Source author record

R. P. Anderson

R. P. Anderson appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

10works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2019arXiv

Realization of a fractional period adiabatic superlattice

We propose and realize a deeply sub-wavelength optical lattice for ultracold neutral atoms using $N$ resonantly Raman-coupled internal degrees of freedom. Although counter-propagating lasers with wavelength $λ$ provided two-photon Raman coupling, the resultant lattice-period was $λ/2N$, an $N$-fold reduction as compared to the conventional $λ/2$ lattice period. We experimentally demonstrated this lattice built from the three $F=1$ Zeeman states of a $^{87}{\rm Rb}$ Bose-Einstein condensate, and generated a lattice with a $λ/6= 132\ {\rm nm}$ period from $λ=790 \ {\rm nm}$ lasers. Lastly, we show that adding an additional RF coupling field converts this lattice into a superlattice with $N$ wells uniformly spaced within the original $λ/2$ unit cell.

preprint2016arXiv

Measurement and extinction of vector light shifts using interferometry of spinor condensates

We use differential Ramsey interferometry of ultracold atoms to characterize the vector light shift (VLS) from a far-off resonance optical dipole trap at $λ= 1064\,\mathrm{nm}$. The VLS manifests as a `fictitious' magnetic field, which we perceive as a change in the Larmor frequency of two spinor condensates exposed to different intensities of elliptically polarized light. We use our measurement scheme to diagnose the light-induced magnetic field and suppress it to $2.1(8)\times10^{-4}$ of its maximum value, by making the trapping light linearly polarized with a quarter-wave plate in each beam. Our sensitive measurement of the VLS-induced field demonstrates high-precision, in-vacuo interferometric polarimetry of dipole trapping light and can be adapted to measure vector shifts from other lasers, advancing the application of optically trapped atoms to precision metrology.

preprint2015arXiv

A Monte Carlo wavefunction method for semiclassical simulations of spin-position entanglement

We present a Monte Carlo wavefunction method for semiclassically modeling spin-$\frac12$ systems in a magnetic field gradient in one dimension. Our model resolves the conflict of determining what classical force an atom should be subjected to when it is in an arbitrary superposition of internal states. Spatial degrees of freedom are considered to be an environment, entanglement with which decoheres the internal states. Atoms follow classical trajectories through space, punctuated by probabilistic jumps between spin states. We modify the conventional Monte Carlo wavefunction method to jump between states when population transfer occurs, rather than when population is later discarded via exponential decay. This results in a spinor wavefunction that is continuous in time, and allows us to model the classical particle trajectories (evolution of the environment variables) more accurately. The model is not computationally demanding and it agrees well with simulations of the full spatial wavefunction of an atom.

preprint2015arXiv

Magnetic tensor gradiometry using Ramsey interferometry of spinor condensates

We have realized a magnetic tensor gradiometer by interferometrically measuring the relative phase between two spatially separated Bose-Einstein condensates (BECs). We perform simultaneous Ramsey interferometry of the proximate $^{87}$Rb spin-1 condensates in freefall and infer their relative Larmor phase -- and thus the differential magnetic field strength -- with a common-mode phase noise suppression exceeding $50\,\mathrm{dB}$. By appropriately biasing the magnetic field and separating the BECs along orthogonal directions, we measure the magnetic field gradient tensor of ambient and applied magnetic fields with a nominal precision of $30\,\mathrm{μG\,cm^{-1}}$ and a sensor volume of $2\times10^{-5}\,\mathrm{mm}^3$. We predict a spin-projection noise limited magnetic energy resolution of order $\hbar$ for typical Zeeman coherence times of trapped condensates with this scheme, even with the low measurement duty cycle inherent to BEC experiments.

preprint2014arXiv

Self-induced Spatial Dynamics to Enhance Spin-Squeezing via One-Axis Twisting in a Two-Component Bose-Einstein Condensate

We theoretically investigate a scheme to enhance spin squeezing in a two-component Bose-Einstein condensate (BEC) by utilizing the inherent mean-field dynamics of the condensate. Due to the asymmetry in the scattering lengths, the two components exhibit density oscillations where they spatially separate and recombine. The effective non-linearity responsible for spin squeezing is increased by up to three orders of magnitude when the two components spatially separate \cite{treutlein2010}. We perform a multi-mode simulation of the system using the truncated Wigner method, and show that this method can be used to create significant spin squeezing in systems where the effective nonlinearity would ordinarily be too small, and that strong spatial dynamics resulting from large particle numbers aren't necessarily detrimental to generating spin-squeezing. We develop a simplified semi-analytic model that gives good agreement with our multi-mode simulation, and will be useful for predicting spin-squeezing in a range of different systems.

