Researcher profile

V. V. Kuzminov

V. V. Kuzminov contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
13works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

13 published item(s)

preprint2022arXiv

$^{222}$Rn content variations at ground and underground conditions

The activity of $^{222}$Rn and its daughter isotopes was measured in the air of several underground laboratories of the Baksan Neutrino Observatory at various distances from the entrance. The measurements were carried out with the help of the cylindrical ionionization air chamber. We found that the radon content in the ventilated airflow within the measurement accuracy does not depend on the distance travelled along the adit. In addition, we observed that the radon content increases abruptly in those locations where underground gases and water are released. As a result, we review various mechanisms of air enrichment with radon. We also outline our research methodology and present the results of our measurements of radon release from the rocky walls of the underground laboratory. Finally, we present the results of the measurements of the radon content of various ground and underground water sources.

preprint2022arXiv

A Search for Electron Neutrino Transitions to Sterile States in the BEST Experiment

The Baksan Experiment on Sterile Transitions (BEST) probes the gallium anomaly and its possible connections to oscillations between active and sterile neutrinos. Based on the Gallium-Germanium Neutrino Telescope (GGNT) technology of the SAGE experiment, BEST employs two zones of liquid Ga target to explore neutrino oscillations on the meter scale. Oscillations on this short scale could produce deficits in the $^{71}$Ge production rates within the two zones, as well as a possible rate difference between the zones. From July 5th to October 13th 2019, the two-zone target was exposed to a primarily monoenergetic, 3.4-MCi $^{51}$Cr neutrino source 10 times for a total of 20 independent $^{71}$Ge extractions from the two Ga targets. The $^{71}$Ge production rates from the neutrino source were measured from July 2019 to March 2020. At the end of these measurements, the counters were filled with $^{71}$Ge doped gas and calibrated during November 2020. In this paper, results from the BEST sterile neutrino oscillation experiment are presented in details. The ratio of the measured $^{71}$Ge production rates to the predicted rates for the inner and the outer target volumes are calculated from the known neutrino capture cross section. Comparable deficits in the measured ratios relative to predicted values are found for both zones, with the $4 σ$ deviations from unity consistent with the previously reported gallium anomaly. If interpreted in the context of neutrino oscillations, the deficits give best fit oscillation parameters of $Δm^2=3.3^{+\infty}_{-2.3}$ eV$^2$ and sin$^2 2θ=0.42^{+0.15}_{-0.17}$, consistent with $ν_e \rightarrow ν_s$ oscillations governed by a surprisingly large mixing angle.

preprint2022arXiv

Characteristics of a matrix proportional counter with circular anodes

The construction of a butt-end multicell matrix proportional counter (MMPC) is presented in the work. Each cell is a butt-end proportional counter with a 5 mm cathode diameter and 0.8 mm circular anode diameter. In the example of the $3\times3$ matrix, it is shown that the gas multiplication of the central cell depends on the potentials at the anodes of the peripheral cells, the drift electrode, the forming rings, and the surrounding metal parts of the structure. The amplitude characteristics were measured when the MMPC was filled with mixtures of 96.3\% Ar + 3.7\% Xe and 90\% Ar + 10\% CH$_4$ at pressures of 620 Torr and 62 Torr. The calibration was carried out with $α$-particles and $γ$-quanta from a $^{238}$Pu source. For photons with energies of 7.5 keV, a resolution of 26\% was obtained. It is shown that, based on MMPC, it is possible to fabricate recording surfaces of arbitrary configuration.

preprint2022arXiv

Pulse shape analysis in GERDA Phase II

The GERmanium Detector Array (GERDA) collaboration searched for neutrinoless double-$β$ decay in $^{76}$Ge using isotopically enriched high purity germanium detectors at the Laboratori Nazionali del Gran Sasso of INFN. After Phase I (2011-2013), the experiment benefited from several upgrades, including an additional active veto based on LAr instrumentation and a significant increase of mass by point-contact germanium detectors that improved the half-life sensitivity of Phase II (2015-2019) by an order of magnitude. At the core of the background mitigation strategy, the analysis of the time profile of individual pulses provides a powerful topological discrimination of signal-like and background-like events. Data from regular $^{228}$Th calibrations and physics data were both considered in the evaluation of the pulse shape discrimination performance. In this work, we describe the various methods applied to the data collected in GERDA Phase II corresponding to an exposure of 103.7 kg$\cdot$yr. These methods suppress the background by a factor of about 5 in the region of interest around Q$_{ββ}$ = 2039 keV, while preserving (81$\pm$3)% of the signal. In addition, an exhaustive list of parameters is provided which were used in the final data analysis.

preprint2022arXiv

Results from the Baksan Experiment on Sterile Transitions (BEST)

