Source author record

A. R. Young

A. R. Young appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

43works
9topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

43 published item(s)

preprint2026arXiv

Detection of ultracold neutrons with powdered scintillator screens

Zinc sulfide (ZnS:Ag) scintillators coated with a thin 10B layer are widely used for ultracold neutron (UCN) detection, but their application is limited by long decay times and significant phosphorescence. We investigated two possible replacement scintillators: yttrium aluminum perovskite (YAP:Ce) and lutetium ttrium orthosilicate (LYSO:Ce). Both exhibit decay times on the order of 30-40 ns, which can help reduce dead time in high-count-rate experiments. YAP:Ce showed approximately 60% lower phosphorescence than ZnS:Ag after 2 days and detected about 20% more UCN. In contrast, LYSO:Ce exhibited higher phosphorescence and produced fewer UCN counts compared to both ZnS:Ag and YAP:Ce. While both tested scintillators are capable UCN detectors, YAP:Ce consistently outperformed LYSO:Ce across all measured performance metrics.

preprint2022arXiv

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalyses of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. The new measurement gives a free neutron lifetime of . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

preprint2019arXiv

A next-generation inverse-geometry spallation-driven ultracold neutron source

The physics model of a next-generation spallation-driven high-current ultracold neutron (UCN) source capable of delivering an extracted UCN rate of around an-order-of-magnitude higher than the strongest proposed sources, and around three-orders-of-magnitude higher than existing sources, is presented. This UCN-current-optimized source would dramatically improve cutting-edge UCN measurements that are currently statistically limited. A novel "Inverse Geometry" design is used with 40 L of superfluid $^4$He (He-II), which acts as a converter of cold neutrons (CNs) to UCNs, cooled with state-of-the-art sub-cooled cryogenic technology to $\sim$1.6 K. Our design is optimized for a 100 W maximum heat load constraint on the He-II and its vessel. In our geometry, the spallation target is wrapped symmetrically around the UCN converter to permit raster scanning the proton beam over a relatively large volume of tungsten spallation target to reduce the demand on the cooling requirements, which makes it reasonable to assume that water edge-cooling only is sufficient. Our design is refined in several steps to reach $P_{UCN}=2.1\times10^9\,/$s under our other restriction of 1 MW maximum available proton beam power. We then study effects of the He-II scattering kernel as well as reductions in $P_{UCN}$ due to pressurization to reach $P_{UCN}=1.8\times10^9\,/$s. Finally, we provide a design for the UCN extraction system that takes into account the required He-II heat transport properties and implementation of a He-II containment foil that allows UCN transmission. We estimate a total useful UCN current from our source of $R_{use}=5\times10^8\,/$s from a 18 cm diameter guide 5 m from the source. Under a conservative "no return" approximation, this rate can produce an extracted density of $>1\times10^4\,/$cm$^3$ in $<$1000~L external experimental volumes with a $^{58}$Ni (335 neV) cut-off potential.

preprint2019arXiv

Final results for the neutron $β$-asymmetry parameter $A_0$ from the UCNA experiment

The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.

preprint2019arXiv

Improved limits on Fierz Interference using asymmetry measurements from the UCNA experiment

The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the $β$-decay asymmetry parameter, $A_0$, for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their $β$-decay electrons are detected with $\approx 4π$ acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sensitivity to $b_{n}$, the Fierz interference term in the neutron $β$-decay rate. In this work, we determine $b_{n}$ from the energy dependence of $A_0$ using the data taken during the UCNA 2011-2013 run. In addition, we present the same type of analysis using the earlier 2010 $A$ dataset. Motivated by improved statistics and comparable systematic errors compared to the 2010 data-taking run, we present a new $b_{n}$ measurement using the weighted average of our asymmetry dataset fits, to obtain $b_{n} = 0.066 \pm 0.041_{\text{stat}} \pm 0.024_{\text{syst}}$ which corresponds to a limit of $-0.012 < b_{n} < 0.144$ at the 90% confidence level.

