Source author record

R. Zboray

R. Zboray appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2015arXiv

High-frame rate, fast neutron imaging of two-phase flow in a thin rectangular channel

We have demonstrated the feasibility of performing high-frame-rate, fast neutron radiography of air-water two-phase flows in a thin channel with rectangular cross section. The experiments have been carried out at the accelerator facility of the Physikalisch-Technische Bundesanstalt. A polychromatic, high-intensity fast neutron beam with average energy of 6 MeV was produced by 11.5 MeV deuterons hitting a thick Be target. Image sequences down to 10 millisecond exposure times were obtained using a fast-neutron imaging detector developed in the context of fast-neutron resonance imaging. Different two-phase flow regimes such as bubbly slug and churn flows have been examined. Two phase flow parameters like the volumetric gas fraction, bubble size and bubble velocities have been measured. The first results are promising, improvements for future experiments are also discussed.

preprint2012arXiv

Concept of a novel fast neutron imaging detector based on THGEM for fan-beam tomography applications

The conceptual design and operational principle of a novel high-efficiency, fast neutron imaging detector based on THGEM, intended for future fan-beam transmission tomography applications, is described. We report on a feasibility study based on theoretical modeling and computer simulations of a possible detector configuration prototype. In particular we discuss results regarding the optimization of detector geometry, estimation of its general performance, and expected imaging quality: it has been estimated that detection efficiency of around 5-8% can be achieved for 2.5MeV neutrons; spatial resolution is around one millimeter with no substantial degradation due to scattering effects. The foreseen applications of the imaging system are neutron tomography in non-destructive testing for the nuclear energy industry, including examination of spent nuclear fuel bundles, detection of explosives or drugs, as well as investigation of thermal hydraulics phenomena (e.g., two-phase flow, heat transfer, phase change, coolant dynamics, and liquid metal flow).

preprint2012arXiv

First studies of electron transport along small gas gaps of novel foil radiation converters for fast-neutron detectors

Novel high efficiency fast-neutron detectors were suggested for fan-beam tomography applications. They combine multi-layer polymer converters in gas medium, coupled to thick gaseous electron multipliers (THGEM). In this work we discuss the results of a systematic study of the electron transport inside a narrow gap between successive converter foils, which affects the performance of the detector, both in terms of detection efficiency and localization properties. The efficiency of transporting ionization electrons was measured along a 0.6 mm wide gas gap in 6 and 10 mm wide polymer converters Computer simulations provided conceptual understanding of the observations. For a drift lengths of 6 mm electrons were efficiently transported along the narrow gas gap, with minimal diffusion-induced losses; an average collection efficiency of 95% was achieved for the ionization electrons induced by a primary electron of a few keV initial energy. The 10 mm height converter yielded considerably lower efficiency due to electrical and mechanical flaws of the converter foils. The results indicate that detection efficiencies of around 7% can be expected for 2.5 MeV neutrons with 300 foils converters, of 6 mm height, 0.4 mm thick foils and 0.6 mm gas gap.