The Baksan Experiment on Sterile Transitions (BEST) was designed to investigate the deficit of electron neutrinos, $ν_{e}$, observed in previous gallium-based radiochemical measurements with high-intensity neutrino sources, commonly referred to as the \textit{gallium anomaly}, which could be interpreted as evidence for oscillations between $ν_e$ and sterile neutrino ($ν_s$) states. A 3.414-MCi \nuc{51}{Cr} $ν_e$ source was placed at the center of two nested Ga volumes and measurements were made of the production of \nuc{71}{Ge} through the charged current reaction, \nuc{71}{Ga}($ν_e$,e$^-$)\nuc{71}{Ge}, at two average distances. The measured production rates for the inner and the outer targets respectively are ($54.9^{+2.5}_{-2.4}(\mbox{stat})\pm1.4 (\mbox{syst})$) and ($55.6^{+2.7}_{-2.6}(\mbox{stat})\pm1.4 (\mbox{syst})$) atoms of \nuc{71}{Ge}/d. The ratio ($R$) of the measured rate of \nuc{71}{Ge} production at each distance to the expected rate from the known cross section and experimental efficiencies are $R_{in}=0.79\pm0.05$ and $R_{out}= 0.77\pm0.05$. The ratio of the outer to the inner result is 0.97$\pm$0.07, which is consistent with unity within uncertainty. The rates at each distance were found to be similar, but 20-24\% lower than expected, thus reaffirming the anomaly. These results are consistent with $ν_e \rightarrow ν_s$ oscillations with a relatively large $Δm^2$ ($>$0.5 eV$^2$) and mixing sin$^2 2θ$ ($\approx$0.4).

preprint2021arXiv

Calibration of the GERDA experiment

The GERmanium Detector Array (GERDA) collaboration searched for neutrinoless double-$β$ decay in $^{76}$Ge with an array of about 40 high-purity isotopically-enriched germanium detectors. The experimental signature of the decay is a monoenergetic signal at Q$_{ββ}$ = 2039.061(7)keV in the measured summed energy spectrum of the two emitted electrons. Both the energy reconstruction and resolution of the germanium detectors are crucial to separate a potential signal from various backgrounds, such as neutrino-accompanied double-$β$ decays allowed by the Standard Model. The energy resolution and stability were determined and monitored as a function of time using data from regular $^{228}$Th calibrations. In this work, we describe the calibration process and associated data analysis of the full GERDA dataset, tailored to preserve the excellent resolution of the individual germanium detectors when combining data over several years.

preprint2021arXiv

Recent advancements of the experiment to search for $2K$-capture in $^{124}$Xe using a Large Low-background Proportional Counter

A new method for correcting the charge signal from the large proportional counter is proposed. The correction method makes it possible to take into account the loss of primary ionization electrons in the presence of weakly increasing micro impurities of electronegative gases during long-term measurements. It allows increasing the efficiency of the selection of useful events and thereby increasing the sensitivity to $2\nu2K$-decay in $^{124}$Xe at the level of $2\times10^{22}$ from over six years of measurements using a large proportional counter. Analysis of the calibration data, taking into account the new method for correcting the energy release in the detector, made it possible to register events from double $K$ photoionization by a single photon.

preprint2020arXiv

Annual variations of the $^{214}$Po, $^{213}$Po and $^{212}$Po half-life values

Results of a comparative analysis of the $^{214}$Po ($T_{1/2}= 163.47\pm0.03$ $μ$s), $^{213}$Po ($T_{1/2}=3.705 \pm 0.001$ $μ$s) and $^{212}$Po ($T_{1/2}=294.09\pm0.07$ ns) half-life annular variation parameters are presented. It is shown that two independent sequential sets of the $^{214}$Po $τ$-values $(τ\equiv T_{1/2})$ obtained in the spaced laboratories can be described by sinusoidal functions. The sinusoid curve with amplitude $A=(5.0 \pm1.5) \cdot 10^{-4}$, period $ω=(365\pm 8)$ days, and phase $ϕ=(170 \pm 7)$ days approximates the set of $^{214}$Po $τ$ values obtained at BNO INR RAS during the $\sim$973 days starting on January 4, 2012. The function approximates a set of $τ$-values with a time duration of $\sim1460$ days obtained at the KhNU has an amplitude $A=(4.9\pm1.8)\cdot10^{-4}$, a period $ω= (377\pm13)$ days and a phase $ϕ=(77\pm10)$ days. The $^{213}$Po $τ$-value set with a time duration of $\sim1700$ days can be described by a sinusoidal function with an amplitude $A=(3.9\pm1.2)\cdot10^{-4}$, a period $ω= (370\pm13)$ days and a phase $ϕ=(130\pm9)$ days. The $^{212}$Po $τ$-value set with a time duration of $\sim670$ days can be described by a sinusoidal function with an amplitude $A=(7.5\pm1.6)\cdot10^{-4}$, a period $ω= (375\pm13)$ days and a phase $ϕ=(40\pm10)$ days.