preprint2019arXiv

The neutron electric dipole moment experiment at the Spallation Neutron Source

Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized $^3$He, and superfluid $^4$He will be exploited to provide a sensitivity to $\sim 10^{-28}\,e{\rm \,\cdot\, cm}$. Our cryogenic apparatus will deploy two small ($3\,{\rm L}$) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our $^3$He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of "critical component demonstration," our collaboration transitioned to a "large scale integration" phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.

preprint2016arXiv

Measurement of spin-flip probabilities for ultracold neutrons interacting with nickel phosphorus coated surfaces

We report a measurement of the spin-flip probabilities for ultracold neutrons interacting with surfaces coated with nickel phosphorus. For 50~$μ$m thick nickel phosphorus coated on stainless steel, the spin-flip probability per bounce was found to be $β_{\rm NiP\;on\;SS} = (3.3^{+1.8}_{-5.6}) \times 10^{-6}$. For 50~$μ$m thick nickel phosphorus coated on aluminum, the spin-flip probability per bounce was found to be $β_{\rm NiP\;on\;Al} = (3.6^{+2.1}_{-5.9}) \times 10^{-6}$. For the copper guide used as reference, the spin flip probability per bounce was found to be $β_{\rm Cu} = (6.7^{+5.0}_{-2.5}) \times 10^{-6}$. The results on the nickel phosphorus-coated surfaces may be interpreted as upper limits, yielding $β_{\rm NiP\;on\;SS} < 6.2 \times 10^{-6}$ (90\% C.L.) and $β_{\rm NiP\;on\;Al} < 7.0 \times 10^{-6}$ (90\% C.L.) for 50~$μ$m thick nickel phosphorus coated on stainless steel and 50~$μ$m thick nickel phosphorus coated on aluminum, respectively. Nickel phosphorus coated stainless steel or aluminum provides a solution when low-cost, mechanically robust, and non-depolarizing UCN guides with a high-Fermi-potential are needed.

preprint2016arXiv

Neutron Limit on the Strongly-Coupled Chameleon Field

The physical origin of the dark energy that causes the accelerated expansion rate of the universe is one of the major open questions of cosmology. One set of theories postulates the existence of a self-interacting scalar field for dark energy coupling to matter. In the chameleon dark energy theory, this coupling induces a screening mechanism such that the field amplitude is nonzero in empty space but is greatly suppressed in regions of terrestrial matter density. However measurements performed under appropriate vacuum conditions can enable the chameleon field to appear in the apparatus, where it can be subjected to laboratory experiments. Here we report the most stringent upper bound on the free neutron-chameleon coupling in the strongly-coupled limit of the chameleon theory using neutron interferometric techniques. Our experiment sought the chameleon field through the relative phase shift it would induce along one of the neutron paths inside a perfect crystal neutron interferometer. The amplitude of the chameleon field was actively modulated by varying the millibar pressures inside a dual-chamber aluminum cell. We report a 95% confidence level upper bound on the neutron-chameleon coupling $β$ ranging from $β< 4.7\times 10^6$ for a Ratra-Peebles index of n = 1 in the nonlinear scalar field potential to $β< 2.4\times 10^7$ for n = 6, one order of magnitude more sensitive than the most recent free neutron limit for intermediate n. Similar experiments can explore the full parameter range for chameleon dark energy in the foreseeable future.

preprint2015arXiv

The Majorana Parts Tracking Database

The Majorana Demonstrator is an ultra-low background physics experiment searching for the neutrinoless double beta decay of $^{76}$Ge. The Majorana Parts Tracking Database is used to record the history of components used in the construction of the Demonstrator. The tracking implementation takes a novel approach based on the schema-free database technology CouchDB. Transportation, storage, and processes undergone by parts such as machining or cleaning are linked to part records. Tracking parts provides a great logistics benefit and an important quality assurance reference during construction. In addition, the location history of parts provides an estimate of their exposure to cosmic radiation. A web application for data entry and a radiation exposure calculator have been developed as tools for achieving the extreme radio-purity required for this rare decay search.

