Source author record

R. Oliveira

R. Oliveira appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

13works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

13 published item(s)

preprint2022arXiv

Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade

The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton collisions is expected to exceed $2-3\times10^{34}$~cm$^{-2}$s$^{-1}$ for Run 3 (starting in 2022), and it will be at least $5\times10^{34}$~cm$^{-2}$s$^{-1}$ when the High Luminosity Large Hadron Collider is completed for Run 4. These conditions will affect muon triggering, identification, and measurement, which are critical capabilities of the experiment. To address these challenges, additional muon detectors are being installed in the CMS endcaps, based on Gas Electron Multiplier technology. For this purpose, 161 large triple-Gas Electron Multiplier detectors have been constructed and tested. Installation of these devices began in 2019 with the GE1/1 station and will be followed by two additional stations, GE2/1 and ME0, to be installed in 2023 and 2026, respectively. The assembly and quality control of the GE1/1 detectors were distributed across several production sites around the world. We motivate and discuss the quality control procedures that were developed to standardize the performance of the detectors, and we present the final results of the production. Out of 161 detectors produced, 156 detectors passed all tests, and 144 detectors are now installed in the CMS experiment. The various visual inspections, gas tightness tests, intrinsic noise rate characterizations, and effective gas gain and response uniformity tests allowed the project to achieve this high success rate.

preprint2021arXiv

Modeling the triple-GEM detector response to background particles for the CMS Experiment

An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The simulation framework uses a combination of the FLUKA and Geant4 packages to obtain the hit rate. FLUKA provides the radiation environment around the GE1/1 chambers, which is comprised of the particle flux with momentum direction and energy spectra ranging from $10^{-11}$ to $10^{4}$ MeV for neutrons, $10^{-3}$ to $10^{4}$ MeV for $γ$'s, $10^{-2}$ to $10^{4}$ MeV for $e^{\pm}$, and $10^{-1}$ to $10^{4}$ MeV for charged hadrons. Geant4 provides an estimate of detector response (sensitivity) based on an accurate description of detector geometry, material composition and interaction of particles with the various detector layers. The MC simulated hit rate is estimated as a function of the perpendicular distance from the beam line and agrees with data within the assigned uncertainties of 10-14.5%. This simulation framework can be used to obtain a reliable estimate of background rates expected at the High Luminosity LHC.

preprint2020arXiv

Interstrip Capacitances of the Readout Board used in Large Triple-GEM Detectors for the CMS Muon Upgrade

We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequently maximize the signal-to-noise ratio for the detector. We find agreement at the 1.5--4.8% level between the two methods of calculations and on the average at the 17% level between calculations and measurements. A configuration with halved strip lengths and doubled strip widths results in a measured 27--29% reduction over the original configuration while leaving the total number of strips unchanged. We have now adopted this design modification for all eight module types of the GE2/1 detector and will produce the final detector with this new strip design.

preprint2013arXiv

Development of a new generation of micropattern gaseous detectors for high energy physics, astrophysics and environmental applications

We have developed a cost effective technology for manufacturing various layouts of micropattern gaseous detectors for a wide range of applications. Such devices feature resistive electrodes interfaced to a network of thin readout strips/electrodes. The following three examples of such innovative designs and their applications will be presented: a prototype of a novel double-phase LAr detector with a CsI photocathode immersed inside the LAr, a CsI-RICH detector prototype for ALICE upgrade and GEM-like sensors for environmental safety/security applications.

preprint2012arXiv

Development and preliminary tests of resistive microdot and microstrip detectors

In the last few years our group have focused on developing various designs of spark-protected micropattern gaseous detectors featuring resistive electrodes instead of the traditional metallic ones: resistive microstrip counters, resistive GEM, resistive MICROMEGAS. These detectors combine in one design the best features of RPCs (spark-protection) and micropattern detectors (a high position resolution). In this paper we report the progress so far made in developing other types of resistive micropattern detectors: a microdot-microhole detector and a microgap-microstrip detector. The former detector is an optimal electron amplifier for some special designs of dual phase noble liquid TPCs, for example with a CsI photocathode immersed inside the noble liquid. Preliminary tests of such a detector, for the first time built and investigated, are reported in this paper. The latter detector is mainly orientated towards medical imaging applications such as X-ray scanners. However, we believe that after a proper gas optimization, these detectors could also achieve a high time resolution and could thus be used in applications as TOF-PET, detection of charged particles with simultaneous high time and position resolution etc.

