Source author record

S. S. Ratkevich

S. S. Ratkevich appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

24works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

24 published item(s)

preprint2022arXiv

$^{222}$Rn content variations at ground and underground conditions

The activity of $^{222}$Rn and its daughter isotopes was measured in the air of several underground laboratories of the Baksan Neutrino Observatory at various distances from the entrance. The measurements were carried out with the help of the cylindrical ionionization air chamber. We found that the radon content in the ventilated airflow within the measurement accuracy does not depend on the distance travelled along the adit. In addition, we observed that the radon content increases abruptly in those locations where underground gases and water are released. As a result, we review various mechanisms of air enrichment with radon. We also outline our research methodology and present the results of our measurements of radon release from the rocky walls of the underground laboratory. Finally, we present the results of the measurements of the radon content of various ground and underground water sources.

preprint2021arXiv

Recent advancements of the experiment to search for $2K$-capture in $^{124}$Xe using a Large Low-background Proportional Counter

A new method for correcting the charge signal from the large proportional counter is proposed. The correction method makes it possible to take into account the loss of primary ionization electrons in the presence of weakly increasing micro impurities of electronegative gases during long-term measurements. It allows increasing the efficiency of the selection of useful events and thereby increasing the sensitivity to $2\nu2K$-decay in $^{124}$Xe at the level of $2\times10^{22}$ from over six years of measurements using a large proportional counter. Analysis of the calibration data, taking into account the new method for correcting the energy release in the detector, made it possible to register events from double $K$ photoionization by a single photon.

preprint2020arXiv

Annual variations of the $^{214}$Po, $^{213}$Po and $^{212}$Po half-life values

Results of a comparative analysis of the $^{214}$Po ($T_{1/2}= 163.47\pm0.03$ $μ$s), $^{213}$Po ($T_{1/2}=3.705 \pm 0.001$ $μ$s) and $^{212}$Po ($T_{1/2}=294.09\pm0.07$ ns) half-life annular variation parameters are presented. It is shown that two independent sequential sets of the $^{214}$Po $τ$-values $(τ\equiv T_{1/2})$ obtained in the spaced laboratories can be described by sinusoidal functions. The sinusoid curve with amplitude $A=(5.0 \pm1.5) \cdot 10^{-4}$, period $ω=(365\pm 8)$ days, and phase $ϕ=(170 \pm 7)$ days approximates the set of $^{214}$Po $τ$ values obtained at BNO INR RAS during the $\sim$973 days starting on January 4, 2012. The function approximates a set of $τ$-values with a time duration of $\sim1460$ days obtained at the KhNU has an amplitude $A=(4.9\pm1.8)\cdot10^{-4}$, a period $ω= (377\pm13)$ days and a phase $ϕ=(77\pm10)$ days. The $^{213}$Po $τ$-value set with a time duration of $\sim1700$ days can be described by a sinusoidal function with an amplitude $A=(3.9\pm1.2)\cdot10^{-4}$, a period $ω= (370\pm13)$ days and a phase $ϕ=(130\pm9)$ days. The $^{212}$Po $τ$-value set with a time duration of $\sim670$ days can be described by a sinusoidal function with an amplitude $A=(7.5\pm1.6)\cdot10^{-4}$, a period $ω= (375\pm13)$ days and a phase $ϕ=(40\pm10)$ days.

preprint2018arXiv

The background simulation of experiment for searching of $2\nu2K$ capture in Xe-124

We describe the Monte Carlo (MC) simulation package of the `2K-CAPTURE' setup and discuss the agreement of its output with data. The `2K-CAPTURE' MC simulates the energy loss of particles in detector and components of the passive shield and generates the resulting response in working volume large proportional counter (LPC). The simulation accounts for absorption, reemission, and scattering of both photons and neutrons and tracks them until they either are absorbed. The algorithm proceeds with a detailed simulation of the electronics chain. The MC is tuned using data collected with radioactive calibration source deployed in the internal channel of the installation. The simulation reproduces the energy response of the detector corresponding to distribution of the generated pointwise clusters of a charge of primary ionization in LPC.

preprint2015arXiv

Characteristics of a thermal neutrons scintillation detector with the [ZnS(Ag)+$^6$LiF] at different conditions of measurements

A construction of a thermal neutron testing detector with a thin [ZnS(Ag)+$^6$LiF] scintillator is described. Results of an investigation of sources of the detector pulse origin and the pulse features in a ground and underground conditions are presented. Measurements of the scintillator own background, registration efficiency and a neutron flux at different objects of the BNO INR RAS were performed. The results are compared with the ones measured by the $^3$He proportional counter.

