Source author record

R. J. Chen

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

7works
6topics
4close collaborators

Published work

7 publications

preprint2026arXiv

DeepSeek-R1: Incentivizing Reasoning Capability in LLMs via Reinforcement Learning

General reasoning represents a long-standing and formidable challenge in artificial intelligence. Recent breakthroughs, exemplified by large language models (LLMs) and chain-of-thought prompting, have achieved considerable success on foundational reasoning tasks. However, this success is heavily contingent upon extensive human-annotated demonstrations, and models' capabilities are still insufficient for more complex problems. Here we show that the reasoning abilities of LLMs can be incentivized through pure reinforcement learning (RL), obviating the need for human-labeled reasoning trajectories. The proposed RL framework facilitates the emergent development of advanced reasoning patterns, such as self-reflection, verification, and dynamic strategy adaptation. Consequently, the trained model achieves superior performance on verifiable tasks such as mathematics, coding competitions, and STEM fields, surpassing its counterparts trained via conventional supervised learning on human demonstrations. Moreover, the emergent reasoning patterns exhibited by these large-scale models can be systematically harnessed to guide and enhance the reasoning capabilities of smaller models.

preprint2022arXiv

Single and double KK-shell vacancy production in slow Xe54+,53+^\textrm{54+,53+}-Xe collisions

We present an experimental and theoretical study of symmetric Xe54++Xe\textrm{Xe}^{54+}+\textrm{Xe} collisions at 50, 30, and 15 MeV/u, corresponding to strong perturbations with vK/vpv_K/v_\text{p} = 1.20, 1.55, and 2.20, respectively (vKv_K: classical KK-shell orbital velocity, vpv_\text{p}: projectile velocity), as well as Xe53++Xe\textrm{Xe}^{53+}+\textrm{Xe} collisions at 15 MeV/u. For each of these systems, x-ray spectra were measured under a forward angle of 35∘35^\circ with respect to the projectile beam. Target satellite and hypersatellite radiation, Kα2,1sKα_{2,1}^\mathrm{s} and Kα2,1hsKα_{2,1}^\mathrm{hs}, respectively, were analyzed and used to derive cross section ratios for double-to-single target KK-shell vacancy production. We compare our experimental results to relativistic time-dependent two-center calculations.

preprint2020arXiv

Determination of luminosity for in-ring reactions: A new approach for the low-energy domain

Luminosity is a measure of the colliding frequency between beam and target and it is a crucial parameter for the measurement of absolute values, such as reaction cross sections. In this paper, we make use of experimental data from the ESR storage ring to demonstrate that the luminosity can be precisely determined by modelling the measured Rutherford scattering distribution. The obtained results are in good agreement with an independent measurement based on the x-ray normalization method. Our new method provides an alternative way to precisely measure the luminosity in low-energy stored-beam configurations. This can be of great value in particular in dedicated low-energy storage rings where established methods are difficult or impossible to apply.

preprint2019arXiv

Improving the resolving power of Isochronous Mass Spectrometry by employing an in-ring mechanical slit

Isochronous Mass Spectrometry (IMS) in heavy-ion storage rings is an excellent experimental method for precision mass measurements of exotic nuclei. In the IMS, the storage ring is tuned in a special isochronous ion-optical mode. Thus, the mass-over-charge ratios of the stored ions are directly reflected by their respective revolution times in first order. However, the inevitable momentum spread of secondary ions increases the peak widths in the measured spectra and consequently limits the achieved mass precision. In order to achieve a higher mass resolving power, the ring aperture was reduced to 60 mm by applying a mechanical slit system at the dispersive straight section. The momentum acceptance was reduced as well as better isochronous conditions were achieved. The results showed a significant improvement of the mass resolving power reaching 5.2×1055.2 \times 10^{5}, though at the cost of about 40\% ion loss.

preprint2016arXiv

An improvement of isochronous mass spectrometry: Velocity measurements using two time-of-flight detectors

Isochronous mass spectrometry (IMS) in storage rings is a powerful tool for mass measurements of exotic nuclei with very short half-lives down to several tens of microseconds, using a multicomponent secondary beam separated in-flight without cooling. However, the inevitable momentum spread of secondary ions limits the precision of nuclear masses determined by using IMS. Therefore, the momentum measurement in addition to the revolution period of stored ions is crucial to reduce the influence of the momentum spread on the standard deviation of the revolution period, which would lead to a much improved mass resolving power of IMS. One of the proposals to upgrade IMS is that the velocity of secondary ions could be directly measured by using two time-of-flight (double TOF) detectors installed in a straight section of a storage ring. In this paper, we outline the principle of IMS with double TOF detectors and the method to correct the momentum spread of stored ions.

preprint2016arXiv

Identification of the Lowest T=2T=2, Jπ=0+J^{π=}0^+ Isobaric Analog State in 52^{52}Co and Its Impact on the Understanding of ββ-Decay Properties of 52^{52}Ni

Masses of 52g,52m^{52g,52m}Co were measured for the first time with an accuracy of ∼10\sim 10 keV, an unprecedented precision reached for short-lived nuclei in the isochronous mass spectrometry. Combining our results with the previous ββ-γγ measurements of 52^{52}Ni, the T=2T=2, Jπ=0+J^π=0^+ isobaric analog state (IAS) in 52^{52}Co was newly assigned, questioning the conventional identification of IASs from the ββ-delayed proton emissions. Using our energy of the IAS in 52^{52}Co, the masses of the T=2T=2 multiplet fit well into the Isobaric Multiplet Mass Equation. We find that the IAS in 52^{52}Co decays predominantly via γγ transitions while the proton emission is negligibly small. According to our large-scale shell model calculations, this phenomenon has been interpreted to be due to very low isospin mixing in the IAS.

preprint2014arXiv

Accurate correction of magnetic field instabilities for high-resolution isochronous mass measurements in storage rings

Isochronous mass spectrometry (IMS) in storage rings is a successful technique for accurate mass measurements of short-lived nuclides with relative precision of about 10−5−10−710^{-5}-10^{-7}. Instabilities of the magnetic fields in storage rings are one of the major contributions limiting the achievable mass resolving power, which is directly related to the precision of the obtained mass values. A new data analysis method is proposed allowing one to minimise the effect of such instabilities. The masses of the previously measured at the CSRe 41^{41}Ti, 43^{43}V, 47^{47}Mn, 49^{49}Fe, 53^{53}Ni and 55^{55}Cu nuclides were re-determined with this method. An improvement of the mass precision by a factor of ∼1.7\sim 1.7 has been achieved for 41^{41}Ti and 43^{43}V. The method can be applied to any isochronous mass experiment irrespective of the accelerator facility. Furthermore, the method can be used as an on-line tool for checking the isochronous conditions of the storage ring.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.