Source author record

O. Zimmer

O. Zimmer appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

22works
8topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

22 published item(s)

preprint2022arXiv

Development of a High Intensity Neutron Source at the European Spallation Source: The HighNESS project

The European Spallation Source (ESS), presently under construction in Lund, Sweden, is a multidisciplinary international laboratory that will operate the world's most powerful pulsed neutron source. Supported by a 3M Euro Research and Innovation Action within the EU Horizon 2020 program, a design study (HighNESS) is now underway to develop a second neutron source below the spallation target. Compared to the first source, located above the spallation target and designed for high cold and thermal brightness, the new source will provide higher intensity, and a shift to longer wavelengths in the spectral regions of cold (2 /- 20 Å), very cold (VCN, 10 /- 120 Å), and ultra cold (UCN, > 500 Å) neutrons. The core of the second source will consist of a large liquid deuterium moderator to deliver a high flux of cold neutrons and to serve secondary VCN and UCN sources, for which different options are under study. The features of these new sources will boost several areas of condensed matter research and will provide unique opportunities in fundamental physics. Part of the HighNESS project is also dedicated to the development of future instruments that will make use of the new source and will complement the initial suite of instruments in construction at ESS. The HighNESS project started in October 2020. In this paper, the ongoing developments and the results obtained in the first year are described.

preprint2020arXiv

Development of High Intensity Neutron Source at the European Spallation Source

The European Spallation Source being constructed in Lund, Sweden will provide the user community with a neutron source of unprecedented brightness. By 2025, a suite of 15 instruments will be served by a high-brightness moderator system placed above the spallation target. The ESS infrastructure, consisting of the proton linac, the target station, and the instrument halls, allows for implementation of a second source below the spallation target. We propose to develop a second neutron source with a high-intensity moderator able to (1) deliver a larger total cold neutron flux, (2) provide high intensities at longer wavelengths in the spectral regions of Cold (4-10 Å), Very Cold (10-40 Å), and Ultra Cold (several 100 Å) neutrons, as opposed to Thermal and Cold neutrons delivered by the top moderator. Offering both unprecedented brilliance, flux, and spectral range in a single facility, this upgrade will make ESS the most versatile neutron source in the world and will further strengthen the leadership of Europe in neutron science. The new source will boost several areas of condensed matter research such as imaging and spin-echo, and will provide outstanding opportunities in fundamental physics investigations of the laws of nature at a precision unattainable anywhere else. At the heart of the proposed system is a volumetric liquid deuterium moderator. Based on proven technology, its performance will be optimized in a detailed engineering study. This moderator will be complemented by secondary sources to provide intense beams of Very- and Ultra-Cold Neutrons.

preprint2020arXiv

Experimental Search for Non-Newtonian Forces in the Nanometer Scale with Slow Neutrons

Improved limits for new gravity-like short-range interactions, in which a scattering potential is modeled by the Yukawa-type parametrization, have been obtained by measuring the angular distribution of 6 Å neutrons scattering from atomic xenon gas. We have collected approximately $1.4 \times 10^8$ small-angle neutron scattering events. The data are interpreted as no evidence of new forces and show improved upper limits on the coupling strength in the interaction range of $0.3$ nm to $9$ nm. These improved constraints are also interpreted as new limits for a model, in which a charge of the new forces is expressed as a linear combination of the baryon number and the lepton number.

preprint2020arXiv

Improved determination of the $β$-$\overlineν_e$ angular correlation coefficient $a$ in free neutron decay with the $a$SPECT spectrometer

We report on a precise measurement of the electron-antineutrino angular correlation ($a$ coefficient) in free neutron beta-decay from the $a$SPECT experiment. The $a$ coefficient is inferred from the recoil energy spectrum of the protons which are detected in 4$π$ by the $a$SPECT spectrometer using magnetic adiabatic collimation with an electrostatic filter. Data are presented from a 100 days run at the Institut Laue Langevin in 2013. The sources of systematic errors are considered and included in the final result. We obtain $a = -0.10430(84)$ which is the most precise measurement of the neutron $a$ coefficient to date. From this, the ratio of axial-vector to vector coupling constants is derived giving $|λ| = 1.2677(28)$.

preprint2016arXiv

Neutron lifetime measurements and effective spectral cleaning with an ultracold neutron trap using a vertical Halbach octupole permanent magnet array

