 3-4.