preprint2011arXiv

An improved design of spark-protected microstrip gas counters (R-MSGC)

We have developed microstrip gas counters manufactured on standard printed circuit board and having the following features: resistive cathode strips, thin (10 micron) metallic anode strips and electrodes protected against surface discharges by a Coverlay layer at their edges. These features allow the detector to operate at gas gains as high as can be achieve with the best microstrip gas counters manufactured on glass substrates. We believe that after further developments this type of detectors can compete in some applications with other micropattern detectors, for example MICROMEGAS.

preprint2011arXiv

Further developments and tests of microstrip gas counters with resistive electrodes

We present results from further tests of Microstrip Gas Counters (MSGCs) with resistive electrodes. The maim advantage of this detector is that it is spark-protected: in contrast to "classical" MSGCs with metallic electrodes, sparks in this new detector do not destroy its electrodes. As a consequence the MSGC with resistive electrodes is more reliable in operation which may open new avenues in applications. One of them which is under investigation now is the use of Resistive electrodes MSGC (R-MSGC) as photodetector in some particular designs of noble liquid dark matter detectors.

preprint2011arXiv

New designs of resistive microstrip gaseous detectors (R-MSGCs)

A new family of spark-protected micropattern gaseous detectors is introduced: a 2-D sensitive restive microstrip counter and hybrid detectors, which combine in one design a resistive GEM with a microstrip detector. These novel detectors have several important advantages over other conventional micropattern detectors and are unique for applications like the readout detectors for dual phase noble liquid TPCs and RICHs.

preprint2010arXiv

Advances in the Development of Micropattern Gaseous Detectors with Resistive Electrodes

We describe the most recent efforts made by various groups in implementing resistive electrodes in micropattern gaseous detectors with the aim to combine in the same design the best features of RPCs (for the example, their robustness and spark protection property) with the high granularity and thus the good position resolution offered by microelectronic technology. In the stream of this activity, we have recently developed two novel detectors with resistive electrodes: one was based on resistive micromeshes and the second one is a MSGC with resistive electrodes. We have demonstrated that the resistive meshes are a convenient construction element for various designs of spark protective detectors: RPCs type, GEM type and MICROMEGAS type. These new detectors enable to considerably enhance the RPC and micropattern detectors applications since they feature not only a high position resolution but also a relatively good energy resolution (25-30 persent FWHM at 6 keV) and, if necessary, they can operate in cascaded mode allowing the achievement of a high overall gas gain. The main conclusion from these studies is that the implementation of resistive electrodes in micropattern detectors makes them fully spark protected; on this basis we consider this direction very promising.

preprint2008arXiv

Progress in Developing Hybrid RPCs: GEM-like Detectors with Resistive Electrodes

We have recently developed an innovative detector of photons and charged particles: a GEM-like gaseous amplification structure with resistive electrodes instead of commonly used metallic ones. This novel detector combines the best property of GEMs- the capability to operate in a cascaded mode and in poorly quenched gases - and of RPC: the protection against sparks. In this paper will shortly review our latest achievements in this direction, however the main focus will be given on a new advanced design that allows to build large area detectors manufactured by a screen printing technology. The proposed detector, depending on the applications, can operate either in a GEM mode (electron multiplications through holes only) or as a hybrid RPC with simultaneous amplifications in the drift region and in the holes. The possible applications of this new detector will be discussed.

preprint2007arXiv

Efficient Generation of Generic Entanglement

We find that generic entanglement is physical, in the sense that it can be generated in polynomial time from two-qubit gates picked at random. We prove as the main result that such a process generates the average entanglement of the uniform (Haar) measure in at most $O(N^3)$ steps for $N$ qubits. This is despite an exponentially growing number of such gates being necessary for generating that measure fully on the state space. Numerics furthermore show a variation cut-off allowing one to associate a specific time with the achievement of the uniform measure entanglement distribution. Various extensions of this work are discussed. The results are relevant to entanglement theory and to protocols that assume generic entanglement can be achieved efficiently.