Source author record

V. Dangendorf

V. Dangendorf appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

14works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

14 published item(s)

preprint2016arXiv

Quantitative discrimination between oil and water in drilled bore cores via fast-neutron resonance transmission radiography

A novel method based on Fast Neutron Resonance Transmission Radiography is proposed for non-destructive, quantitative determination of the weight percentages of oil and water in cores taken from subterranean or underwater geological formations. The ability of the method to distinguish water from oil stems from the unambiguously-specific energy dependence of the neutron cross-sections for the principal elemental constituents. Monte-Carlo simulations and initial results of experimental investigations indicate that the technique may provide a rapid, accurate and non-destructive method for quantitative evaluation of core fluids in thick intact cores, including those of tight shales for which the use of conventional core analytical approaches appears to be questionable.

preprint2015arXiv

High-frame rate, fast neutron imaging of two-phase flow in a thin rectangular channel

We have demonstrated the feasibility of performing high-frame-rate, fast neutron radiography of air-water two-phase flows in a thin channel with rectangular cross section. The experiments have been carried out at the accelerator facility of the Physikalisch-Technische Bundesanstalt. A polychromatic, high-intensity fast neutron beam with average energy of 6 MeV was produced by 11.5 MeV deuterons hitting a thick Be target. Image sequences down to 10 millisecond exposure times were obtained using a fast-neutron imaging detector developed in the context of fast-neutron resonance imaging. Different two-phase flow regimes such as bubbly slug and churn flows have been examined. Two phase flow parameters like the volumetric gas fraction, bubble size and bubble velocities have been measured. The first results are promising, improvements for future experiments are also discussed.

preprint2015arXiv

Time-resolved neutron imaging at ANTARES cold neutron beamline

In non-destructive evaluation with X-rays light elements embedded in dense, heavy (or high-Z) matrices show little contrast and their structural details can hardly be revealed. Neutron radiography, on the other hand, provides a solution for those cases, in particular for hydrogenous materials, owing to the large neutron scattering cross section of hydrogen and uncorrelated dependency of neutron cross section on the atomic number. The majority of neutron imaging experiments at the present time is conducted with static objects mainly due to the limited flux intensity of neutron beamline facilities and sometimes due to the limitations of the detectors. However, some applications require the studies of dynamic phenomena and can now be conducted at several high intensity beamlines such as the recently rebuilt ANTARES beam line at the FRM-II reactor. In this paper we demonstrate the capabilities of time resolved imaging for repetitive processes, where different phases of the process can be imaged simultaneously and integrated over multiple cycles. A fast MCP/Timepix neutron counting detector was used to image the water distribution within a model steam engine operating at 10 Hz frequency. Within <10 minutes integration the amount of water was measured as a function of cycle time with a sub-mm spatial resolution, thereby demonstrating the capabilities of time-resolved neutron radiography for the future applications. The neutron spectrum of the ANTARES beamline as well as transmission spectra of a Fe sample were also measured with the Time Of Flight (TOF) technique in combination with a high resolution beam chopper. The energy resolution of our setup was found to be ~0.8% at 5 meV and ~1.7% at 25 meV.

preprint2013arXiv

Parameters Affecting Temporal Resolution of Time Resolved Integrative Optical Neutron Detector (TRION)

The Time-Resolved Integrative Optical Neutron (TRION) detector was developed for Fast Neutron Resonance Radiography (FNRR), a fast-neutron transmission imaging method that exploits characteristic energy-variations of the total scattering cross-section in the En = 1-10 MeV range to detect specific elements within a radiographed object. As opposed to classical event-counting time of flight (ECTOF), it integrates the detector signal during a well-defined neutron Time of Flight window corresponding to a pre-selected energy bin, e.g., the energy-interval spanning a cross-section resonance of an element such as C, O and N. The integrative characteristic of the detector permits loss-free operation at very intense, pulsed neutron fluxes, at a cost however, of recorded temporal resolution degradation. This work presents a theoretical and experimental evaluation of detector related parameters which affect temporal resolution of the TRION system.

preprint2013arXiv

Unambiguous Identification of the Second 2+ State in 12C and the Structure of the Hoyle State

