Source author record

S. Mianowski

S. Mianowski appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2021arXiv

POLAR-2: a large scale gamma-ray polarimeter for GRBs

The prompt emission of GRBs has been investigated for more than 50 years but remains poorly understood. Commonly, spectral and temporal profiles of γ-ray emission are analysed. However, they are insufficient for a complete picture on GRB-related physics. The addition of polarization measurements provides invaluable information towards the understanding of these astrophysical sources. In recent years, dedicated polarimeters, such as POLAR and GAP, were built. The former of which observed low levels of polarization as well as a temporal evolution of the polarization angle. It was understood that a larger sample of GRB polarization measurements and time resolved studies are necessary to constrain theoretical models. The POLAR-2 mission aims to address this by increasing the effective area by an order of magnitude compared to POLAR. POLAR-2 is manifested for launch on board the China Space Station in 2024 and will operate for at least 2 years. Insight from POLAR will aid in the improvement of the overall POLAR-2 design. Major improvements (compared to POLAR) will include the replacement of multi-anode PMTs (MAPMTs) with SiPMs, increase in sensitive volume and further technological upgrades. POLAR-2 is projected to measure about 50 GRBs per year with equal or better quality compared to the best seen by POLAR. The instrument design, preliminary results and anticipated scientific potential of this mission will be discussed.

preprint2020arXiv

SiPM proton irradiation for application in cosmic space

This paper presents the results of the proton irradiation of silicon photomulipliers (SiPMs) by mono-energetic 170 MeV protons with fluence up to 4.6$\times$10$^{9}$ particles/cm$^2$. In our work, three types of silicon photodetectors from Hamamatsu with areas 3$\times$3 mm$^2$ and different subpixel sizes of 25$\times$25 $μ$m$^2$, 50$\times$50 $μ$m$^2$, and 75$\times$75 $μ$m$^2$ were used. The changes in the SiPM dark count rate (DCR) spectrum before and after irradiation in temperatures in the range of 20 $^\circ$C to -65 $^\circ$C are presented. The influence of the DCR changes on the energy resolution of the 662 keV gamma line from the $^{137}$Cs for a non-irradiated GAGG:Ce (1$\%$) scintillator is investigated. The time period of usability of the SiPM detector irradiated by protons in cosmic space was estimated.

preprint2014arXiv

Proton spectroscopy of 48Ni, 46Fe, and 44Cr

Results of decay spectroscopy on nuclei in vicinity of the doubly magic 48Ni are presented. The measurements were performed with a Time Projection Chamber with optical readout which records tracks of ions and protons in the gaseous volume. Six decays of 48Ni including four events of two-proton ground-state radioactivity were recorded. An advanced reconstruction procedure yielded the 2p decay energy for 48Ni of Q2p = 1.29(4) MeV. In addition, the energy spectra of \b{eta}-delayed protons emitted in the decays of 44Cr and 46Fe, as well as half-lives and branching ratios were determined. The results were found to be consistent with the previous measurements made with Si detectors. A new proton line in the decay of 44Cr corresponding to the decay energy of 760 keV is reported. The first evidence for the \b{eta}2p decay of 46 Fe, based on one clear event, is shown.

preprint2010arXiv

Radiative electron capture in the first forbidden unique decay of 81Kr

The photon spectrum accompanying the orbital K-electron capture in the first forbidden unique decay of 81Kr was measured. The total radiation intensity for the photon energies larger than 50 keV was found to be 1.47(6) x 10^{-4} per K-capture. Both the shape of the spectrum and its intensity relative to the ordinary, non-radiative capture rate, are compared to theoretical predictions. The best agreement is found for the recently developed model which employs the length gauge for the electromagnetic field.