Researcher profile

Peng Xiao

Peng Xiao contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

Excitation and detection of acoustic phonons in nanoscale systems

Phonons play a key role in the physical properties of materials, and have long been a topic of study in physics. While the effects of phonons had historically been considered to be a hindrance, modern research has shown that phonons can be exploited due to their ability to couple to other excitations and consequently affect the thermal, dielectric, and electronic properties of solid state systems, greatly motivating the engineering of phononic structures. Advances in nanofabrication have allowed for structuring and phonon confinement even down to the nanoscale, drastically changing material properties. Despite developments in fabricating such nanoscale devices, the proper manipulation and characterization of phonons continues to be challenging. However, a fundamental understanding of these processes could enable the realization of key applications in diverse fields such as topological phononics, information technologies, sensing, and quantum electrodynamics, especially when integrated with existing electronic and photonic devices. Here, we highlight seven of the available methods for the excitation and detection of acoustic phonons and vibrations in solid materials, as well as advantages, disadvantages, and additional considerations related to their application. We then provide perspectives towards open challenges in nanophononics and how the additional understanding granted by these techniques could serve to enable the next generation of phononic technological applications.

preprint2022arXiv

Graph-based Matched Field Localization for an Underwater Source

Matched Field Processing (MFP) locates the underwater sources by matching the received data with the replica vectors, which could be regarded as a generalized beamformer. In this paper, the MFP method is combined with a recently developed framework -- Graph Signal Processing (GSP) method. Following the paradigm of GSP, a spatial adjacency matrix is constructed for the arbitrary distributed sensors based on the Green's function, then the source is located by utilizing the graph Fourier transform. The simulation results illustrate that the Graph-based MFP outperforms the the conventional MFP processors -- the Bartlett processor and the Minimum Variance processor -- for its good accuracy and robustness.

preprint2022arXiv

Thermal insulation and heat guiding using nanopatterned MoS2

In the modern electronics overheating is one of the major reasons for device failure. Overheating causes irreversible damage to circuit components and can also lead to fire, explosions, and injuries. Accordingly, in the advent of 2D material-based electronics, an understanding of their thermal properties in addition to their electric ones is crucial to enable efficient transfer of excess heat away from the electronic components. In this work we propose structures based on free-standing, few-layer, nanopatterned MoS2 that insulate and guide heat in the in-plane direction. We arrive at these designs via a thorough study of the in-plane thermal conductivity as a function of thickness, porosity, and temperature in both pristine and nanopatterned MoS2 membranes. Two-laser Raman thermometry was employed to measure the thermal conductivities of a set of free-standing MoS2 flakes with diameters greater than 20 um and thicknesses from 5 to 40 nm, resulting in values from 30 to 85 W/mK, respectively. After nanopatterning a square lattice of 100-nm diameter holes with a focused ion beam we have obtained a greater than 10-fold reduction of the thermal conductivities for the period of 500 nm and values below 1 W/mK for the period of 300 nm. The results were supported by equilibrium molecular dynamic simulations for both pristine and nanopatterned MoS2. The selective patterning of certain areas results in extremely large difference in thermal conductivities within the same material. Exploitation of this effect enabled for the first time thermal insulation and heat guiding in the few-layer MoS2. The patterned regions act as high thermal resistors: we obtained a thermal resistance of 4x10-6 m2K/W with only four patterned lattice periods of 300 nm, highlighting the significant potential of MoS2 for thermal management applications.

preprint2021arXiv

Optical phase modulation by natural eye movements: application to time-domain FF-OCT image retrieval

Eye movements are commonly seen as an obstacle to high-resolution ophthalmic imaging. In this context we study the natural axial movements of the in vivo human eye and show that they can be used to modulate the optical phase and retrieve tomographic images via time-domain full-field optical coherence tomography (TD-FF-OCT). This approach opens a path to a simplified ophthalmic TD-FF-OCT device, operating without the usual piezo motor-camera synchronization. The device demonstrates in vivo human corneal images under the different image retrieval schemes (2-phase and 4-phase) and different exposure times (3.5 ms, 10 ms, 20 ms). Data on eye movements, acquired with a 100 kHz spectral-domain OCT with axial eye tracking, are used to study the influence of ocular motion on the probability of capturing high-signal tomographic images without phase washout. The optimal combinations of camera acquisition speed and amplitude of piezo modulation are proposed and discussed.

