Source author record

Piotr Masłowski

Piotr Masłowski appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2019arXiv

Intensity Noise Optimization of a Mid-Infrared Frequency Comb Difference Frequency Generation Source

We experimentally demonstrate in a difference-frequency generation mid-infrared frequency comb source the effect of temporal overlap between pump- and signal- pulse to the relative intensity noise (RIN) of the idler pulse. When scanning the temporal delay between our 130 fs long signal- and pump pulses, we observe a RIN minimum with a 3 dB width of 20 fs delay and an RIN increase of 20 dB in 40 fs delay at the edges of this minimum. We also demonstrate active long-term stabilization of the mid-infrared frequency comb source to the temporal overlap setting corresponding to the lowest RIN operation point by an on-line RIN-detector and active feedback control of the pump-signal- pulse delay. This active stabilization set-up allowed us to dramatically increase the signal-to-noise ratio of mid-infrared absorption spectra.

preprint2010arXiv

Mid-Infrared Frequency Comb Fourier Transform Spectrometer

Optical frequency-comb-based-high-resolution spectrometers offer enormous potential for spectroscopic applications. Although various implementations have been demonstrated, the lack of suitable mid-infrared comb sources has impeded explorations of molecular fingerprinting. Here we present for the first time a frequency-comb Fourier transform spectrometer operating in the 2100-to-3700-cm-1 spectral region that allows fast and simultaneous acquisitions of broadband absorption spectra with up to 0.0056 cm-1 resolution. We demonstrate part-per-billion detection limits in 30 seconds of integration time for various important molecules including methane, ethane, isoprene, and nitrous oxide. Our system enables precise concentration measurements even in gas mixtures that exhibit continuous absorption bands, and it allows detection of molecules at levels below the noise floor via simultaneous analysis of multiple spectral features. This system represents a near real-time, high-resolution, high-bandwidth mid-infrared spectrometer which is ready to replace traditional Fourier transform spectrometers for many applications in trace gas detection, atmospheric science, and medical diagnostics.