Source author record

A. T. Holley

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

11works
4topics
4close collaborators

Published work

11 publications

preprint2026arXiv

Detection of ultracold neutrons with powdered scintillator screens

Zinc sulfide (ZnS:Ag) scintillators coated with a thin 10B layer are widely used for ultracold neutron (UCN) detection, but their application is limited by long decay times and significant phosphorescence. We investigated two possible replacement scintillators: yttrium aluminum perovskite (YAP:Ce) and lutetium ttrium orthosilicate (LYSO:Ce). Both exhibit decay times on the order of 30-40 ns, which can help reduce dead time in high-count-rate experiments. YAP:Ce showed approximately 60% lower phosphorescence than ZnS:Ag after 2 days and detected about 20% more UCN. In contrast, LYSO:Ce exhibited higher phosphorescence and produced fewer UCN counts compared to both ZnS:Ag and YAP:Ce. While both tested scintillators are capable UCN detectors, YAP:Ce consistently outperformed LYSO:Ce across all measured performance metrics.

preprint2022arXiv

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalyses of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. The new measurement gives a free neutron lifetime of . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

preprint2019arXiv

Final results for the neutron ββ-asymmetry parameter A0A_0 from the UCNA experiment

The UCNA experiment was designed to measure the neutron ββ-asymmetry parameter A0A_0 using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for A0A_0 was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for A0A_0.

preprint2019arXiv

Improved limits on Fierz Interference using asymmetry measurements from the UCNA experiment

The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the ββ-decay asymmetry parameter, A0A_0, for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their ββ-decay electrons are detected with ≈4π\approx 4π acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sensitivity to bnb_{n}, the Fierz interference term in the neutron ββ-decay rate. In this work, we determine bnb_{n} from the energy dependence of A0A_0 using the data taken during the UCNA 2011-2013 run. In addition, we present the same type of analysis using the earlier 2010 AA dataset. Motivated by improved statistics and comparable systematic errors compared to the 2010 data-taking run, we present a new bnb_{n} measurement using the weighted average of our asymmetry dataset fits, to obtain bn=0.066±0.041stat±0.024systb_{n} = 0.066 \pm 0.041_{\text{stat}} \pm 0.024_{\text{syst}} which corresponds to a limit of −0.012<bn<0.144-0.012 < b_{n} < 0.144 at the 90% confidence level.

preprint2019arXiv

The neutron electric dipole moment experiment at the Spallation Neutron Source

Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized 3^3He, and superfluid 4^4He will be exploited to provide a sensitivity to ∼10−28 e ⋅ cm\sim 10^{-28}\,e{\rm \,\cdot\, cm}. Our cryogenic apparatus will deploy two small (3 L3\,{\rm L}) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our 3^3He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of "critical component demonstration," our collaboration transitioned to a "large scale integration" phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.

preprint2013arXiv

Measurements of ultracold neutron upscattering and absorption in polyethylene and vanadium

The study of neutron cross sections for elements used as efficient ``absorbers'' of ultracold neutrons (UCN) is crucial for many precision experiments in nuclear and particle physics, cosmology and gravity. In this context, ``absorption'' includes both the capture and upscattering of neutrons to the energies above the UCN energy region. The available data, especially for hydrogen, do not agree between themselves or with the theory. In this report we describe measurements performed at the Los Alamos National Laboratory UCN facility of the UCN upscattering cross sections for vanadium and for hydrogen in CH2_2 using simultaneous measurements of the radiative capture cross sections for these elements. We measured σup=1972±130σ_{up}=1972\pm130 b for hydrogen in CH2_2, which is below theoretical expectations, and σup<25±9σ_{up} < 25\pm9 b for vanadium, in agreement with the expectation for the neutron heating by thermal excitations in solids.