Ultracold neutron (UCN) storage measurements were made in a trap constructed from a 1.3 T Halbach Octupole PErmanent (HOPE) magnet array aligned vertically, using the TES-port of the PF2 source at the Institut Laue-Langevin. A mechanical UCN valve at the bottom of the trap was used for filling and emptying. This valve was covered with Fomblin grease to induce non-specular reflections and was used in combination with a movable polyethylene UCN remover inserted from the top for cleaning of above-threshold UCNs. Loss due to UCN depolarization was suppressed with a minimum 2 mT bias field. Without using the UCN remover, a total storage time constant of $(712 \pm 19)$ s was observed; with the remover inserted for 80 s and used at either 80 cm or 65 cm from the bottom of the trap, time constants of $(824 \pm 32)$ s and $(835 \pm 36)$ s were observed. Combining the latter two values, a neutron lifetime of $τ_{\rm n} = (887 \pm 39)$ s is extracted after primarily correcting for losses at the UCN valve. The time constants of the UCN population during cleaning were observed and compared to calculations based on UCN kinetic theory as well as Monte-Carlo studies. These calculations are used to predict above-threshold populations of $\sim 5\%$, $\sim 0.5\%$ and $\sim 10^{-12}\%$ remaining after cleaning in the no remover, 80~cm remover and 65~cm remover measurements. Thus, by using a non-specular reflector covering the entire bottom of the trap and a remover at the top of the trap, we have established an effective cleaning procedure for removing a major systematic effect in high-precision $τ_{\rm n}$ experiments with magnetically stored UCNs.

preprint2016arXiv

Ultracold neutron production and up-scattering in superfluid helium between 1.1 K and 2.4 K

Ultracold neutrons (UCNs) were produced in a 4 liter volume of superfluid helium using the PF1B cold neutron beam facility at the Institut Laue-Langevin and then extracted to a detector at room temperature. With a converter temperature of 1.08 K the number of accumulated UCNs was counted to be $91,\!700 \pm 300$. From this, we derive a volumetric UCN production rate of $(6.9 \pm 1.7)\,\mathrm{cm^{-3}\,s^{-1}}$, which includes a correction for losses in the converter during UCN extraction caused by a short storage time, but not accounting for UCN transport and detection efficiencies. The up-scattering rate of UCNs due to excitations in the superfluid was studied by scanning the temperature between 1.2-2.4 K. Using the temperature-dependent UCN production rate calculated from inelastic neutron scattering data in the analysis, the only UCN up-scattering process found to be present was from two-phonon scattering. Our analysis rules out contributions from the other scattering processes to $\lesssim 10\%$ of their predicted levels.

preprint2015arXiv

A comparison of two magnetic ultra-cold neutron trapping concepts using a Halbach-octupole array

This paper describes a new magnetic trap for ultra-cold neutrons (UCNs) made from a 1.2 m long Halbach-octupole array of permanent magnets with an inner bore radius of 47 mm combined with an assembly of superconducting end coils and bias field solenoid. The use of the trap in a vertical, magneto-gravitational and a horizontal setup are compared in terms of the effective volume and ability to control key systematic effects that need to be addressed in high precision neutron lifetime measurements.

preprint2015arXiv

Experimental study of ultracold neutron production in pressurized superfluid helium

We have investigated experimentally the pressure dependence of the production of ultracold neutrons (UCN) in superfluid helium in the range from saturated vapor pressure to 20bar. A neutron velocity selector allowed the separation of underlying single-phonon and multiphonon pro- cesses by varying the incident cold neutron (CN) wavelength in the range from 3.5 to 10Å. The predicted pressure dependence of UCN production derived from inelastic neutron scattering data was confirmed for the single-phonon excitation. For multiphonon based UCN production we found no significant dependence on pressure whereas calculations from inelastic neutron scattering data predict an increase of 43(6)% at 20bar relative to saturated vapor pressure. From our data we conclude that applying pressure to superfluid helium does not increase the overall UCN production rate at a typical CN guide.

