Source author record

J. D. Close

J. D. Close appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

14works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

14 published item(s)

preprint2014arXiv

A Bose-condensed, simultaneous dual species Mach-Zehnder atom interferometer

This paper presents the first realisation of a simultaneous $^{87}$Rb -$^{85}$Rb Mach-Zehnder atom interferometer with Bose-condensed atoms. A number of ambitious proposals for precise terrestrial and space based tests of the Weak Equivalence Principle rely on such a system. This implementation utilises hybrid magnetic-optical trapping to produce spatially overlapped condensates with a duty cycle of 20s. A horizontal optical waveguide with co-linear Bragg beamsplitters and mirrors is used to simultaneously address both isotopes in the interferometer. We observe a non-linear phase shift on a non-interacting $^{85}$Rb interferometer as a function of interferometer time, $T$, which we show arises from inter-isotope scattering with the co-incident $^{87}$Rb interferometer. A discussion of implications for future experiments is given.

preprint2012arXiv

11 W narrow linewidth laser source at 780nm for laser cooling and manipulation of Rubidium

We present a narrow linewidth continuous laser source with over 11 Watts of output power at 780nm, based on single-pass frequency doubling of an amplified 1560nm fibre laser with 36% efficiency. This source offers a combination of high power, simplicity, mode quality and stability. Without any active stabilization, the linewidth is measured to be below 10kHz. The fibre seed is tunable over 60GHz, which allows access to the D2 transitions in 87Rb and 85Rb, providing a viable high-power source for laser cooling as well as for large-momentum-transfer beamsplitters in atom interferometry. Sources of this type will pave the way for a new generation of high flux, high duty-cycle degenerate quantum gas experiments.

preprint2012arXiv

Atom lasers: production, properties and prospects for precision inertial measurement

We review experimental progress on atom lasers out-coupled from Bose-Einstein condensates, and consider the properties of such beams in the context of precision inertial sensing. The atom laser is the matter-wave analog of the optical laser. Both devices rely on Bose-enhanced scattering to produce a macroscopically populated trapped mode that is output-coupled to produce an intense beam. In both cases, the beams often display highly desirable properties such as low divergence, high spectral flux and a simple spatial mode that make them useful in practical applications, as well as the potential to perform measurements at or below the quantum projection noise limit. Both devices display similar second-order correlations that differ from thermal sources. Because of these properties, atom lasers are a promising source for application to precision inertial measurements.

preprint2012arXiv

Optically guided linear Mach Zehnder atom interferometer

We demonstrate a horizontal, linearly guided Mach Zehnder atom interferometer in an optical waveguide. Intended as a proof-of-principle experiment, the interferometer utilises a Bose-Einstein condensate in the magnetically insensitive |F=1,mF=0> state of Rubidium-87 as an acceleration sensitive test mass. We achieve a modest sensitivity to acceleration of da = 7x10^-4 m/s^2. Our fringe visibility is as high as 38% in this optically guided atom interferometer. We observe a time-of-flight in the waveguide of over half a second, demonstrating the utility of our optical guide for future sensors.

preprint2012arXiv

Precision atomic gravimeter based on Bragg diffraction

We present a precision gravimeter based on coherent Bragg diffraction of freely falling cold atoms. Traditionally, atomic gravimeters have used stimulated Raman transitions to separate clouds in momentum space by driving transitions between two internal atomic states. Bragg interferometers utilize only a single internal state, and can therefore be less susceptible to environmental perturbations. Here we show that atoms extracted from a magneto-optical trap using an accelerating optical lattice are a suitable source for a Bragg atom interferometer, allowing efficient beamsplitting and subsequent separation of momentum states for detection. Despite the inherently multi-state nature of atom diffraction, we are able to build a Mach-Zehnder interferometer using Bragg scattering which achieves a sensitivity to the gravitational acceleration of $Δg/g = 2.7\times10^{-9}$ with an integration time of 1000s. The device can also be converted to a gravity gradiometer by a simple modification of the light pulse sequence.

preprint2011arXiv

Bosenova and three-body loss in a Rb-85 Bose-Einstein condensate

Collapsing Bose-Einstein condensates are rich and complex quantum systems for which quantitative explanation by simple models has proved elusive. We present new experimental data on the collapse of high density Rb-85 condensates with attractive interactions and find quantitative agreement with the predictions of the Gross-Pitaevskii equation. The collapse data and measurements of the decay of atoms from our condensates allow us to put new limits on the value of the Rb-85 three-body loss coefficient K_3 at small positive and negative scattering lengths.

preprint2011arXiv

Cold atom gravimetry with a Bose-Einstein Condensate

We present a cold atom gravimeter operating with a sample of Bose-condensed Rubidium-87 atoms. Using a Mach-Zehnder configuration with the two arms separated by a two-photon Bragg transition, we observe interference fringes with a visibility of 83% at T=3 ms. We exploit large momentum transfer (LMT) beam splitting to increase the enclosed space-time area of the interferometer using higher-order Bragg transitions and Bloch oscillations. We also compare fringes from condensed and thermal sources, and observe a reduced visibility of 58% for the thermal source. We suspect the loss in visibility is caused partly by wavefront aberrations, to which the thermal source is more susceptible due to its larger transverse momentum spread. Finally, we discuss briefly the potential advantages of using a coherent atomic source for LMT, and present a simple mean-field model to demonstrate that with currently available experimental parameters, interaction-induced dephasing will not limit the sensitivity of inertial measurements using freely-falling, coherent atomic sources.

preprint2011arXiv

Optically trapped atom interferometry using the clock transition of large Rb-87 Bose-Einstein condensates