The second 2+ state of 12C, predicted over fifty years ago as an excitation of the Hoyle state, has been unambiguously identified using the 12C(g,a_0)8Be reaction. The alpha particles produced by the photodisintegration of 12C were detected using an Optical Time Projection Chamber (O-TPC). Data were collected at beam energies between 9.1 and 10.7 MeV using the intense nearly mono-energetic gamma-ray beams at the HIgS facility. The measured angular distributions determine the cross section and the E1-E2 relative phases as a function of energy leading to an unambiguous identification of the second 2+ state in 12C at 10.03(11) MeV, with a total width of 800(130) keV and a ground state gamma-decay width of 60(10) meV; B(E2: 2+ ---> gs) = 0.73(13) e2fm4 [or 0.45(8) W.u.]. The Hoyle state and its rotational 2+ state that are more extended than the ground state of 12C presents a challenge and constraints for models attempting to reveal the nature of three alpha particle states in 12C. Specifically it challenges the ab-initio Lattice Effective Field Theory (L-EFT) calculations that predict similar r.m.s. radii for the ground state and the Hoyle state.

preprint2012arXiv

Concept of a novel fast neutron imaging detector based on THGEM for fan-beam tomography applications

The conceptual design and operational principle of a novel high-efficiency, fast neutron imaging detector based on THGEM, intended for future fan-beam transmission tomography applications, is described. We report on a feasibility study based on theoretical modeling and computer simulations of a possible detector configuration prototype. In particular we discuss results regarding the optimization of detector geometry, estimation of its general performance, and expected imaging quality: it has been estimated that detection efficiency of around 5-8% can be achieved for 2.5MeV neutrons; spatial resolution is around one millimeter with no substantial degradation due to scattering effects. The foreseen applications of the imaging system are neutron tomography in non-destructive testing for the nuclear energy industry, including examination of spent nuclear fuel bundles, detection of explosives or drugs, as well as investigation of thermal hydraulics phenomena (e.g., two-phase flow, heat transfer, phase change, coolant dynamics, and liquid metal flow).

preprint2012arXiv

First studies of electron transport along small gas gaps of novel foil radiation converters for fast-neutron detectors

Novel high efficiency fast-neutron detectors were suggested for fan-beam tomography applications. They combine multi-layer polymer converters in gas medium, coupled to thick gaseous electron multipliers (THGEM). In this work we discuss the results of a systematic study of the electron transport inside a narrow gap between successive converter foils, which affects the performance of the detector, both in terms of detection efficiency and localization properties. The efficiency of transporting ionization electrons was measured along a 0.6 mm wide gas gap in 6 and 10 mm wide polymer converters Computer simulations provided conceptual understanding of the observations. For a drift lengths of 6 mm electrons were efficiently transported along the narrow gas gap, with minimal diffusion-induced losses; an average collection efficiency of 95% was achieved for the ionization electrons induced by a primary electron of a few keV initial energy. The 10 mm height converter yielded considerably lower efficiency due to electrical and mechanical flaws of the converter foils. The results indicate that detection efficiencies of around 7% can be expected for 2.5 MeV neutrons with 300 foils converters, of 6 mm height, 0.4 mm thick foils and 0.6 mm gas gap.

preprint2012arXiv

Monte-Carlo Simulations of Radiation-Induced Activation in a Fast-Neutron and Gamma- Based Cargo Inspection System

An air cargo inspection system combining two nuclear reaction based techniques, namely Fast-Neutron Resonance Radiography and Dual-Discrete-Energy Gamma Radiography is currently being developed. This system is expected to allow detection of standard and improvised explosives as well as special nuclear materials. An important aspect for the applicability of nuclear techniques in an airport inspection facility is the inventory and lifetimes of radioactive isotopes produced by the neutron and gamma radiation inside the cargo, as well as the dose delivered by these isotopes to people in contact with the cargo during and following the interrogation procedure. Using MCNPX and CINDER90 we have calculated the activation levels for several typical inspection scenarios. One example is the activation of various metal samples embedded in a cotton-filled container. To validate the simulation results, a benchmark experiment was performed, in which metal samples were activated by fast-neutrons in a water-filled glass jar. The induced activity was determined by analyzing the gamma spectra. Based on the calculated radioactive inventory in the container, the dose levels due to the induced gamma radiation were calculated at several distances from the container and in relevant time windows after the irradiation, in order to evaluate the radiation exposure of the cargo handling staff, air crew and passengers during flight. The possibility of remanent long-lived radioactive inventory after cargo is delivered to the client is also of concern and was evaluated.

preprint2011arXiv

An Optical Readout TPC (O-TPC) for Studies in Nuclear Astrophysics With Gamma-Ray Beams at HIgS

