Researcher profile

Riccardo Ferrari

Riccardo Ferrari contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

A Switching Thrust Tracking Controller for Load Constrained Wind Turbines

Wind turbines are prone to structural degradation, particularly in offshore locations. Based on the structural health condition of the tower, power de-rating strategies can be used to reduce structural loads at the cost of power losses.This paper introduces a novel closed-loop switching control architecture to constrain the thrust in individual turbines. By taking inspiration from developments in the field of reference governors, an existing demanded power tracking controller is extended by a thrust tracking controller. The latter is activated only when a user-defined constraint on fore-aft thrust force is exceeded, which can be set based on the actual damage status of the turbine. Having a down-regulation with monotonic aerodynamic load response, a simple linear thrust tracking controller is proposed. Such a scheme can reduce aerodynamic loads while incurring acceptable losses on power production which, in a wind farm setting, can be compensated for by other turbines. Large eddy simulations demonstrate the performance of the proposed scheme on satisfying thrust constraints.

preprint2022arXiv

Active power control of wind farms: an instantaneous approach on waked conditions

This paper presents a closed-loop controller for wind farms to provide active power control services using a high-fidelity computational fluid dynamics based wind plant simulator. The proposed design enhances power tracking stability and allows for simple understanding, where each turbine is considered as a pure time-delay system. The paper investigates the control performance with different nominal power distributions in a fully waked condition and limited power availability. Results demonstrate the improvement in power production obtained by closing the control loop, compared to greedy operation. Additionally, power tracking capabilities are enhanced with a nominal power distribution favored by axial-induction, as well as the occurrence of turbine saturation and the distribution of loads.

preprint2022arXiv

Unbiased Active Inference for Classical Control

Active inference is a mathematical framework that originated in computational neuroscience. Recently, it has been demonstrated as a promising approach for constructing goal-driven behavior in robotics. Specifically, the active inference controller (AIC) has been successful on several continuous control and state-estimation tasks. Despite its relative success, some established design choices lead to a number of practical limitations for robot control. These include having a biased estimate of the state, and only an implicit model of control actions. In this paper, we highlight these limitations and propose an extended version of the unbiased active inference controller (u-AIC). The u-AIC maintains all the compelling benefits of the AIC and removes its limitations. Simulation results on a 2-DOF arm and experiments on a real 7-DOF manipulator show the improved performance of the u-AIC with respect to the standard AIC. The code can be found at https://github.com/cpezzato/unbiased_aic.

preprint2021arXiv

Towards Stochastic Fault-tolerant Control using Precision Learning and Active Inference

This work presents a fault-tolerant control scheme for sensory faults in robotic manipulators based on active inference. In the majority of existing schemes, a binary decision of whether a sensor is healthy (functional) or faulty is made based on measured data. The decision boundary is called a threshold and it is usually deterministic. Following a faulty decision, fault recovery is obtained by excluding the malfunctioning sensor. We propose a stochastic fault-tolerant scheme based on active inference and precision learning which does not require a priori threshold definitions to trigger fault recovery. Instead, the sensor precision, which represents its health status, is learned online in a model-free way allowing the system to gradually, and not abruptly exclude a failing unit. Experiments on a robotic manipulator show promising results and directions for future work are discussed.

preprint2020arXiv

Fault Diagnosis of the 10MW Floating Offshore Wind Turbine Benchmark: a Mixed Model and Signal-based Approach

Floating Offshore Wind Turbines (FOWTs) operate in the harsh marine environment with limited accessibility and maintainability. Not only failures are more likely to occur than in land-based turbines, but also corrective maintenance is more expensive. In the present study, a mixed model and signal-based Fault Diagnosis (FD) architecture is developed to detect and isolate critical faults in FOWTs. More specifically, a model-based scheme is developed to detect and isolate the faults associated with the turbine system. It is based on a fault detection and approximation estimator and fault isolation estimators, with time-varying adaptive thresholds to guarantee against false-alarms. In addition, a signal-based scheme is established, within the proposed architecture, for detecting and isolating two representative mooring lines faults. For the purpose of verification, a 10MW FOWT benchmark is developed and its operating conditions, which contains predefined faults, are simulated by extending the high-fidelity simulator. Based on it, the effectiveness of the proposed architecture is illustrated. In addition, the advantages and limitations are discussed by comparing its fault detection to the results delivered by other approaches. Results show that the proposed architecture has the best performance in detecting and isolating the critical faults in FOWTs under diverse operating conditions.