preprint2014arXiv

A Dark Matter Search with MALBEK

The MAJORANA DEMONSTRATOR is an array of natural and enriched high purity germanium detectors that will search for the neutrinoless double-beta decay of 76-Ge and perform a search for weakly interacting massive particles (WIMPs) with masses below 10 GeV. As part of the MAJORANA research and development efforts, we have deployed a modified, low-background broad energy germanium detector at the Kimballton Underground Research Facility. With its sub-keV energy threshold, this detector is sensitive to potential non-Standard Model physics, including interactions with WIMPs. We discuss the backgrounds present in the WIMP region of interest and explore the impact of slow surface event contamination when searching for a WIMP signal.

preprint2014arXiv

A search for bremsstrahlung solar axions using the Majorana low-background BEGe detector at Kimballton (MALBEK)

A low-background, high-purity germanium detector has been used to search for evidence of low-energy, bremsstrahlung-generated solar axions. An upper bound of $1.36\times 10^{-11}$ $(95% CL)$ is placed on the direct coupling of DFSZ model axions to electrons. The prospects for the sensitivity of the Majorana Demonstrator array of point-contact germanium detectors to solar axions are discussed in the context of the model-independent annual modulation due to the seasonal variation of the earth-sun distance.

preprint2014arXiv

Background Model for the Majorana Demonstrator

The Majorana Collaboration is constructing a system containing 40 kg of HPGe detectors to demonstrate the feasibility and potential of a future tonne-scale experiment capable of probing the neutrino mass scale in the inverted-hierarchy region. To realize this, a major goal of the Majorana Demonstrator is to demonstrate a path forward to achieving a background rate at or below 1 cnt/(ROI-t-y) in the 4 keV region of interest around the Q-value at 2039 keV. This goal is pursued through a combination of a significant reduction of radioactive impurities in construction materials with analytical methods for background rejection, for example using powerful pulse shape analysis techniques profiting from the p-type point contact HPGe detectors technology. The effectiveness of these methods is assessed using simulations of the different background components whose purity levels are constrained from radioassay measurements.

preprint2014arXiv

Determination of the Free Neutron Lifetime

We present the status of current US experimental efforts to measure the lifetime of the free neutron by the "beam" and "bottle" methods. BBN nucleosynthesis models require accurate measurements with 1 second uncertainties, which are currently feasible. For tests of physics beyond the standard model, future efforts will need to achieve uncertainties well below 1 second. We outline paths achieve both.

preprint2014arXiv

Measurement of the half-life of the T=$\frac{1}{2}$ mirror decay of $^{19}$Ne and its implication on physics beyond the standard model

The $\frac{1}{2}^+ \rightarrow \frac{1}{2}^+$ superallowed mixed mirror decay of $^{19}$Ne to $^{19}$F is excellently suited for high precision studies of the weak interaction. However, there is some disagreement on the value of the half-life. In a new measurement we have determined this quantity to be $T_{1/2}$ = $17.2832 \pm 0.0051_{(stat)}$ $\pm 0.0066_{(sys)}$ s, which differs from the previous world average by 3 standard deviations. The impact of this measurement on limits for physics beyond the standard model such as the presence of tensor currents is discussed.

preprint2014arXiv

Radial distribution of charged particles in a magnetic field

The radial spread of charged particles emitted from a point source in a magnetic field is a potential source of systematic error for any experiment where magnetic fields guide charged particles to detectors with finite size. Assuming uniform probability as a function of the phase along the particle's helical trajectory, an analytic solution for the radial probability distribution function follows which applies to experiments in which particles are generated throughout a volume that spans a sufficient length along the axis of a homogeneous magnetic field. This approach leads to the same result as a different derivation given by Dubbers et al. But the constant phase approximation does not strictly apply to finite source volumes or fixed positions, which lead to local maxima in the radial distribution of emitted particles at the plane of the detector. A simple method is given to calculate such distributions, then the effect is demonstrated with data from a $^{207}$Bi electron-conversion source in the superconducting solenoid magnet spectrometer of the Ultracold Neutron facility at the Los Alamos Neutron Science Center. Potential future applications of this effect are discussed.

