Source author record

S. Ivanov

S. Ivanov appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

12works
12topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

12 published item(s)

preprint2022arXiv

Commissioning of the PADME experiment with a positron beam

The PADME experiment is designed to search for a hypothetical dark photon $A^{\prime}$ produced in positron-electron annihilation using a bunched positron beam at the Beam Test Facility of the INFN Laboratori Nazionali di Frascati. The expected sensitivity to the $A^{\prime}$-photon mixing parameter $ε$ is 10$^{-3}$, for $A^{\prime}$ mass $\le$ 23.5 MeV/$c^{2}$ after collecting $\sim 10^{13}$ positrons-on-target. This paper presents the PADME detector status after commissioning in July 2019. In addition, the software algorithms employed to reconstruct physics objects, such as photons and charged particles, and the calibration procedures adopted are illustrated in detail. The results show that the experimental apparatus reaches the design performance, and is able to identify and measure standard electromagnetic processes, such as positron Bremsstrahlung, electron-positron annihilation into two photons.

preprint2022arXiv

The PADME beam line Monte Carlo simulation

The PADME experiment at the DA$Φ$NE Beam-Test Facility (BTF) of the INFN Laboratory of Frascati is designed to search for invisible decays of dark sector particles produced in electron-positron annihilation events with a positron beam and a thin fixed target, by measuring the missing mass of single-photon final states. The presence of backgrounds originating from beam halo particles can significantly reduce the sensitivity of the experiment. To thoroughly understand the origin of the beam background contribution, a detailed Geant4-based Monte Carlo simulation has been developed, containing a full description of the detector together with the beam line and its optical elements. This simulation allows the full interactions of each particle to be described, both during beam line transport and during detection, a possibility which represents an innovative way to obtain reliable background predictions

preprint2016arXiv

Neutron lifetime measurements and effective spectral cleaning with an ultracold neutron trap using a vertical Halbach octupole permanent magnet array

Ultracold neutron (UCN) storage measurements were made in a trap constructed from a 1.3 T Halbach Octupole PErmanent (HOPE) magnet array aligned vertically, using the TES-port of the PF2 source at the Institut Laue-Langevin. A mechanical UCN valve at the bottom of the trap was used for filling and emptying. This valve was covered with Fomblin grease to induce non-specular reflections and was used in combination with a movable polyethylene UCN remover inserted from the top for cleaning of above-threshold UCNs. Loss due to UCN depolarization was suppressed with a minimum 2 mT bias field. Without using the UCN remover, a total storage time constant of $(712 \pm 19)$ s was observed; with the remover inserted for 80 s and used at either 80 cm or 65 cm from the bottom of the trap, time constants of $(824 \pm 32)$ s and $(835 \pm 36)$ s were observed. Combining the latter two values, a neutron lifetime of $τ_{\rm n} = (887 \pm 39)$ s is extracted after primarily correcting for losses at the UCN valve. The time constants of the UCN population during cleaning were observed and compared to calculations based on UCN kinetic theory as well as Monte-Carlo studies. These calculations are used to predict above-threshold populations of $\sim 5\%$, $\sim 0.5\%$ and $\sim 10^{-12}\%$ remaining after cleaning in the no remover, 80~cm remover and 65~cm remover measurements. Thus, by using a non-specular reflector covering the entire bottom of the trap and a remover at the top of the trap, we have established an effective cleaning procedure for removing a major systematic effect in high-precision $τ_{\rm n}$ experiments with magnetically stored UCNs.

preprint2016arXiv

Ultracold neutron production and up-scattering in superfluid helium between 1.1 K and 2.4 K

Ultracold neutrons (UCNs) were produced in a 4 liter volume of superfluid helium using the PF1B cold neutron beam facility at the Institut Laue-Langevin and then extracted to a detector at room temperature. With a converter temperature of 1.08 K the number of accumulated UCNs was counted to be $91,\!700 \pm 300$. From this, we derive a volumetric UCN production rate of $(6.9 \pm 1.7)\,\mathrm{cm^{-3}\,s^{-1}}$, which includes a correction for losses in the converter during UCN extraction caused by a short storage time, but not accounting for UCN transport and detection efficiencies. The up-scattering rate of UCNs due to excitations in the superfluid was studied by scanning the temperature between 1.2-2.4 K. Using the temperature-dependent UCN production rate calculated from inelastic neutron scattering data in the analysis, the only UCN up-scattering process found to be present was from two-phonon scattering. Our analysis rules out contributions from the other scattering processes to $\lesssim 10\%$ of their predicted levels.

preprint2016arXiv

Versatile microwave-driven trapped ion spin system for quantum information processing

Using trapped atomic ions we demonstrate a tailored and versatile effective spin-system suitable for quantum simulations and universal quantum computation. By simply applying microwave pulses, selected spins can be decoupled from the remaining system and thus can serve as a quantum memory, while simultaneously, other coupled spins perform conditional quantum dynamics. Also, microwave pulses can change the sign of spin-spin couplings, as well as their effective strength, even during the course of a quantum algorithm. Taking advantage of the simultaneous long-range coupling between three spins a coherent quantum Fourier transform -- an essential building block for many quantum algorithms -- is efficiently realized. This approach, which is based on microwave-driven trapped ions and is complementary to laser-based methods, opens a new route to overcoming technical and physical challenges in the quest for a quantum simulator and a quantum computer.

preprint2015arXiv

A comparison of two magnetic ultra-cold neutron trapping concepts using a Halbach-octupole array

This paper describes a new magnetic trap for ultra-cold neutrons (UCNs) made from a 1.2 m long Halbach-octupole array of permanent magnets with an inner bore radius of 47 mm combined with an assembly of superconducting end coils and bias field solenoid. The use of the trap in a vertical, magneto-gravitational and a horizontal setup are compared in terms of the effective volume and ability to control key systematic effects that need to be addressed in high precision neutron lifetime measurements.

preprint2011arXiv

Diffraction of slow neutrons by holographic SiO_2 nanoparticle-polymer composite gratings

Diffraction experiments with holographic gratings recorded in SiO$_2$ nanoparticle-polymer composites have been carried out with slow neutrons. The influence of parameters such as nanoparticle concentration, grating thickness and grating spacing on the neutron-optical properties of such materials has been tested. Decay of the grating structure along the sample depth due to disturbance of the recording process becomes an issue at grating thicknesses of about 100 microns and larger. This limits the achievable diffraction efficiency for neutrons. As a solution to this problem, the Pendellösung interference effect in holographic gratings has been exploited to reach a diffraction efficiency of 83% for very cold neutrons.

preprint2002arXiv

Deformations of generalized calibrations and compact non-Kahler manifolds with vanishing first Chern class

We investigate the deformation theory of a class of generalized calibrations in Riemannian manifolds for which the tangent bundle has reduced structure group U(n), SU(n), G_2 and Spin(7). For this we use the property of the associated calibration form to be parallel with respect to a metric connection which may have non-vanishing torsion. In all these cases, we find that if there is a moduli space, then it is finite dimensional. We present various examples of generalized calibrations that include almost hermitian manifolds with structure group U(n) or SU(n), nearly parallel G_2 manifolds and group manifolds. We find that some Hopf fibrations are deformation families of generalized calibrations. In addition, we give sufficient conditions for a hermitian manifold (M,g,J) to admit Chern and Bismut connections with holonomy contained in SU(n). In particular we show that any connected sum of $k \geq 3$ copies of $S^3 \times S^3$ admits a hermitian structure for which the restricted holonomy of a Bismut connection is contained in SU(3).