Abstract

This paper presents the results of the proton irradiation of silicon photomulipliers (SiPMs) by mono-energetic 170 MeV protons with fluence up to 4.6×\times109^{9} particles/cm2^2. In our work, three types of silicon photodetectors from Hamamatsu with areas 3×\times3 mm2^2 and different subpixel sizes of 25×\times25 μμm2^2, 50×\times50 μμm2^2, and 75×\times75 μμm2^2 were used. The changes in the SiPM dark count rate (DCR) spectrum before and after irradiation in temperatures in the range of 20 ∘^\circC to -65 ∘^\circC are presented. The influence of the DCR changes on the energy resolution of the 662 keV gamma line from the 137^{137}Cs for a non-irradiated GAGG:Ce (1%\%) scintillator is investigated. The time period of usability of the SiPM detector irradiated by protons in cosmic space was estimated.

Explore this paper’s authors, topics and related work.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Reviews 0

Write a reviewWrite

No reviews yet.

Discussion 0

Add a commentWrite

No comments yet.