Source author record

H. -M. Prasser

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
1topics
4close collaborators

Published work

2 publications

preprint2012arXiv

Concept of a novel fast neutron imaging detector based on THGEM for fan-beam tomography applications

The conceptual design and operational principle of a novel high-efficiency, fast neutron imaging detector based on THGEM, intended for future fan-beam transmission tomography applications, is described. We report on a feasibility study based on theoretical modeling and computer simulations of a possible detector configuration prototype. In particular we discuss results regarding the optimization of detector geometry, estimation of its general performance, and expected imaging quality: it has been estimated that detection efficiency of around 5-8% can be achieved for 2.5MeV neutrons; spatial resolution is around one millimeter with no substantial degradation due to scattering effects. The foreseen applications of the imaging system are neutron tomography in non-destructive testing for the nuclear energy industry, including examination of spent nuclear fuel bundles, detection of explosives or drugs, as well as investigation of thermal hydraulics phenomena (e.g., two-phase flow, heat transfer, phase change, coolant dynamics, and liquid metal flow).

preprint2012arXiv

First studies of electron transport along small gas gaps of novel foil radiation converters for fast-neutron detectors

Novel high efficiency fast-neutron detectors were suggested for fan-beam tomography applications. They combine multi-layer polymer converters in gas medium, coupled to thick gaseous electron multipliers (THGEM). In this work we discuss the results of a systematic study of the electron transport inside a narrow gap between successive converter foils, which affects the performance of the detector, both in terms of detection efficiency and localization properties. The efficiency of transporting ionization electrons was measured along a 0.6 mm wide gas gap in 6 and 10 mm wide polymer converters Computer simulations provided conceptual understanding of the observations. For a drift lengths of 6 mm electrons were efficiently transported along the narrow gas gap, with minimal diffusion-induced losses; an average collection efficiency of 95% was achieved for the ionization electrons induced by a primary electron of a few keV initial energy. The 10 mm height converter yielded considerably lower efficiency due to electrical and mechanical flaws of the converter foils. The results indicate that detection efficiencies of around 7% can be expected for 2.5 MeV neutrons with 300 foils converters, of 6 mm height, 0.4 mm thick foils and 0.6 mm gas gap.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.