Source author record

S. K. L. Sjue

S. K. L. Sjue appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2019arXiv

Final results for the neutron $β$-asymmetry parameter $A_0$ from the UCNA experiment

The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.

preprint2014arXiv

Radial distribution of charged particles in a magnetic field

The radial spread of charged particles emitted from a point source in a magnetic field is a potential source of systematic error for any experiment where magnetic fields guide charged particles to detectors with finite size. Assuming uniform probability as a function of the phase along the particle's helical trajectory, an analytic solution for the radial probability distribution function follows which applies to experiments in which particles are generated throughout a volume that spans a sufficient length along the axis of a homogeneous magnetic field. This approach leads to the same result as a different derivation given by Dubbers et al. But the constant phase approximation does not strictly apply to finite source volumes or fixed positions, which lead to local maxima in the radial distribution of emitted particles at the plane of the detector. A simple method is given to calculate such distributions, then the effect is demonstrated with data from a $^{207}$Bi electron-conversion source in the superconducting solenoid magnet spectrometer of the Ultracold Neutron facility at the Los Alamos Neutron Science Center. Potential future applications of this effect are discussed.

preprint2013arXiv

Storage of ultracold neutrons in the UCN$τ$ magneto-gravitational trap

The UCN$τ$ experiment is designed to measure the lifetime $τ_{n}$ of the free neutron by trapping ultracold neutrons (UCN) in a magneto-gravitational trap. An asymmetric bowl-shaped NdFeB magnet Halbach array confines low-field-seeking UCN within the apparatus, and a set of electromagnetic coils in a toroidal geometry provide a background "holding" field to eliminate depolarization-induced UCN loss caused by magnetic field nodes. We present a measurement of the storage time $τ_{store}$ of the trap by storing UCN for various times, and counting the survivors. The data are consistent with a single exponential decay, and we find $τ_{store}=860\pm19$ s: within $1 σ$ of current global averages for $τ_{n}$. The storage time with the holding field deactiveated is found to be $τ_{store}=470 \pm 160$ s; this decreased storage time is due to the loss of UCN which undergo Majorana spin-flips while being stored. We discuss plans to increase the statistical sensitivity of the measurement and investigate potential systematic effects.

preprint2013arXiv

Trapped-ion decay spectroscopy towards the determination of ground-state components of double-beta decay matrix elements

A new technique has been developed at TRIUMF's TITAN facility to perform in-trap decay spectroscopy. The aim of this technique is to eventually measure weak electron capture branching ratios (ECBRs) and by this to consequently determine GT matrix elements of $ββ$ decaying nuclei. These branching ratios provide important input to the theoretical description of these decays. The feasibility and power of the technique is demonstrated by measuring the ECBR of $^{124}$Cs.

preprint2012arXiv

High-Precision Measurement of the 19Ne Half-Life and Implications for Right-Handed Weak Currents

We report a precise determination of the 19Ne half-life to be $T_{1/2} = 17.262 \pm 0.007$ s. This result disagrees with the most recent precision measurements and is important for placing bounds on predicted right-handed interactions that are absent in the current Standard Model. We are able to identify and disentangle two competing systematic effects that influence the accuracy of such measurements. Our findings prompt a reassessment of results from previous high-precision lifetime measurements that used similar equipment and methods.

preprint2010arXiv

Polarized Neutron $β$-Decay: the Proton Asymmetry and Recoil-Order Currents

We present an analytic, recoil-order calculation of the proton asymmetry from polarized neutron $β$-decay. The differential decay rate in terms of electron energy and proton direction follows, parametrized in terms of the most general Lorentz-invariant hadron current coupled to a left-handed lepton current. Implications for experimental efforts to measure recoil-order currents are discussed.