preprint2021arXiv

Potential Advantages of Peak Picking Multi-Voltage Threshold Digitizer in Energy Determination in Radiation Measurement

The Multi-voltage Threshold (MVT) method, which samples the signal by certain reference voltages, has been well developed as being adopted in pre-clinical and clinical digital positron emission tomography(PET) system. To improve its energy measurement performance, we propose a Peak Picking MVT(PP-MVT) Digitizer in this paper. Firstly, a sampled Peak Point(the highest point in pulse signal), which carries the values of amplitude feature voltage and amplitude arriving time, is added to traditional MVT with a simple peak sampling circuit. Secondly, an amplitude deviation statistical analysis, which compares the energy deviation of various reconstruction models, is used to select adaptive reconstruction models for signal pulses with different amplitudes. After processing 30,000 randomly-chosen pulses sampled by the oscilloscope with a 22Na point source, our method achieves an energy resolution of 17.50% within a 450-650 KeV energy window, which is 2.44% better than the result of traditional MVT with same thresholds; and we get a count number at 15225 in the same energy window while the result of MVT is at 14678. When the PP-MVT involves less thresholds than traditional MVT, the advantages of better energy resolution and larger count number can still be maintained, which shows the robustness and the flexibility of PP-MVT Digitizer. This improved method indicates that adding feature peak information could improve the performance on signal sampling and reconstruction, which canbe proved by the better performance in energy determination in radiation measurement.

preprint2020arXiv

Ocean Reverberation Suppression via Matrix Completion with Sensor Failure

In the ocean environment, reverberation is a common and strong interference which significantly degrades the performance of target bearing estimation. Meanwhile, sensor failure is inevitable in actual sonar deployment as the underwater scene is complicated. Therefore, it is a challenge for target detection in the ocean reverberation with sensor failure. To address this issue, we propose an improved approach based on the principle of low rank characteristics of matrix in this paper. Firstly, we utilize Hankel structured matrix to counteract the problem of sensor failure. Then, the algorithm of matrix completion (MC) based on l1-norm and l2-norm are exploited to recover the true signal matrix from the corrupted received matrix. Numerical results demonstrate that compared with other related methods, the l1-norm provides better capability in the probability of recovery and shows the best robustness of bearing estimation with the narrow beam width and low sidelobe. Moreover, the proposed approach verifies the performances of reverberation suppression and achieves high resolution of target detection.

preprint2020arXiv

Real-time, non-contact, cellular imaging and angiography of human cornea and limbus with common-path Full-field/SDOCT

In today's clinics, a cellular-resolution view of the cornea can be achieved only with an in vivo confocal microscope (IVCM) in contact with the eye. Here, we present a common-path Full-field/Spectral-domain OCT microscope (FF/SD OCT), which, for the first time, enables cell-detail imaging of the entire ocular surface (central and peripheral cornea, limbus, sclera, tear film) without contact and in real time. The device, which has been successfully tested in human subjects, is now ready for direct implementation in clinical research. Real-time performance is achieved through rapid axial eye tracking and simultaneous defocusing correction. Images, extracted from real-time videos, contain cells and nerves, which can be quantified over a millimetric field-of-view, beyond the capability of IVCM and conventional OCT. In the limbus, Palisades of Vogt, vessels and blood flow can be resolved with high contrast without contrast agent injection. The fast imaging speed of 275 frames/s (0.6 billion pixels/s) allowed direct monitoring of blood flow dynamics, enabling creation of high-resolution velocity maps for the first time. Tear flow velocity and evaporation time could be measured without fluorescein administration.