preprint2020arXiv

Final Results of GERDA on the Search for Neutrinoless Double-$β$ Decay

The GERmanium Detector Array (GERDA) experiment searched for the lepton-number-violating neutrinoless double-$β$ ($0νββ$) decay of $^{76}$Ge, whose discovery would have far-reaching implications in cosmology and particle physics. By operating bare germanium diodes, enriched in $^{76}$Ge, in an active liquid argon shield, GERDA achieved an unprecedently low background index of $5.2\times10^{-4}$ counts/(keV$\cdot$kg$\cdot$yr) in the signal region and met the design goal to collect an exposure of 100 kg$\cdot$yr in a background-free regime. When combined with the result of Phase I, no signal is observed after 127.2 kg$\cdot$yr of total exposure. A limit on the half-life of $0νββ$ decay in $^{76}$Ge is set at $T_{1/2}>1.8\times10^{26}$ yr at 90% C.L., which coincides with the sensitivity assuming no signal.

preprint2020arXiv

The first search for bosonic super-WIMPs with masses up to 1 MeV/c$^2$ with GERDA

We present the first search for bosonic super-WIMPs as keV-scale dark matter candidates performed with the GERDA experiment. GERDA is a neutrinoless double-beta decay experiment which operates high-purity germanium detectors enriched in $^{76}$Ge in an ultra-low background environment at the Laboratori Nazionali del Gran Sasso (LNGS) of INFN in Italy. Searches were performed for pseudoscalar and vector particles in the mass region from 60 keV/c$^2$ to 1 MeV/c$^2$. No evidence for a dark matter signal was observed, and the most stringent constraints on the couplings of super-WIMPs with masses above 120 keV/c$^2$ have been set. As an example, at a mass of 150 keV/c$^2$ the most stringent direct limits on the dimensionless couplings of axion-like particles and dark photons to electrons of $g_{ae} < 3 \cdot 10^{-12}$ and ${α&#39;}/α < 6.5 \cdot 10^{-24}$ at 90% credible interval, respectively, were obtained.

preprint2019arXiv

Modeling of a MeV-scale Particle Detector Based on Organic Liquid Scintillator

The detectors based on the liquid scintillator (LS) monitored by an array of photo-multiplier tubes (PMT) are often used in low energy experiments such as neutrino oscillation studies and search for dark matter. Detectors of this kind operate in an energy range spanning from hundreds of keV to a few GeV providing a few percent resolution at energies above 1 MeV and allowing to observe fine spectral features. This article gives a brief overview of relevant physical processes and introduces a new universal simulation tool LSMC (Liquid Scintillator Monte Carlo) for simulation of LS-based detectors equipped with PMT arrays. This tool is based on the Geant4 framework and provides supplementing functionality for ease of configuration and comprehensive output. The usage of LSMC is illustrated by modeling and optimization of a compact detector prototype currently being built at Baksan Neutrino Observatory.

preprint2018arXiv

The background simulation of experiment for searching of $2\nu2K$ capture in Xe-124

We describe the Monte Carlo (MC) simulation package of the `2K-CAPTURE&#39; setup and discuss the agreement of its output with data. The `2K-CAPTURE&#39; MC simulates the energy loss of particles in detector and components of the passive shield and generates the resulting response in working volume large proportional counter (LPC). The simulation accounts for absorption, reemission, and scattering of both photons and neutrons and tracks them until they either are absorbed. The algorithm proceeds with a detailed simulation of the electronics chain. The MC is tuned using data collected with radioactive calibration source deployed in the internal channel of the installation. The simulation reproduces the energy response of the detector corresponding to distribution of the generated pointwise clusters of a charge of primary ionization in LPC.

preprint2017arXiv

Searching for neutrinoless double beta decay with GERDA

The GERmanium Detector Array (GERDA) experiment located at the INFN Gran Sasso Laboratory (Italy), is looking for the neutrinoless double beta decay of Ge76, by using high-purity germanium detectors made from isotopically enriched material. The combination of the novel experimental design, the careful material selection for radio-purity and the active/passive shielding techniques result in a very low residual background at the Q-value of the decay, about 1e-3 counts/(keV kg yr). This makes GERDA the first experiment in the field to be background-free for the complete design exposure of 100 kg yr. A search for neutrinoless double beta decay was performed with a total exposure of 47.7 kg yr: 23.2 kg yr come from the second phase (Phase II) of the experiment, in which the background is reduced by about a factor of ten with respect to the previous phase. The analysis presented in this paper includes 12.4 kg yr of new Phase II data. No evidence for a possible signal is found: the lower limit for the half-life of Ge76 is 8.0e25 yr at 90% CL. The experimental median sensitivity is 5.8e25 yr. The experiment is currently taking data. As it is running in a background-free regime, its sensitivity grows linearly with exposure and it is expected to surpass 1e26 yr within 2018.