Source author record

M. Pomorski

M. Pomorski appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

Snowmass 2021 White Paper Instrumentation Frontier 05 -- White Paper 1: MPGDs: Recent advances and current R&D

This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51 collaboration which has become the critical organization for the promotion of MPGDs and all aspects of their production, characterization, simulation, and uses in an expanding array of experimental configurations. For the Snowmass 2021 study, a number of Letters of Interest were received that illustrate ongoing developments and expansion of the use of MPGDs. In this paper, we highlight high precision timing, high rate application, trigger capability expansion of the SRS readout system, and a structure designed for low ion backflow.

preprint2021arXiv

Timing performance of a multi-pad PICOSEC-Micromegas detector prototype

The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a muon beam over four representative pads. We demonstrate that such a device, scalable to a larger area, provides excellent time resolution and detection efficiency. As expected from earlier single-cell device studies, we measure a time resolution of approximately 25 picoseconds for charged particles hitting near the anode pad centers, and up to 30 picoseconds at the pad edges. Here, we study in detail the effect of drift gap thickness non-uniformity on the timing performance and evaluate impact position based corrections to obtain a uniform timing response over the full detector coverage.

preprint2020arXiv

Magnetic moments of short-lived nuclei with part-per-million accuracy: Towards novel applications of $β$-detected NMR in physics, chemistry and biology

We determine for the first time the magnetic dipole moment of a short-lived nucleus with part-per-million (ppm) accuracy. To achieve this two orders of magnitude improvement over previous studies, we implement a number of innovations into our $β$-detected Nuclear Magnetic Resonance ($β$-NMR) setup at ISOLDE/CERN. Using liquid samples as hosts we obtain narrow, sub-kHz linewidth, resonances, while a simultaneous in-situ $^1$H NMR measurement allows us to calibrate and stabilize the magnetic field to ppm precision, thus eliminating the need for additional $β$-NMR reference measurements. Furthermore, we use ab initio calculations of NMR shielding constants to improve the accuracy of the reference magnetic moment, thus removing a large systematic error. We demonstrate the potential of this combined approach with the 1.1 s half-life radioactive nucleus $^{26}$Na, which is relevant for biochemical studies. Our technique can be readily extended to other isotopic chains, providing accurate magnetic moments for many short-lived nuclei. Furthermore, we discuss how our approach can open the path towards a wide range of applications of the ultra-sensitive $β$-NMR in physics, chemistry, and biology.

preprint2015arXiv

\b{eta}-delayed three-proton decay of 31Ar

The beta decay of 31Ar, produced by fragmentation of a 36Ar beam at 880 MeV/nucleon, was investigated. Identified ions of 31Ar were stopped in a gaseous time projection chamber with optical readout allowing to record decay events with emission of protons. In addition to \b{eta}-delayed emission of one and two protons we have clearly observed the beta-delayed three-proton branch. The branching ratio for this channel in 31Ar is found to be 0.07(2)%.

preprint2014arXiv

Proton spectroscopy of 48Ni, 46Fe, and 44Cr

Results of decay spectroscopy on nuclei in vicinity of the doubly magic 48Ni are presented. The measurements were performed with a Time Projection Chamber with optical readout which records tracks of ions and protons in the gaseous volume. Six decays of 48Ni including four events of two-proton ground-state radioactivity were recorded. An advanced reconstruction procedure yielded the 2p decay energy for 48Ni of Q2p = 1.29(4) MeV. In addition, the energy spectra of \b{eta}-delayed protons emitted in the decays of 44Cr and 46Fe, as well as half-lives and branching ratios were determined. The results were found to be consistent with the previous measurements made with Si detectors. A new proton line in the decay of 44Cr corresponding to the decay energy of 760 keV is reported. The first evidence for the \b{eta}2p decay of 46 Fe, based on one clear event, is shown.

preprint2011arXiv

Discovery and Cross-Section Measurement of Neutron-Rich Isotopes in the Element Range from Neodymium to Platinum at the FRS

With a new detector setup and the high-resolution performance of the fragment separator FRS at GSI we discovered 57 new isotopes in the atomic number range of 60$\leq Z \leq 78$: \nuc{159-161}{Nb}, \nuc{160-163}{Pm}, \nuc{163-166}Sm, \nuc{167-168}{Eu}, \nuc{167-171}{Gd}, \nuc{169-171}{Tb}, \nuc{171-174}{Dy}, \nuc{173-176}{Ho}, \nuc{176-178}{Er}, \nuc{178-181}{Tm}, \nuc{183-185}{Yb}, \nuc{187-188}{Lu}, \nuc{191}{Hf}, \nuc{193-194}{Ta}, \nuc{196-197}{W}, \nuc{199-200}{Re}, \nuc{201-203}{Os}, \nuc{204-205}{Ir} and \nuc{206-209}{Pt}. The new isotopes have been unambiguously identified in reactions with a $^{238}$U beam impinging on a Be target at 1 GeV/u. The isotopic production cross-section for the new isotopes have been measured and compared with predictions of different model calculations. In general, the ABRABLA and COFRA models agree better than a factor of two with the new data, whereas the semiempirical EPAX model deviates much more. Projectile fragmentation is the dominant reaction creating the new isotopes, whereas fission contributes significantly only up to about the element holmium.

preprint2010arXiv

Beta-Delayed Proton Emission Branches in 43Cr

The beta+ decay of very neutron deficient 43Cr has been studied by means of an imaging time projection chamber which allowed recording tracks of charged particles. Events of beta-delayed emission of one-, two-, and three protons were clearly identified. The absolute branching ratios for these channels were determined to be 81(4)%, 7.1(4)%, and 0.08(3)%, respectively. The 43Cr is thus established as the second case in which the beta-3p decay occurs. Although the feeding to the proton-bound states in 43V is expected to be negligible, the large branching ratio of 12(4)% for decays without proton emission is found.

preprint2010arXiv

Radiative electron capture in the first forbidden unique decay of 81Kr

The photon spectrum accompanying the orbital K-electron capture in the first forbidden unique decay of 81Kr was measured. The total radiation intensity for the photon energies larger than 50 keV was found to be 1.47(6) x 10^{-4} per K-capture. Both the shape of the spectrum and its intensity relative to the ordinary, non-radiative capture rate, are compared to theoretical predictions. The best agreement is found for the recently developed model which employs the length gauge for the electromagnetic field.

preprint2007arXiv

Diamond thin Film Detectors for Beam Monitoring Devices

Diamonds offer radiation hard sensors, which can be used directly in primary beams. Here we report on the use of a polycrystalline CVD diamond strip sensor as beam monitor of heavy ion beams with up to 2.10^9 lead ions per bunch. The strips allow for a determination of the transverse beam profile to a fraction of the pitch of the strips, while the timing information yields the longitudinal bunch length with a resolution of the order of a few mm.