preprint2013arXiv

A scripted control system for autonomous hardware timed experiments

We present the labscript suite, an open-source experiment control system for automating shot-based experiments and their analysis. Experiments are composed as Python code, which is used to produce low-level hardware instructions. They are queued up and executed on the hardware in real time, synchronized by a pseudoclock. Experiment parameters are manipulated graphically, and analysis routines are run as new data is acquired. With this system, we can easily automate exploration of parameter spaces, including closed-loop optimization.

preprint2013arXiv

A versatile high resolution objective for imaging quantum gases

We present a high resolution objective lens made entirely from catalog singlets that has a numerical aperture of 0.36. It corrects for aberrations introduced by a glass window and has a long working distance of 35mm, making it suitable for imaging objects within a vacuum system. This offers simple high resolution imaging for many in the quantum gas community. The objective achieves a resolution of 1.3μm at the design wavelength of 780nm, and a diffraction-limited field of view of 360μm when imaging through a 5mm window. Images of a resolution target and a pinhole show quantitative agreement with the simulated lens performance. The objective is suitable for diffraction-limited imaging on the D2 line of all the alkalis by changing only the aperture diameter, retaining numerical apertures above 0.32. The design corrects for window thicknesses of up to 15mm if the singlet spacings are modified.

preprint2012arXiv

Precision atomic gravimeter based on Bragg diffraction

We present a precision gravimeter based on coherent Bragg diffraction of freely falling cold atoms. Traditionally, atomic gravimeters have used stimulated Raman transitions to separate clouds in momentum space by driving transitions between two internal atomic states. Bragg interferometers utilize only a single internal state, and can therefore be less susceptible to environmental perturbations. Here we show that atoms extracted from a magneto-optical trap using an accelerating optical lattice are a suitable source for a Bragg atom interferometer, allowing efficient beamsplitting and subsequent separation of momentum states for detection. Despite the inherently multi-state nature of atom diffraction, we are able to build a Mach-Zehnder interferometer using Bragg scattering which achieves a sensitivity to the gravitational acceleration of $Δg/g = 2.7\times10^{-9}$ with an integration time of 1000s. The device can also be converted to a gravity gradiometer by a simple modification of the light pulse sequence.

preprint2011arXiv

Cold atom gravimetry with a Bose-Einstein Condensate

We present a cold atom gravimeter operating with a sample of Bose-condensed Rubidium-87 atoms. Using a Mach-Zehnder configuration with the two arms separated by a two-photon Bragg transition, we observe interference fringes with a visibility of 83% at T=3 ms. We exploit large momentum transfer (LMT) beam splitting to increase the enclosed space-time area of the interferometer using higher-order Bragg transitions and Bloch oscillations. We also compare fringes from condensed and thermal sources, and observe a reduced visibility of 58% for the thermal source. We suspect the loss in visibility is caused partly by wavefront aberrations, to which the thermal source is more susceptible due to its larger transverse momentum spread. Finally, we discuss briefly the potential advantages of using a coherent atomic source for LMT, and present a simple mean-field model to demonstrate that with currently available experimental parameters, interaction-induced dephasing will not limit the sensitivity of inertial measurements using freely-falling, coherent atomic sources.

preprint2011arXiv

Optically trapped atom interferometry using the clock transition of large Rb-87 Bose-Einstein condensates

We present a Ramsey-type atom interferometer operating with an optically trapped sample of 10^6 Bose-condensed Rb-87 atoms. The optical trap allows us to couple the |F =1, mF =0>\rightarrow |F =2, mF =0> clock states using a single photon 6.8GHz microwave transition, while state selective readout is achieved with absorption imaging. Interference fringes with contrast approaching 100% are observed for short evolution times. We analyse the process of absorption imaging and show that it is possible to observe atom number variance directly, with a signal-to-noise ratio ten times better than the atomic projection noise limit on 10^6 condensate atoms. We discuss the technical and fundamental noise sources that limit our current system, and outline the improvements that can be made. Our results indicate that, with further experimental refinements, it will be possible to produce and measure the output of a sub-shot-noise limited, large atom number BEC-based interferometer. In an addendum to the original paper, we attribute our inability to observe quantum projection noise to the stability of our microwave oscillator and background magnetic field. Numerical simulations of the Gross-Pitaevskii equations for our system show that dephasing due to spatial dynamics driven by interparticle interactions account for much of the observed decay in fringe visibility at long interrogation times. The simulations show good agreement with the experimental data when additional technical decoherence is accounted for, and suggest that the clock states are indeed immiscible. With smaller samples of 5 \times 10^4 atoms, we observe a coherence time of τ = (1.0+0.5-0.3) s.