Source author record

Florian Adler

Florian Adler appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2019arXiv

Tailoring the topological surface state in ultrathin $α$-Sn (111) films

We report on the electronic structure of $α$-Sn films in the very low thickness regime grown on InSb(111)A. High-resolution low photon energies angle-resolved photoemission (ARPES) allows for the direct observation of the linearly dispersing 2D topological surface states (TSSs) that exist between the second valence band and the conduction band. The Dirac point of this TSS was found to be 200meV below the Fermi level in 10-nm-thick $α$-Sn films, which enables the observation of the hybridization gap opening at the Dirac point of the TSS for thinner films. The crossover to a quasi-2D electronic structure is accompanied by a full gap opening at the Brillouin zone center, in agreement with our density functional theory calculations. We further identify the thickness regime of $α$-Sn films where the hybridization gap in TSS coexists with the topologically non-trivial electronic structure and one can expect the presence of a 1D helical edge states.

preprint2015arXiv

Triangular Spin-Orbit-Coupled Lattice with Strong Coulomb Correlations: Sn Atoms on a SiC(0001) Substrate

Two-dimensional (2D) atom lattices provide model setups for Coulomb correlations inducing competing ground states, partly with topological character. Hexagonal SiC(0001) is an intriguing wide-gap substrate, spectroscopically separated from the overlayer and hence reduced screening. We report the first study of an artificial high-Z atom lattice on SiC(0001) by Sn adatoms, based on combined experimental realization and theoretical modeling. Density-functional theory of our $\sqrt{3}$-structure model closely reproduces the scanning tunneling microscopy. Instead of metallic behavior, photoemission data show a deeply gapped state (~2 eV gap). Based on our calculations including dynamic mean-field theory, we argue that this reflects a pronounced Mott insulating scenario. We also find indications that the system is susceptible to antiferromagnetic superstructures. Such spin-orbit-coupled correlated heavy atom lattices on SiC(0001) thus form a novel testbed for peculiar quantum states of matter, with potential bearing for spin liquids and topological Mott insulators.

preprint2012arXiv

High-power, hybrid Er:fiber/Tm:fiber frequency comb source in the 2 μm wavelength region

We present a 2-\mum frequency comb based on a reliable mode-locked Er:fiber laser with 100 MHz repetition rate. After shifting the spectrum of the amplified Er:fiber comb to longer wavelengths, a single-clad Tm/Ho:fiber is used as a self-pumped pre-amplifier to generate a coherent and broadband spectrum centered at 1.93 \mum. Subsequently, a cladding-pumped Tm:fiber amplifier boosts the system to a maximum output power of 4.8 W at 1.96 \mum. After compression in a compact grating compressor, our amplified Er:fiber/Tm:fiber hybrid system delivers as much as 2.9 W with a pulse duration of 141 fs. The system's comb properties are examined via heterodyne measurement.

preprint2012arXiv

Mid-infrared VIPA Spectrometer for Rapid and Broadband Trace Gas Detection

We present and characterize a 2-D imaging spectrometer based on a virtually-imaged phased array (VIPA) disperser for rapid, high-resolution molecular detection using mid-infrared (MIR) frequency combs at 3.1 and 3.8 μm. We demonstrate detection of CH4 at 3.1 μm with >3750 resolution elements spanning >80 nm with ~600 MHz resolution in a <10 μs acquisition time. In addition to broadband detection, rapid, time-resolved single-image detection is demonstrated by capturing dynamic concentration changes of CH4 at a rate of ~375 frames per second. Changes in absorption above the noise floor of 5\times 10-4 are readily detected on the millisecond time scale, leading to important future applications such as real time monitoring of trace gas concentrations and detection of reactive intermediates.

preprint2011arXiv

Quantum-noise-limited optical frequency comb spectroscopy

We achieve a quantum-noise-limited absorption sensitivity of 1.7/times10$^{-12}$ cm$^{-1}$ per spectral element at 400 s of acquisition time with cavity-enhanced frequency comb spectroscopy, the highest demonstrated for a comb-based technique. The system comprises a frequency comb locked to a high-finesse cavity and a fast-scanning Fourier transform spectrometer with an ultra-low-noise autobalancing detector. Spectra with a signal-to-noise ratio above 1000 and a resolution of 380 MHz are acquired within a few seconds. The measured absorption lineshapes are in excellent agreement with theoretical predictions.

preprint2010arXiv

Analysis of Trace Impurities in Semiconductor Gas via Cavity-Enhanced Direct Frequency Comb Spectroscopy

Cavity-enhanced direct frequency comb spectroscopy (CE-DFCS) has demonstrated powerful potential for trace gas detection based on its unique combination of high bandwidth, rapid data acquisition, high sensitivity, and high resolution, which is unavailable with conventional systems. However, previous demonstrations have been limited to proof-of-principle experiments or studies of fundamental laboratory science. Here we present the development of CE-DFCS towards an industrial application -- measuring impurities in arsine, an important process gas used in III-V semiconductor compound manufacturing. A strongly absorbing background gas with an extremely complex, congested, and broadband spectrum renders trace detection exceptionally difficult, but the capabilities of CE-DFCS overcome this challenge and make it possible to identify and quantify multiple spectral lines associated with water impurities. Further, frequency combs allow easy access to new spectral regions via efficient nonlinear optical processes. Here, we demonstrate detection of multiple potential impurities across 1.75-1.95 um (5710-5130 cm-1) with single-channel detection sensitivities of ~1 x 10-7 cm-1 Hz-1/2 in nitrogen and identify water doped in arsine with a sensitivity of ~1 x 10-6 cm-1 Hz-1/2.

preprint2010arXiv

Mid-Infrared Frequency Comb Fourier Transform Spectrometer

Optical frequency-comb-based-high-resolution spectrometers offer enormous potential for spectroscopic applications. Although various implementations have been demonstrated, the lack of suitable mid-infrared comb sources has impeded explorations of molecular fingerprinting. Here we present for the first time a frequency-comb Fourier transform spectrometer operating in the 2100-to-3700-cm-1 spectral region that allows fast and simultaneous acquisitions of broadband absorption spectra with up to 0.0056 cm-1 resolution. We demonstrate part-per-billion detection limits in 30 seconds of integration time for various important molecules including methane, ethane, isoprene, and nitrous oxide. Our system enables precise concentration measurements even in gas mixtures that exhibit continuous absorption bands, and it allows detection of molecules at levels below the noise floor via simultaneous analysis of multiple spectral features. This system represents a near real-time, high-resolution, high-bandwidth mid-infrared spectrometer which is ready to replace traditional Fourier transform spectrometers for many applications in trace gas detection, atmospheric science, and medical diagnostics.

preprint2009arXiv

Phase-stabilized, 1.5-W frequency comb at 2.8 to 4.8 micron

We present a high-power optical parametric oscillator-based frequency comb in the mid-infrared wavelength region using periodically poled lithium niobate. The system is synchronously pumped by a 10-W femtosecond Yb:fiber laser centered at 1.07 um and is singly resonant for the signal. The idler (signal) wavelength can be continuously tuned from 2.8 to 4.8 um (1.76 to 1.37 um) with a simultaneous bandwidth as high as 0.3 um and a maximum average idler output power of 1.50 W. We also demonstrate the performance of the stabilized comb by recording the heterodyne beat with a narrow-linewidth diode laser. This OPO is an ideal source for frequency comb spectroscopy in the mid-IR.