preprint2015arXiv

High-resolution ion pulse ionization chamber with air filling for the Rn-222 decays detection

The construction and characteristics of the cylindrical ion pulse ionization chamber (CIPIC) with a working volume of 3.2 L are described. The chamber is intended to register alpha-particles from the $^{222}$Rn and its daughter's decays in the filled air sample. The detector is less sensitive to electromagnetic pick-ups and mechanical noises. The digital pulse processing method is proposed to improve the energy resolution of the ion pulse ionization chamber. An energy resolution of 1.6% has been achieved for the 5.49 MeV alpha-line. The dependence of the energy resolution on high voltage and working media pressure has been investigated and the results are presented.

preprint2015arXiv

New limit on the mass of 9.4-keV solar axions emitted in an M1 transition in $^{83}$Kr nuclei

A search for resonant absorption of the solar axion by $^{83}\rm{Kr}$ nuclei was performed using the proportional counter installed inside the low-background setup at the Baksan Neutrino Observatory. The obtained model independent upper limit on the combination of isoscalar and isovector axion-nucleon couplings $|g_3-g_0|\leq 1.69\times 10^{-6}$ allowed us to set the new upper limit on the hadronic axion mass of $m_{A}\leq 130$ eV (95\% C.L.) with the generally accepted values $S$=0.5 and $z$=0.56.

preprint2015arXiv

Results of a search for daily and annual variations of the Po-214 half-life at the two year observation period

The brief description of installation TAU-2 intended for long-term monitoring of the half-life value $τ$ ($τ_{1/2}$) of the $^{214}$Po is presented. The methods of measurement and processing of collected data are reported. The results of analysis of time series values $τ$ with different time step are presented. Total of measurement time was equal to 590 days. Averaged value of the $^{214}$Po half-life was obtained $τ=163.46\pm0.04$ $μ$s. The annual variation with an amplitude $A=(8.9\pm2.3)\cdot10^{-4}$, solar-daily variation with an amplitude $A_{So}=(7.5\pm1.2)\cdot10^{-4}$, lunar-daily variation with an amplitude $A_L=(6.9\pm2.0)\cdot10^{-4}$ and sidereal-daily variation with an amplitude $A_S=(7.2\pm1.2)\cdot10^{-4}$ were found in a series of $τ$ values. The maximal values of amplitude are observed at the moments when the projections of the installation Earth location velocity vectors toward the source of possible variation achieve its maximal magnitudes.

preprint2015arXiv

Results of measurements of an environment neutron background at BNO INR RAS objects with the helium proportional counter

A method of measurements of the environmental neutron background at the Baksan Neutrino Observatory of the INR RAS are described. Measurements were done by using of a proportional counter filled with mixture of Ar(2 at)+$^3$He(4 at). The results obtained at the surface and the underground laboratory of the BNO INR RAS are presented. It is shown that a neutron background in the underground laboratory at the 4900 m w.e. depth is decreased by $\sim 260$ times without any special shield in a comparison with the Earth surface. A neutron flux density in the 5-1323.5~cm air height region is constant within the determination error and equal to $(7.1\pm0.1_{\rm{stat}}\pm0.3_{\rm{syst}})\times10^{-3}$ s$^{-1}\cdot$cm$^{-2}$.

preprint2015arXiv

Technical Design Report for the AMoRE $0νββ$ Decay Search Experiment

The AMoRE (Advanced Mo-based Rare process Experiment) project is a series of experiments that use advanced cryogenic techniques to search for the neutrinoless double-beta decay of \mohundred. The work is being carried out by an international collaboration of researchers from eight countries. These searches involve high precision measurements of radiation-induced temperature changes and scintillation light produced in ultra-pure \Mo[100]-enriched and \Ca[48]-depleted calcium molybdate ($\mathrm{^{48depl}Ca^{100}MoO_4}$) crystals that are located in a deep underground laboratory in Korea. The \mohundred nuclide was chosen for this \zeronubb decay search because of its high $Q$-value and favorable nuclear matrix element. Tests have demonstrated that \camo crystals produce the brightest scintillation light among all of the molybdate crystals, both at room and at cryogenic temperatures. $\mathrm{^{48depl}Ca^{100}MoO_4}$ crystals are being operated at milli-Kelvin temperatures and read out via specially developed metallic-magnetic-calorimeter (MMC) temperature sensors that have excellent energy resolution and relatively fast response times. The excellent energy resolution provides good discrimination of signal from backgrounds, and the fast response time is important for minimizing the irreducible background caused by random coincidence of two-neutrino double-beta decay events of \mohundred nuclei. Comparisons of the scintillating-light and phonon yields and pulse shape discrimination of the phonon signals will be used to provide redundant rejection of alpha-ray-induced backgrounds. An effective Majorana neutrino mass sensitivity that reaches the expected range of the inverted neutrino mass hierarchy, i.e., 20-50 meV, could be achieved with a 200~kg array of $\mathrm{^{48depl}Ca^{100}MoO_4}$ crystals operating for three years.