preprint2014arXiv

Testing the Ge detectors for the MAJORANA DEMONSTRATOR

High purity germanium (HPGe) crystals will be used for the MAJORANA DEMONSTRATOR, where they serve as both the source and the detector for neutrinoless double beta decay. It is crucial for the experiment to understand the performance of the HPGe crystals. A variety of crystal properties are being investigated, including basic properties such as energy resolution, efficiency, uniformity, capacitance, leakage current and crystal axis orientation, as well as more sophisticated properties, e.g. pulse shapes and dead layer and transition layer distributions. In this paper, we will present our measurements that characterize the HPGe crystals. We will also discuss our simulation package for the detector characterization setup, and show that additional information can be extracted from data-simulation comparisons.

preprint2013arXiv

A Segmented, Enriched N-type Germanium Detector for Neutrinoless Double Beta-Decay Experiments

We present data characterizing the performance of the first segmented, N-type Ge detector, isotopically enriched to 85% $^{76}$Ge. This detector, based on the Ortec PT6x2 design and referred to as SEGA (Segmented, Enriched Germanium Assembly), was developed as a possible prototype for neutrinoless double beta-decay measurements by the {\sc Majorana} collaboration. We present some of the general characteristics (including bias potential, efficiency, leakage current, and integral cross-talk) for this detector in its temporary cryostat. We also present an analysis of the resolution of the detector, and demonstrate that for all but two segments there is at least one channel that reaches the {\sc Majorana} resolution goal below 4 keV FWHM at 2039 keV, and all channels are below 4.5 keV FWHM.

preprint2013arXiv

Baryon Number Violation

This report, prepared for the Community Planning Study - Snowmass 2013 - summarizes the theoretical motivations and the experimental efforts to search for baryon number violation, focussing on nucleon decay and neutron-antineutron oscillations. Present and future nucleon decay search experiments using large underground detectors, as well as planned neutron-antineutron oscillation search experiments with free neutron beams are highlighted.

preprint2013arXiv

Depth Requirements for a Tonne-scale 76Ge Neutrinoless Double-beta Decay Experiment

Neutrinoless double-beta decay experiments can potentially determine the Majorana or Dirac nature of the neutrino, and aid in understanding the neutrino absolute mass scale and hierarchy. Future 76Ge-based searches target a half-life sensitivity of >10^27 y to explore the inverted neutrino mass hierarchy. Reaching this sensitivity will require a background rate of <1 count tonne^-1 y^-1 in a 4-keV-wide spectral region of interest surrounding the Q value of the decay. We investigate the overburden required to reach this background goal in a tonne-scale experiment with a compact (copper and lead) shield based on Monte Carlo calculations of cosmic-ray background rates. We find that, in light of the presently large uncertainties in these types of calculations, a site with an underground depth >~5200 mwe is required for a tonne-scale experiment with a compact shield similar to the planned 40-kg MAJORANA DEMONSTRATOR. The required overburden is highly dependent on the chosen shielding configuration and could be relaxed significantly if, for example, a liquid cryogen and water shield, or an active neutron shield were employed. Operation of the MAJORANA DEMONSTRATOR and GERDA detectors will serve to reduce the uncertainties on cosmic-ray background rates and will impact the choice of shielding style and location for a future tonne-scale experiment. 4/2013: The peer review process revealed that one of the veto rejection factors (the factor-of-4 described on p12) needs to be better established. Our reevaluation of this parameter to date has not yielded strong support for the value stated in the manuscript, and we require further study to develop a solid estimate. This further study will supersede the work described in this manuscript, and may or may not lead to the same conclusion regarding the ~>5200 mwe requirement for future tonne-scale 76Ge neutrinoless double beta decay experiments.

preprint2013arXiv

Measurements of ultracold neutron upscattering and absorption in polyethylene and vanadium

The study of neutron cross sections for elements used as efficient ``absorbers'' of ultracold neutrons (UCN) is crucial for many precision experiments in nuclear and particle physics, cosmology and gravity. In this context, ``absorption'' includes both the capture and upscattering of neutrons to the energies above the UCN energy region. The available data, especially for hydrogen, do not agree between themselves or with the theory. In this report we describe measurements performed at the Los Alamos National Laboratory UCN facility of the UCN upscattering cross sections for vanadium and for hydrogen in CH$_2$ using simultaneous measurements of the radiative capture cross sections for these elements. We measured $σ_{up}=1972\pm130$ b for hydrogen in CH$_2$, which is below theoretical expectations, and $σ_{up} < 25\pm9$ b for vanadium, in agreement with the expectation for the neutron heating by thermal excitations in solids.

