Researcher profile

Jan-Willem van Wingerden

Jan-Willem van Wingerden contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

A Switching Thrust Tracking Controller for Load Constrained Wind Turbines

Wind turbines are prone to structural degradation, particularly in offshore locations. Based on the structural health condition of the tower, power de-rating strategies can be used to reduce structural loads at the cost of power losses.This paper introduces a novel closed-loop switching control architecture to constrain the thrust in individual turbines. By taking inspiration from developments in the field of reference governors, an existing demanded power tracking controller is extended by a thrust tracking controller. The latter is activated only when a user-defined constraint on fore-aft thrust force is exceeded, which can be set based on the actual damage status of the turbine. Having a down-regulation with monotonic aerodynamic load response, a simple linear thrust tracking controller is proposed. Such a scheme can reduce aerodynamic loads while incurring acceptable losses on power production which, in a wind farm setting, can be compensated for by other turbines. Large eddy simulations demonstrate the performance of the proposed scheme on satisfying thrust constraints.

preprint2022arXiv

Active power control of wind farms: an instantaneous approach on waked conditions

This paper presents a closed-loop controller for wind farms to provide active power control services using a high-fidelity computational fluid dynamics based wind plant simulator. The proposed design enhances power tracking stability and allows for simple understanding, where each turbine is considered as a pure time-delay system. The paper investigates the control performance with different nominal power distributions in a fully waked condition and limited power availability. Results demonstrate the improvement in power production obtained by closing the control loop, compared to greedy operation. Additionally, power tracking capabilities are enhanced with a nominal power distribution favored by axial-induction, as well as the occurrence of turbine saturation and the distribution of loads.

preprint2022arXiv

Damping Identification of an Operational Offshore Wind Turbine using Kalman filter-based Subspace Identification

Operational Modal Analysis (OMA) provides essential insights into the structural dynamics of an Offshore Wind Turbine (OWT). In these dynamics, damping is considered an especially important parameter as it governs the magnitude of the response at the natural frequencies. Violation of the stationary white noise excitation requirement of classical OMA algorithms has troubled the identification of operational OWTs due to harmonic excitation caused by rotor rotation. Recently, a novel algorithm was presented that mitigates harmonics by estimating a harmonic subsignal using a Kalman filter and orthogonally removing this signal from the response signal, after which the Stochastic Subspace Identification algorithm is used to identify the system. In this paper, the algorithm is tested on field data obtained from a multi-megawatt operational OWT using an economical sensor setup with two accelerometer levels. The first three tower bending modes could be distinguished, and, through the LQ-decomposition used in the algorithm, the identification results could be improved further by concatenating multiple datasets. A comparison against established harmonics-mitigating algorithms, Modified Least-squared Complex Exponential and PolyMAX, was done to validate the results.

preprint2022arXiv

Data-enabled predictive control with instrumental variables: the direct equivalence with subspace predictive control

Direct data-driven control has attracted substantial interest since it enables optimization-based control without the need for a parametric model. This paper presents a new Instrumental Variable~(IV) approach to Data-enabled Predictive Control (DeePC) that results in favorable noise mitigation properties, and demonstrates the direct equivalence between DeePC and Subspace Predictive Control (SPC). The methodology relies on the derivation of the characteristic equation in DeePC along the lines of subspace identification algorithms. A particular choice of IVs is presented that is uncorrelated with future noise, but at the same time highly correlated with the data matrix. A simulation study demonstrates the improved performance of the proposed algorithm in the presence of process and measurement noise.

preprint2020arXiv

Fault Diagnosis of the 10MW Floating Offshore Wind Turbine Benchmark: a Mixed Model and Signal-based Approach

Floating Offshore Wind Turbines (FOWTs) operate in the harsh marine environment with limited accessibility and maintainability. Not only failures are more likely to occur than in land-based turbines, but also corrective maintenance is more expensive. In the present study, a mixed model and signal-based Fault Diagnosis (FD) architecture is developed to detect and isolate critical faults in FOWTs. More specifically, a model-based scheme is developed to detect and isolate the faults associated with the turbine system. It is based on a fault detection and approximation estimator and fault isolation estimators, with time-varying adaptive thresholds to guarantee against false-alarms. In addition, a signal-based scheme is established, within the proposed architecture, for detecting and isolating two representative mooring lines faults. For the purpose of verification, a 10MW FOWT benchmark is developed and its operating conditions, which contains predefined faults, are simulated by extending the high-fidelity simulator. Based on it, the effectiveness of the proposed architecture is illustrated. In addition, the advantages and limitations are discussed by comparing its fault detection to the results delivered by other approaches. Results show that the proposed architecture has the best performance in detecting and isolating the critical faults in FOWTs under diverse operating conditions.

preprint2020arXiv

Preventing wind turbine tower natural frequency excitation with a quasi-LPV model predictive control scheme

With the ever increasing power rates of wind turbines, more advanced control techniques are needed to facilitate tall towers that are low-weight and cost effective, but in effect more flexible. Such soft-soft tower configurations generally have their fundamental side-side frequency in the below-rated operational domain. Because the turbine rotor practically has or develops a mass imbalance over time, a periodic and rotor-speed dependent side-side excitation is present during below-rated operation. Persistent operation at the coinciding tower and rotational frequency degrades the expected structural life span. To reduce this effect, earlier work has shown the effectiveness of active tower damping control strategies using collective pitch control. A more passive approach is frequency skipping by inclusion of speed exclusion zones, which avoids prolonged operation near the critical frequency. However, neither of the methods incorporate a convenient way of performing a trade-off between energy maximization and fatigue load minimization. Therefore, this paper introduces a quasi-linear parameter varying model predictive control (qLPV-MPC) scheme, exploiting the beneficial (convex) properties of a qLPV system description. The qLPV model is obtained by a demodulation transformation, and is subsequently augmented with a simple wind turbine model. Results show the effectiveness of the algorithm in synthetic and realistic simulations using the NREL 5-MW reference wind turbine in high-fidelity simulation code. Prolonged rotor speed operation at the tower side-side natural frequency is prevented, whereas when the trade-off is in favor of energy production, the algorithm decides to rapidly pass over the natural frequency to attain higher rotor speeds and power productions.

preprint2020arXiv

The helix approach: using dynamic individual pitch control to enhance wake mixing in wind farms

Wind farm control using dynamic concepts is a research topic that is receiving an increasing amount of interest. The main concept of this approach is that dynamic variations of the wind turbine control settings lead to higher wake turbulence, and subsequently faster wake recovery due to increased mixing. As a result, downstream turbines experience higher wind speeds, thus increasing their energy capture. The current state of the art in dynamic wind farm control is to vary the magnitude of the thrust force of an upstream turbine. Although very effective, this approach also leads to increased power and thrust variations, negatively impacting energy quality and fatigue loading. In this paper, a novel approach for the dynamic control of wind turbines in a wind farm is proposed: using individual pitch control, the fixed-frame tilt and yaw moments on the turbine are varied, thus dynamically manipulating the wake. This strategy is named the helix approach since the resulting wake has a helical shape. Large eddy simulations of a two-turbine wind farm show that the helix approach leads to enhanced wake mixing with minimal power and thrust variations.