preprint2013arXiv

Storage of ultracold neutrons in the UCNττ magneto-gravitational trap

The UCNττ experiment is designed to measure the lifetime τnτ_{n} of the free neutron by trapping ultracold neutrons (UCN) in a magneto-gravitational trap. An asymmetric bowl-shaped NdFeB magnet Halbach array confines low-field-seeking UCN within the apparatus, and a set of electromagnetic coils in a toroidal geometry provide a background "holding" field to eliminate depolarization-induced UCN loss caused by magnetic field nodes. We present a measurement of the storage time τstoreτ_{store} of the trap by storing UCN for various times, and counting the survivors. The data are consistent with a single exponential decay, and we find τstore=860±19τ_{store}=860\pm19 s: within 1σ1 σ of current global averages for τnτ_{n}. The storage time with the holding field deactiveated is found to be τstore=470±160τ_{store}=470 \pm 160 s; this decreased storage time is due to the loss of UCN which undergo Majorana spin-flips while being stored. We discuss plans to increase the statistical sensitivity of the measurement and investigate potential systematic effects.

preprint2013arXiv

The Upscattering of Ultracold Neutrons from the polymer [C6H12]n[C_6 H_{12}]_n

It is generally accepted that the main cause of ultracold neutron (UCN) losses in storage traps is the upscattering to the thermal energy range by hydrogen adsorbed on the surface of the trap walls. However, the data on which this conclusion is based are poor and contradictory. Here, we report a measurement, performed at the Los Alamos National Laboratory UCN source, of the average energy of the flux of upscattered neutrons after the interaction of UCN with hydrogen bound in semicrystalline polymer PMP (tradename TPX), [C6_{6}H12_{12}]n_n. Our analysis, performed with the MCNP code based on the application of the neutron scattering law to UCN upscattered by bound hydrogen in semicrystalline polyethylene, [C2_{2}H4_{4}]n_n, leads us to a flux average energy value of 26±3\pm3 meV in contradiction with previously reported experimental values of 10 to 13 meV and in agreement with the theoretical models of neutron heating implemented in the MCNP code.

preprint2012arXiv

Measurement of the neutron ββ-asymmetry parameter A0A_0 with ultracold neutrons

We present a detailed report of a measurement of the neutron ββ-asymmetry parameter A0A_0, the parity-violating angular correlation between the neutron spin and the decay electron momentum, performed with polarized ultracold neutrons (UCN). UCN were extracted from a pulsed spallation solid deuterium source and polarized via transport through a 7-T magnetic field. The polarized UCN were then transported through an adiabatic-fast-passage spin-flipper field region, prior to storage in a cylindrical decay volume situated within a 1-T 2×2π2 \times 2π solenoidal spectrometer. The asymmetry was extracted from measurements of the decay electrons in multiwire proportional chamber and plastic scintillator detector packages located on both ends of the spectrometer. From an analysis of data acquired during runs in 2008 and 2009, we report A0=−0.11966±0.00089−0.00140+0.00123A_0 = -0.11966 \pm 0.00089_{-0.00140} ^{+0.00123}, from which we extract a value for the ratio of the weak axial-vector and vector coupling constants of the nucleon, λ=gA/gV=−1.27590±0.00239−0.00377+0.00331λ= g_A/g_V = -1.27590 \pm 0.00239_{-0.00377}^{+0.00331}. Complete details of the analysis are presented.

preprint2010arXiv

Determination of the Axial-Vector Weak Coupling Constant with Ultracold Neutrons

A precise measurement of the neutron decay ββ-asymmetry A0A_0 has been carried out using polarized ultracold neutrons (UCN) from the pulsed spallation UCN source at the Los Alamos Neutron Science Center (LANSCE). Combining data obtained in 2008 and 2009, we report A0=−0.11966±0.00089−0.00140+0.00123A_0 = -0.11966 \pm 0.00089_{-0.00140}^{+0.00123}, from which we determine the ratio of the axial-vector to vector weak coupling of the nucleon gA/gV=−1.27590−0.00445+0.00409g_A/g_V = -1.27590_{-0.00445}^{+0.00409}.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.