preprint2013arXiv

Storage of ultracold neutrons in the UCN$τ$ magneto-gravitational trap

The UCN$τ$ experiment is designed to measure the lifetime $τ_{n}$ of the free neutron by trapping ultracold neutrons (UCN) in a magneto-gravitational trap. An asymmetric bowl-shaped NdFeB magnet Halbach array confines low-field-seeking UCN within the apparatus, and a set of electromagnetic coils in a toroidal geometry provide a background "holding" field to eliminate depolarization-induced UCN loss caused by magnetic field nodes. We present a measurement of the storage time $τ_{store}$ of the trap by storing UCN for various times, and counting the survivors. The data are consistent with a single exponential decay, and we find $τ_{store}=860\pm19$ s: within $1 σ$ of current global averages for $τ_{n}$. The storage time with the holding field deactiveated is found to be $τ_{store}=470 \pm 160$ s; this decreased storage time is due to the loss of UCN which undergo Majorana spin-flips while being stored. We discuss plans to increase the statistical sensitivity of the measurement and investigate potential systematic effects.

preprint2013arXiv

The {\sc Majorana Demonstrator} Neutrinoless Double-Beta Decay Experiment

The {\sc Majorana Demonstrator will search for the neutrinoless double-beta decay of the isotope Ge-76 with a mixed array of enriched and natural germanium detectors. The observation of this rare decay would indicate the neutrino is its own antiparticle, demonstrate that lepton number is not conserved, and provide information on the absolute mass scale of the neutrino. The {\sc Demonstrator} is being assembled at the 4850-foot level of the Sanford Underground Research Facility in Lead, South Dakota. The array will be situated in a low-background environment and surrounded by passive and active shielding. Here we describe the science goals of the {\sc Demonstrator} and the details of its design.

preprint2013arXiv

The MAJORANA DEMONSTRATOR: A Search for Neutrinoless Double-beta Decay of Germanium-76

The {\sc Majorana} collaboration is searching for neutrinoless double beta decay using $^{76}$Ge, which has been shown to have a number of advantages in terms of sensitivities and backgrounds. The observation of neutrinoless double-beta decay would show that lepton number is violated and that neutrinos are Majorana particles and would simultaneously provide information on neutrino mass. Attaining sensitivities for neutrino masses in the inverted hierarchy region, $15 - 50$ meV, will require large, tonne-scale detectors with extremely low backgrounds, at the level of $\sim$1 count/t-y or lower in the region of the signal. The {\sc Majorana} collaboration, with funding support from DOE Office of Nuclear Physics and NSF Particle Astrophysics, is constructing the {\sc Demonstrator}, an array consisting of 40 kg of p-type point-contact high-purity germanium (HPGe) detectors, of which $\sim$30 kg will be enriched to 87% in $^{76}$Ge. The {\sc Demonstrator} is being constructed in a clean room laboratory facility at the 4850' level (4300 m.w.e.) of the Sanford Underground Research Facility (SURF) in Lead, SD. It utilizes a compact graded shield approach with the inner portion consisting of ultra-clean Cu that is being electroformed and machined underground. The primary aim of the {\sc Demonstrator} is to show the feasibility of a future tonne-scale measurement in terms of backgrounds and scalability.

preprint2013arXiv

The Upscattering of Ultracold Neutrons from the polymer $[C_6 H_{12}]_n$

It is generally accepted that the main cause of ultracold neutron (UCN) losses in storage traps is the upscattering to the thermal energy range by hydrogen adsorbed on the surface of the trap walls. However, the data on which this conclusion is based are poor and contradictory. Here, we report a measurement, performed at the Los Alamos National Laboratory UCN source, of the average energy of the flux of upscattered neutrons after the interaction of UCN with hydrogen bound in semicrystalline polymer PMP (tradename TPX), [C$_{6}$H$_{12}$]$_n$. Our analysis, performed with the MCNP code based on the application of the neutron scattering law to UCN upscattered by bound hydrogen in semicrystalline polyethylene, [C$_{2}$H$_{4}$]$_n$, leads us to a flux average energy value of 26$\pm3$ meV in contradiction with previously reported experimental values of 10 to 13 meV and in agreement with the theoretical models of neutron heating implemented in the MCNP code.