preprint2015arXiv

Neutrons on a surface of liquid helium

We investigate the possibility of ultracold neutron (UCN) storage in quantum states defined by the combined potentials of the Earth's gravity and the neutron optical repulsion by a horizontal surface of liquid helium. We analyse the stability of the lowest quantum state, which is most susceptible to perturbations due to surface excitations, against scattering by helium atoms in the vapor and by excitations of the liquid, comprised of ripplons, phonons and surfons. This is an unusual scattering problem since the kinetic energy of the neutron parallel to the surface may be much greater than the binding energies perpendicular. The total scattering time constant of these UCNs at 0.7 K is found to exceed one hour, and rapidly increasing with decreasing temperature. Such low scattering rates should enable high-precision measurements of the scheme of discrete energy levels, thus providing improved access to short-range gravity. The system might also be useful for neutron beta-decay experiments. We also sketch new experimental concepts for level population and trapping of UCNs above a flat horizontal mirror.

preprint2015arXiv

Ultracold neutron accumulation in a superfluid-helium converter with magnetic multipole reflector

We analyze accumulation of ultracold neutrons (UCN) in a superfluid-helium converter vessel surrounded by a magnetic multipole reflector. We solved the spin-dependent rate equation, employing formulas valid for adiabatic spin transport of trapped UCN in mechanical equilibrium. Results for saturation UCN densities are obtained in dependence of order and strength of the multipolar field. The addition of magnetic storage to neutron optical potentials can increase the density and energy of the low field seeking UCN produced and serves to mitigate the effects of wall losses on the source performance. It also can provide a highly polarized sample of UCN without need to polarize the neutron beam incident on the converter. This work was performed in preparation of the UCN source project SuperSUN at the ILL.

preprint2014arXiv

New measurements of neutron electric dipole moment with double chamber EDM spectrometer

The article presents results on neutron electric dipole moment measurements (EDM), made by ILL reactor using PNPI experimental installation. Double chamber magnetic resonance spectrometer with prolonged holding of ultra cold neutrons has been employed. The obtained results at 90% confidence level determine the upper limit for EDM neutron quantity equal to $|d_n| < 5.5 \cdot 10^{-26}$ e$ \cdot$cm.

preprint2014arXiv

New source for ultracold neutrons at the Institut Laue-Langevin

A new intense superthermal source for ultracold neutrons (UCN) has been installed at a dedicated beam line at the Institut Laue-Langevin. Incident neutrons with a wavelength of 0.89 nm are converted to UCN in a five liter volume filled with superfluid $^4$He at a temperature of about 0.7 K. The UCN can be extracted to room temperature experiments. We present the cryogenic setup of the source, a characterization of the cold neutron beam, and UCN production measurements, where a UCN density in the production volume of at least 55 per cm$^3$ was determined.

preprint2012arXiv

Polarized Neutron Laue Diffraction on a Crystal Containing Dynamically Polarized Proton Spins

We report on a polarized-neutron Laue diffraction experiment on a single crystal of neodynium doped lanthanum magnesium nitrate hydrate containing polarized proton spins. By using dynamic nuclear polarization to polarize the proton spins, we demonstrate that the intensities of the Bragg peaks can be enhanced or diminished significantly, whilst the incoherent background, due to proton spin disorder, is reduced. It follows that the method offers unique possibilities to tune continuously the contrast of the Bragg reflections and thereby represents a new tool for increasing substantially the signal-to-noise ratio in neutron diffraction patterns of hydrogenous matter.

preprint2011arXiv

Observability of an induced electric dipole moment of the neutron from nonlinear QED

It has been shown recently that a neutron placed in an external quasistatic electric field develops an induced electric dipole moment $\mathbf{p}_{\mathrm{IND}}$ due to quantum fluctuations in the QED vacuum. A feasible experiment which could detect such an effect is proposed and described here. It is shown that the peculiar angular dependence of $\mathbf{p}_{\mathrm{IND}}$ on the orientation of the neutron spin leads to a characteristic asymmetry in polarized neutron scattering by heavy nuclei. This asymmetry can be of the order of $10^{-3}$ for neutrons with epithermal energies. For thermalized neutrons from a hot moderator one still expects experimentally accessible values of the order of $10^{-4}$. The contribution of the induced effect to the neutron scattering length is expected to be only one order of magnitude smaller than that due to the neutron polarizability from its quark substructure. The experimental observation of this scattering asymmetry would be the first ever signal of nonlinearity in electrodynamics due to quantum fluctuations in the QED vacuum.