We report on the construction, tests, calibrations and commissioning of an Optical Readout Time Projection Chamber (O-TPC) detector operating with a CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure the cross sections of several key nuclear reactions involved in stellar evolution. In particular, a study of the rate of formation of oxygen and carbon during the process of helium burning will be performed by exposing the chamber gas to intense nearly mono-energetic gamma-ray beams at the High Intensity Gamma Source (HIgS) facility. The O-TPC has a sensitive target-drift volume of 30x30x21 cm^3. Ionization electrons drift towards a double parallel grid avalanche multiplier, yielding charge multiplication and light emission. Avalanche induced photons from N2 emission are collected, intensified and recorded with a Charge Coupled Device (CCD) camera, providing two-dimensional track images. The event's time projection (third coordinate) and the deposited energy are recorded by photomultipliers and by the TPC charge-signal, respectively. A dedicated VME-based data acquisition system and associated data analysis tools were developed to record and analyze these data. The O-TPC has been tested and calibrated with 3.183 MeV alpha-particles emitted by a 148Gd source placed within its volume with a measured energy resolution of 3.0%. Tracks of alpha and 12C particles from the dissociation of 16O and of three alpha-particles from the dissociation of 12C have been measured during initial in-beam test experiments performed at the HIgS facility at Duke University. The full detection system and its performance are described and the results of the preliminary in-beam test experiments are reported.

preprint2011arXiv

Proof of principle of a high-spatial-resolution, resonant-response gamma-ray detector for Gamma Resonance Absorption in 14N

The development of a mm-spatial-resolution, resonant-response detector based on a micrometric glass capillary array filled with liquid scintillator is described. This detector was developed for Gamma Resonance Absorption (GRA) in 14N. GRA is an automatic-decision radiographic screening technique that combines high radiation penetration (the probe is a 9.17 MeV gamma ray) with very good sensitivity and specificity to nitrogenous explosives. Detailed simulation of the detector response to electrons and protons generated by the 9.17 MeV gamma-rays was followed by a proof-of-principle experiment, using a mixed gamma-ray and neutron source. Towards this, a prototype capillary detector was assembled, including the associated filling and readout systems. Simulations and experimental results indeed show that proton tracks are distinguishable from electron tracks at relevant energies, on the basis of a criterion that combines track length and light intensity per unit length.

preprint2010arXiv

A Dual-Purpose Ion-Accelerator for Nuclear-Reaction-Based Explosives-and SNM-Detection in Massive Cargo

A dual-purpose ion-accelerator concept, capable of serving as radiation source in a versatile, nuclear-reaction-based cargo inspection system, is presented. The system will automatically and reliably detect small, operationally-relevant quantities of concealed explosives and special nuclear materials (SNM). It will be cost-effective, employing largely-common hardware, but different reactions/DAQ-modes. Typical expected throughput is 10-20 aviation containers/hr. PACS: 25.20.Dc; 25.40.Ny; 27.20.+n; 29.27.Fh; 79.77.+g; 89.20.Bb; 89.20.Dd Keywords: Cargo inspection; Nuclear-reaction-based methods; Explosives detection; SNM detection

preprint2010arXiv

Development of an LED reference light source for calibration of radiographic imaging detectors

A stable reference light source based on an LED (Light Emission Diode) is presented for stabilizing the conversion gain of the opto-electronic system of a gamma- and fast-neutron radiographic and tomographic imaging device. A constant fraction of the LED light is transported to the image plane of the camera and provides a stable reference exposure. This is used to normalize the images during off-line image processing. We have investigated parameters influencing the stability of LEDs and developed procedures and criteria to prepare and select LEDs suitable for delivering stable light outputs for several 100 h of operation.

preprint2004arXiv

Detectors for Energy-Resolved Fast Neutron Imaging

Two detectors for energy-resolved fast-neutron imaging in pulsed broad-energy neutron beams are presented. The first one is a neutron-counting detector based on a solid neutron converter coupled to a gaseous electron multiplier (GEM). The second is an integrating imaging technique, based on a scintillator for neutron conversion and an optical imaging system with fast framing capability.

preprint2003arXiv

High Resolution Heavy Ion Track Structure Imaging

The difference in the relative biological efficincy (RBE) of ions of same linear energy transfer (LET) but different atomic number (Z) can be attributed to the difference in the radial ionisation distribution. In this contribution we present data from measurements of the spatial ionisation pattern of heavy ions of various Z but similar LET and compare the results with track structure data obtained by Monte Carlo simulations. The measurements were made with a time projection chamber with optical readout (Optical Avalanche Chamber, OPAC) which is able to quantitatively capture the spatial ionisation pattern of an ion traversing the chamber