preprint2012arXiv

Characteristics of Signals Originating Near the Lithium-Diffused N+ Contact of High Purity Germanium P-Type Point Contact Detectors

A study of signals originating near the lithium-diffused n+ contact of p-type point contact (PPC) high purity germanium detectors (HPGe) is presented. The transition region between the active germanium and the fully dead layer of the n+ contact is examined. Energy depositions in this transition region are shown to result in partial charge collection. This provides a mechanism for events with a well defined energy to contribute to the continuum of the energy spectrum at lower energies. A novel technique to quantify the contribution from this source of background is introduced. Experiments that operate germanium detectors with a very low energy threshold may benefit from the methods presented herein.

preprint2012arXiv

Measurement of the neutron $β$-asymmetry parameter $A_0$ with ultracold neutrons

We present a detailed report of a measurement of the neutron $β$-asymmetry parameter $A_0$, the parity-violating angular correlation between the neutron spin and the decay electron momentum, performed with polarized ultracold neutrons (UCN). UCN were extracted from a pulsed spallation solid deuterium source and polarized via transport through a 7-T magnetic field. The polarized UCN were then transported through an adiabatic-fast-passage spin-flipper field region, prior to storage in a cylindrical decay volume situated within a 1-T $2 \times 2π$ solenoidal spectrometer. The asymmetry was extracted from measurements of the decay electrons in multiwire proportional chamber and plastic scintillator detector packages located on both ends of the spectrometer. From an analysis of data acquired during runs in 2008 and 2009, we report $A_0 = -0.11966 \pm 0.00089_{-0.00140} ^{+0.00123}$, from which we extract a value for the ratio of the weak axial-vector and vector coupling constants of the nucleon, $λ= g_A/g_V = -1.27590 \pm 0.00239_{-0.00377}^{+0.00331}$. Complete details of the analysis are presented.

preprint2012arXiv

The MAJORANA DEMONSTRATOR: Progress towards showing the feasibility of a tonne-scale 76Ge neutrinoless double-beta decay experiment

The MAJORANA DEMONSTRATOR will search for the neutrinoless double-beta decay of the 76Ge isotope with a mixed array of enriched and natural germanium detectors. The observation of this rare decay would indicate the neutrino is its own anti-particle, demonstrate that lepton number is not conserved, and provide information on the absolute mass-scale of the neutrino. The DEMONSTRATOR is being assembled at the 4850 foot level of the Sanford Underground Research Facility in Lead, South Dakota. The array will be contained in a low-background environment and surrounded by passive and active shielding. The goals for the DEMONSTRATOR are: demonstrating a background rate less than 3 t$^{-1}$ y$^{-1}$ in the 4 keV region of interest (ROI) surrounding the 2039 keV 76Ge endpoint energy; establishing the technology required to build a tonne-scale germanium based double-beta decay experiment; testing the recent claim of observation of neutrinoless double-beta decay [H. V. Klapdor-Kleingrothaus and I. V. Krivosheina, Mod. Phys. Lett. A21, 1547 (2006)]; and performing a direct search for light WIMPs (3-10 GeV).

preprint2011arXiv

Search for the Neutron Electric Dipole Moment: Contributions from the Triangle Universities Nuclear Laboratory

A significant fraction of the research effort at the Triangle Universities Nuclear Laboratory (TUNL) focuses on weak interaction studies and searches for physics beyond the Standard Model. One major effort is the development of a new experimental technique to search for the neutron electric dipole moment (nEDM) that offers the potential for a factor of 100 increase in sensitivity over existing measurements. The search for this moment has the potential to reveal new sources of time reversal (T) and charge-conjugation-and-parity (CP) violation and to challenge calculations that propose extensions to the Standard Model. We provide a brief overview of the experiment as a whole and discuss the work underway at TUNL as part of this effort.