preprint2009arXiv

Search for macroscopic CP violating forces using a neutron EDM spectrometer

The search for CP violating forces between nucleons in the so-called axion window of force ranges lam between 2x10^-5 m and 0.02 m is interesting because only little experimental information is available there. Axion-like particles would induce a pseudo-magnetic field for neutrons close to bulk matter. A laboratory search investigates neutron spin precession close to a heavy mirror using ultracold neutrons in a magnetic resonance spectrometer. From the absence of a shift of the magnetic resonance we established new constraints on the coupling strength of axion-like particles in terms of the product gs x gp of scalar and pseudo-scalar dimensionless constants, as a function of the force range lam, gs x gp x lam^2 <= 2x10-21 [cm^2] (C.L.95%) for 10^-4 cm < lam < 1 cm. For 0.1 cm < lam < 1 cm previous limits are improved by 4 to 5 orders of magnitude.

preprint2009arXiv

Search for neutron - mirror neutron oscillations in a laboratory experiment with ultracold neutrons

Mirror matter is considered as a candidate for dark matter. In connection with this an experimental search for neutron - mirror neutron (nn') transitions has been carried out using storage of ultracold neutrons in a trap with different magnetic fields. As a result, a new limit for the neutron - mirror neutron oscillation time has been obtained, tau_osc >= 448 s (90% C.L.), assuming that there is no mirror magnetic field larger than 100 nT. Besides a first attempt to obtain some restriction for mirror magnetic field has been done.

preprint2009arXiv

UCN production by multiphonon processes in superfluid Helium under pressure

Cold neutrons are converted to ultra-cold neutrons (UCN) by the excitation of a single phonon or multiphonons in superfluid helium. The dynamic scattering function S(q, omega) of the superfluid helium strongly depends on pressure, leading to a pressure- dependent differential UCN production rate. A phenomenological expression for the multiphonon part of the scattering function s(lambda) describing UCN production has been derived from inelastic neutron scattering data. When combined with the production rate from single phonon processes this allows us to calculate the UCN production for any incident neutron flux. For calculations of the UCN production from single phonon processes we propose to use the values for S*(SVP) = 0.118(8) and S*(20 bar) = 0.066(6). As an example we will calculate the expected UCN production rate at the cold neutron beam for fundamental physics PF1b at the Institut Laue Langevin. We conclude that UCN production in superfluid helium under pressure is not attractive.

preprint2009arXiv

Ultracold-neutron infrastructure for the gravitational spectrometer GRANIT

The gravitational spectrometer GRANIT will be set up at the Institut Laue Langevin. It will profit from the high ultracold neutron density produced by a dedicated source. A monochromator made of crystals from graphite intercalated with potassium will provide a neutron beam with 0.89 nm incident on the source. The source employs superthermal conversion of cold neutrons in superfluid helium, in a vessel made from BeO ceramics with Be windows. A special extraction technique has been tested which feeds the spectrometer only with neutrons with a vertical velocity component v < 20 cm/s, thus keeping the density in the source high. This new source is expected to provide a density of up to 800 1/cm3 for the spectrometer.

preprint2008arXiv

Measuring the proton spectrum in neutron decay - latest results with aSPECT

The retardation spectrometer aSPECT was built to measure the shape of the proton spectrum in free neutron decay with high precision. This allows us to determine the antineutrino electron angular correlation coefficient a. We aim for a precision more than one order of magnitude better than the present best value, which is Delta_a /a = 5%. In a recent beam time performed at the Institut Laue-Langevin during April / May 2008 we reached a statistical accuracy of about 2% per 24 hours measurement time. Several systematic effects were investigated experimentally. We expect the total relative uncertainty to be well below 5%.

preprint2007arXiv

A clean, bright, and versatile source of neutron decay products

We present a case study on a new type of cold neutron beam station for the investigation of angular correlations in the beta-decay of free neutrons. With this beam station, called PERC, the 'active decay volume' lies inside the neutron guide, and the charged neutron decay products are magnetically guided towards the end of the neutron guide. Hence, the guide delivers at its exit a beam of decay electrons and protons, under well-defined and precisely variable conditions, which can be well separated from the cold neutron beam. In this way a general-purpose source of neutron decay products is obtained which can be used for various different experiments in neutron decay correlation spectroscopy. A gain in phase space density of several orders of magnitude can be achieved with PERC, as compared to existing neutron decay spectrometers. Neutron beam related background is separately measurable in PERC, and magnetic mirror effects on the charged neutron decay products and edge effects in the active neutron beam volume are both strongly suppressed. Therefore the spectra and angular distributions of the emerging decay particles will be distortion-free on the level of 10^-4, more than 10 times better than achieved today.