preprint2015arXiv

The origin of the background radioactive isotope Xe-127 in the sample of Xe enriched in Xe-124

The results of investigation of Xe-127 radioactive isotope production in the xenon sample enriched in Xe-124, Xe-126, Xe-128 are presented. The isotope is supposed to be the source of the background events in the low-background experiment on search for 2K-capture of Xe-124. In this work we consider two channels of Xe-127 production: the neutron knock-out from Xe-128 nucleus by cosmogenic muons and the neutron capture by Xe-126 nucleus. For the first channel the upper limit of the cross section of Xe-127 production was found to be sigma >= 0.007 barn at 95\% C.L. For the second channel the value obtained for the cross section was found to be equal to sigma =(2.74+-0.4) barn, which coincides well, within the statistical error, with reference value.

preprint2015arXiv

The study of the thermal neutron flux in the deep underground laboratory DULB-4900

We report on the study of thermal neutron flux using monitors based on mixture of ZnS(Ag) and LiF enriched with a lithium-6 isotope at the deep underground laboratory DULB-4900 at the Baksan Neutrino Observatory. An annual modulation of thermal neutron flux in DULB-4900 is observed. Experimental evidences were obtained of correlation between the long-term thermal neutron flux variations and the absolute humidity of the air in laboratory. The amplitude of the modulation exceed 5\% of total neutron flux.

preprint2014arXiv

First result of the experimental search for the 2K-capture of Xe-124 with the copper proportional counter

First result of experiment for searching of 2K-capture of Xe-124 with the large-volume copper proportional counter is given. The 12 litre sample with 63.3% (44 g) of Xe-124 was used in measurements. The limit on the half-life of Xe-124 with regard to 2K(2ν)-capture for the ground state of Te-124 has been found: T_{1/2} > 4.67x10^{20} y (90% C.L.). A sample with volume 52 L comprising of Xe-124 (10.6 L - 58.6 g) and Xe-126 (14.1 L - 79.3 g) will used at the next step of the experiment to increase a sensitivity of 2K-caption of Xe-124 registration. In this case sensitivity to the investigated process will be at the level of S=1.46 x 10^{21} y (90% C.L.) for 1 year measurement.

preprint2014arXiv

First result of the experimental search for the 9.4 keV solar axion reactions with Kr-83 in the copper proportional counter

The experimental search for solar hadronic axions is started at the Baksan Neutrino Observatory of the Institute for Nuclear Researches Russian Academy of Science. It is assumed that axions are created in the Sun during M1-transition between the first thermally excited level at 9.4 keV and the ground state in Kr-83. The experiment is based on axion detection via resonant absorption process by the same nucleus in the detector. The big copper proportional counter filled with krypton is used to detect signals from axions. The experimental setup is situated in the deep underground low background laboratory. No evidence of axion detection were found after the 26.5 days data collection. Resulting new upper limit on axion mass is m_{A} < 130 eV at 95% C.L.

preprint2014arXiv

Sources of the systematic errors in measurements of Po-214 decay half-life time variations at the Baksan deep underground experiments

The design changes of the Baksan low-background TAU-1 and TAU-2 set-ups allowed to improve a sensitivity of Po-214 half-life (τ) measurements up to the 2.5 x 10^{-4} are described. Different possible sources of systematic errors influencing on the $τ$-value are studed. An annual variation of Po-214 half-life time measurements with an amplitude of A=(6.9 \pm 3) x 10^{-4} and a phase of (ϕ=93 \pm 10) days was found in a sequence of the week-collected τ-values obtained from the TAU-2 data sample with total duration of 480 days. 24 hours' variation of the τ-value measurements with an amplitude of A=(10.0 \pm 2.6) x 10^{-4} and phase of (ϕ=1 \pm 0.5) hours was found in a solar day 1 hour step τ-value sequence formed from the same data sample. It was found that the Po-214 half-life averaged at 480 days is equal to (163.45 \pm 0.04) mks.