We present a Ramsey-type atom interferometer operating with an optically trapped sample of 10^6 Bose-condensed Rb-87 atoms. The optical trap allows us to couple the |F =1, mF =0>\rightarrow |F =2, mF =0> clock states using a single photon 6.8GHz microwave transition, while state selective readout is achieved with absorption imaging. Interference fringes with contrast approaching 100% are observed for short evolution times. We analyse the process of absorption imaging and show that it is possible to observe atom number variance directly, with a signal-to-noise ratio ten times better than the atomic projection noise limit on 10^6 condensate atoms. We discuss the technical and fundamental noise sources that limit our current system, and outline the improvements that can be made. Our results indicate that, with further experimental refinements, it will be possible to produce and measure the output of a sub-shot-noise limited, large atom number BEC-based interferometer. In an addendum to the original paper, we attribute our inability to observe quantum projection noise to the stability of our microwave oscillator and background magnetic field. Numerical simulations of the Gross-Pitaevskii equations for our system show that dephasing due to spatial dynamics driven by interparticle interactions account for much of the observed decay in fringe visibility at long interrogation times. The simulations show good agreement with the experimental data when additional technical decoherence is accounted for, and suggest that the clock states are indeed immiscible. With smaller samples of 5 \times 10^4 atoms, we observe a coherence time of τ = (1.0+0.5-0.3) s.

preprint2010arXiv

Quantum projection noise limited interferometry with coherent atoms in a Ramsey type setup

Every measurement of the population in an uncorrelated ensemble of two-level systems is limited by what is known as the quantum projection noise limit. Here, we present quantum projection noise limited performance of a Ramsey type interferometer using freely propagating coherent atoms. The experimental setup is based on an electro-optic modulator in an inherently stable Sagnac interferometer, optically coupling the two interfering atomic states via a two-photon Raman transition. Going beyond the quantum projection noise limit requires the use of reduced quantum uncertainty (squeezed) states. The experiment described demonstrates atom interferometry at the fundamental noise level and allows the observation of possible squeezing effects in an atom laser, potentially leading to improved sensitivity in atom interferometers.

preprint2010arXiv

Rb-85 tunable-interaction Bose-Einstein condensate machine

We describe our experimental setup for creating stable Bose-Einstein condensates of Rb-85 with tunable interparticle interactions. We use sympathetic cooling with Rb-87 in two stages, initially in a tight Ioffe-Pritchard magnetic trap and subsequently in a weak, large-volume crossed optical dipole trap, using the 155 G Feshbach resonance to manipulate the elastic and inelastic scattering properties of the Rb-85 atoms. Typical Rb-85 condensates contain 4 x 10^4 atoms with a scattering length of a=+200a_0. Our minimalist apparatus is well-suited to experiments on dual-species and spinor Rb condensates, and has several simplifications over the Rb-85 BEC machine at JILA (Papp, 2007; Papp and Wieman, 2006), which we discuss at the end of this article.

preprint2009arXiv

Experimental comparison of Raman and RF outcouplers for high flux atom lasers

We study the properties of an atom laser beam derived from a Bose-Einstein condensate using three different outcouplers, one based on multi-state radio frequency transitions and two others based on Raman transitions capable of imparting momentum to the beam. We first summarize the differences that arise in such systems, and how they may impact on the use of an atom laser in interferometry. Experimentally, we examine the formation of a bound state in all three outcouplers, a phenomenon which limits the atom laser flux, and find that a two-state Raman outcoupler is the preferred option for high flux, low divergence atom laser beams.

preprint2009arXiv

Measurement of inelastic losses in a sample of ultracold Rb-85

We report on the observation and characterisation of an inelastic loss feature in collisions between ultracold Rb-85 |F=2, m_F=-2> atoms at a magnetic field of 220 G. Our apparatus creates ultracold Rb-85 clouds by sympathetic cooling with a Rb-87 reservoir, and can produce pure Rb-87 condensates of 10^6 atoms by a combination of evaporative cooling in a quadrupole-Ioffe magnetic trap and further evaporation in a weak, large-volume optical dipole trap. By combining Rb-85 and Rb-87 atoms collected in a dual-species magneto-optical trap and selectively evaporating the heavier isotope, we demonstrate strong sympathetic cooling of the Rb-85 cloud, increasing its phase space density by three orders of magnitude with no detectable loss in number. We have used ultracold samples created in this way to observe the variation of inelastic loss in ultracold Rb-85 as a function of magnetic field near the 155 G Feshbach resonance. We have also measured a previously unobserved loss feature at 219.9(1) G with a width of 0.28(6) G, which we associate with a narrow Feshbach resonance predicted by theory.

preprint2009arXiv

Ramsey interferometry with an atom laser

We present results on a free-space atom interferometer operating on the first order magnetically insensitive |F=1,mF=0> -> |F=2,mF=0> transition of Bose-condensed 87Rb atoms. A pulsed atom laser is output-coupled from a Bose-Einstein condensate and propagates through a sequence of two internal state beam splitters, realized via coherent Raman transitions between the two interfering states. We observe Ramsey fringes with a visibility close to 100% and determine the current and the potentially achievable interferometric phase sensitivity. This system is well suited to testing recent proposals for generating and detecting squeezed atomic states.

preprint2005arXiv

A detector for continuous measurement of ultra-cold atoms in real time

We present the first detector capable of recording high-bandwidth real time atom number density measurements of a Bose Einstein condensate. Based on a two-color Mach-Zehnder interferometer, our detector has a response time that is six orders of magnitude faster than current detectors based on CCD cameras while still operating at the shot-noise limit. With this minimally destructive system it may be possible to implement feedback to stabilize a Bose-Einstein condensate or an atom laser.