preprint2011arXiv

The Majorana Demonstrator

A brief review of the history and neutrino physics of double beta decay is given. A description of the MAJORANA DEMONSTRATOR research and development program including background reduction techniques is presented in some detail. The application of point contact (PC) detectors to the experiment is discussed, including the effectiveness of pulse shape analysis. The predicted sensitivity of a PC detector array enriched to 86% in 76Ge is given.

preprint2011arXiv

The MAJORANA DEMONSTRATOR: A Search for Neutrinoless Double-beta Decay of Germanium-76

The observation of neutrinoless double-beta decay would determine whether the neutrino is a Majorana particle and provide information on the absolute scale of neutrino mass. The MAJORANA Collaboration is constructing the DEMONSTRATOR, an array of germanium detectors, to search for neutrinoless double-beta decay of 76-Ge. The DEMONSTRATOR will contain 40 kg of germanium; up to 30 kg will be enriched to 86% in 76-Ge. The DEMONSTRATOR will be deployed deep underground in an ultra-low-background shielded environment. Operation of the DEMONSTRATOR aims to determine whether a future tonne-scale germanium experiment can achieve a background goal of one count per tonne-year in a 4-keV region of interest around the 76-Ge neutrinoless double-beta decay Q-value of 2039 keV.

preprint2011arXiv

The Majorana experiment: an ultra-low background search for neutrinoless double-beta decay

The observation of neutrinoless double-beta decay would resolve the Majorana nature of the neutrino and could provide information on the absolute scale of the neutrino mass. The initial phase of the Majorana experiment, known as the Demonstrator, will house 40 kg of Ge in an ultra-low background shielded environment at the 4850' level of the Sanford Underground Laboratory in Lead, SD. The objective of the Demonstrator is to determine whether a future 1-tonne experiment can achieve a background goal of one count per tonne-year in a narrow region of interest around the 76Ge neutrinoless double-beta decay peak.

preprint2010arXiv

Astroparticle Physics with a Customized Low-Background Broad Energy Germanium Detector

The MAJORANA Collaboration is building the MAJORANA DEMONSTRATOR, a 60 kg array of high purity germanium detectors housed in an ultra-low background shield at the Sanford Underground Laboratory in Lead, SD. The MAJORANA DEMONSTRATOR will search for neutrinoless double-beta decay of 76Ge while demonstrating the feasibility of a tonne-scale experiment. It may also carry out a dark matter search in the 1-10 GeV/c^2 mass range. We have found that customized Broad Energy Germanium (BEGe) detectors produced by Canberra have several desirable features for a neutrinoless double-beta decay experiment, including low electronic noise, excellent pulse shape analysis capabilities, and simple fabrication. We have deployed a customized BEGe, the MAJORANA Low-Background BEGe at Kimballton (MALBEK), in a low-background cryostat and shield at the Kimballton Underground Research Facility in Virginia. This paper will focus on the detector characteristics and measurements that can be performed with such a radiation detector in a low-background environment.

preprint2010arXiv

Coherent Neutron Scattering in Polycrystalline Deuterium and its Implications for Ultracold Neutron Production

This paper presents a calculation of the neutron cross-sections in solid materials (used in practical neutron sources) with a large coherent scattering contribution. In particular, the dynamic structure function S(Q, $ω$) of polycrystalline ortho-D$_2$ is evaluated using a Monte-Carlo calculation that performs an average over scattering angles relative to crystal axes in random orientations. This method uses an analytical dispersion function with force constants derived from neutron scattering data of single crystal D$_2$ in the framework of an axially symmetric force tensor. The resulting two dimensional map of S(Q, $ω$) captures details of the phonon branches as well as the molecular rotations, that can be compared directly to data from inelastic neutron scattering on polycrystalline D$_2$. This high resolution information is used to calculate the absolute cross-sections of production and upscattering loss of ultracold neutron (UCN). The resulting scattering cross-sections are significantly different, especially for UCN upscattering, from the previous predictions using the approach centered on the incoherent approximation.