preprint2012arXiv

Working characteristics of the New Low-Background Laboratory (DULB-4900, Baksan Neutrino Observatory)

A concise technical characteristic of a new low-background laboratory DULB-4900 of the BNO INR RAS is presented. The technique and the results of background measurements in the Hall, ordinary box and low-background box are presented. Rn-222 contamination in the laboratory air has been measured by direct detection of gamma-radiation of its daughter Bi-214 distributed over the volume of the low-background box. The results of the data analysis are presented.

preprint2011arXiv

Experimental test of the time stability of the half-life of alpha-decay Po-214 nuclei

A method and results of an experimental test of the time stability of the half-life of alpha-decay Po-214 nuclei are presented. Two underground installations aimed at monitoring the time stability have been constructed. Time of measurement exceeds 1038 days for one set up and 562 days for the other. It was found that amplitude of possible annual variation of Po-214 half-life does not exceed 0.2% of the mean value. The limit on the deviation of the decay curve from exponent at 0.034\times T_{1/2}<t< 0.1\times T_{1/2} range has been found.

preprint2011arXiv

Results of a search for 2β-decay of Xe-136 with high pressure copper proportional counters in Baksan Neutrino Observatory INR RAS

Search for ββ-decay of Xe-136 with two high pressure proportional counters is carried out in Baksan Neutrino Observatory. The experiment is based on comparision of spectra measured with natural and enriched xenon. The measured halfe life is equal to T_{1/2}=5.5^{+4.6}_{-1.7} \cdot 10^{21} yr (67% C.L.) for ββ2ν-decay mode. No evidence has been found for neutrinoless ββ-decay. The decay half life limit based on data measured during 17280 h is T_{1/2}(ββ0ν)\geq 4.9 \cdot 10^{23} yr (90% C.L.).

preprint2011arXiv

Search for 2K(2ν)-capture of Kr-78

Results of a search for Kr-78 double K-capture at the second stage of the experiment with high-pressure copper proportional counters are presented. The method is based on comparison of spectra measured with natural and enriched krypton. The total exposure of the low background measurements is for Kr-78 152 g*yr and for Kr-nat 106 g*yr. An excess of events was observed in the analysis of Kr-78 selected data collected during 2008-2010 years. This excess could correspond to a double K-capture of Kr-78 with the half-life of T_{1/2}(2K,2ν+ 0ν)=[1.4^{+2.2}_{-0.7}]\cdot 10^{22}$ yr (90% C.L.)

preprint2010arXiv

Pulse Shape Analysis and Identification of Multipoint Events in a Large-Volume Proportional Counter in an Experimental Search for 2K Capture Kr-78

A pulse shape analysis algorithm and a method for suppressing the noise component of signals from a large copper proportional counter in the experiment aimed at searching for 2K capture of Kr-78 are described. These signals correspond to a compound event with different numbers of charge clusters due to from primary ionization is formed by these signals. A technique for separating single- and multipoint events and determining the charge in individual clusters is presented. Using the Daubechies wavelets in multiresolutional signal analysis, it is possible to increase the sensitivity and the resolution in extraction of multipoint events in the detector by a factor of 3-4.

preprint2010arXiv

Results of wavelet processing of the 2K-capture Kr-78 experiment statistics

Results of a search for Kr-78 double K-capture with the large low-background proportional counter (2005-2008 years) at the Baksan Neutrino Observatory are presented. An experimental method and characteristics of detectors are described. Basic features of the digitized pulses processing using wavelet transform are considered. With due account taken of the analysis of individual noise characteristic it has been shown that the appropriate choice of both wavelet characteristics and sequence of processing algorithms allows one to decrease the background in the energy region of useful events with a unique set of characteristics by ~2000 times. New limit on the half-life of Kr-78 with regard to 2K-capture has been found: T_{1/2} >= 2.4E21 yrs (90% C.L.).

preprint2002arXiv

Characteristics of proportional counter filled with CF$_4$ and Xe additions

In this article the measurement results of proportional counter working characteristics filled with CF$_4$ and Xe ($0\div5$% Xe) additions at different pressures ($0.8\div14.8$ $at$) are presented. We have found that a bit of Xe addition reduces working voltage necessary to get the same gas amplification by two times against pure CF$_4$, it improves as well the resolution of the counter and increases limit gas amplification by more than ten times.