preprint2010arXiv

Determination of the Axial-Vector Weak Coupling Constant with Ultracold Neutrons

A precise measurement of the neutron decay $β$-asymmetry $A_0$ has been carried out using polarized ultracold neutrons (UCN) from the pulsed spallation UCN source at the Los Alamos Neutron Science Center (LANSCE). Combining data obtained in 2008 and 2009, we report $A_0 = -0.11966 \pm 0.00089_{-0.00140}^{+0.00123}$, from which we determine the ratio of the axial-vector to vector weak coupling of the nucleon $g_A/g_V = -1.27590_{-0.00445}^{+0.00409}$.

preprint2010arXiv

Ultracold Neutron Production in a Pulsed Neutron Beam Line

We present the results of an Ultracold neutron (UCN) production experiment in a pulsed neutron beam line at the Los Alamos Neutron Scattering Center. The experimental apparatus allows for a comprehensive set of measurements of UCN production as a function of target temperature, incident neutron energy, target volume, and applied magnetic field. However, the low counting statistics of the UCN signal expected can be overwhelmed by the large background associated with the scattering of the primary cold neutron flux that is required for UCN production. We have developed a background subtraction technique that takes advantage of the very different time-of-flight profiles between the UCN and the cold neutrons, in the pulsed beam. Using the unique timing structure, we can reliably extract the UCN signal. Solid ortho-D$_2$ is used to calibrate UCN transmission through the apparatus, which is designed primarily for studies of UCN production in solid O$_2$. In addition to setting the overall detection efficiency in the apparatus, UCN production data using solid D$_2$ suggest that the UCN upscattering cross-section is smaller than previous estimates, indicating the deficiency of the incoherent approximation widely used to estimate inelastic cross-sections in the thermal and cold regimes.

preprint2008arXiv

Nab: Measurement Principles, Apparatus and Uncertainties

The Nab collaboration will perform a precise measurement of 'a', the electron-neutrino correlation parameter, and 'b', the Fierz interference term in neutron beta decay, in the Fundamental Neutron Physics Beamline at the SNS, using a novel electric/magnetic field spectrometer and detector design. The experiment is aiming at the 10^{-3} accuracy level in (Delta a)/a, and will provide an independent measurement of lambda = G_A/G_V, the ratio of axial-vector to vector coupling constants of the nucleon. Nab also plans to perform the first ever measurement of 'b' in neutron decay, which will provide an independent limit on the tensor weak coupling.

preprint2003arXiv

An Apparatus to Control and Monitor the Para-D2 Concentration in a Solid Deuterium, Superthermal Source of Ultra-cold Neutrons

Controlling and measuring the concentration of para-D2 is an essential step toward realizing solid deuterium as an intense ultra-cold neutron (UCN) source. To this end, we implemented an experimental technique to convert para- to ortho-deuterium molecules by flowing D2 gas through a cryogenic cell filled with paramagnetic hydrous ferric oxide granules. This process efficiently reduced the para-D2 concentration from 33.3% to 1.5%. Rotational Raman spectroscopy was applied to measure the residual para-D2 contamination to better than 2 parts in 10^3, and the hydrogen contamination to 1 part in 10^3. We also contrast our optical technique to conventional thermal conductivity measurements of the para-D2 concentration, reporting some of the relevant strengths and weaknesses of our implementation of each technique.

preprint2002arXiv

Production of UCN by Downscattering in superfluid He4

Ultra-cold neutrons (UCN) are neutrons with energies so low they can be stored in material bottles and magnetic traps. They have been used to provide the currently most accurate experiments on the neutron life time and electric dipole moment. UCN can be produced in superfluid Helium at significantly higher densities than by other methods. The predominant production process is usually by one phonon emission which can only occur at a single incident neutron energy because of momentum and energy conservation. However UCN can also be produced by multiphonon processes. It is the purpose of this work to examine this multiphonon production of UCN. We look at several different incident neutron spectra, including cases where the multiphonon production is significant, and see how the relative importance of multiphonon production is influenced by the incident spectrum.