Researcher profile

Paul Fuoss

Paul Fuoss contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Generation of highly mutually coherent hard x-ray pulse pairs with an amplitude-splitting delay line

Beam splitters and delay lines are among the key building blocks of modern-day optical laser technologies. Progress in x-ray free electron laser source development and applications over the past decade is calling for their counter part operating in the Angstrom wavelength regime. Recent efforts in x-ray optics development have demonstrated relatively stable delay lines that most often adopted the division of wavefront approach for the beam splitting and recombination configuration. However, the two recombined beams have yet to achieve sufficient mutual coherence to enable applications such as interferometry, correlation spectroscopy, and nonlinear spectroscopy. We present the first experimental realization of the generation of highly mutually coherent pulse pairs using an amplitude-split delay line design based on transmission grating beam splitters and channel-cut crystal optic delay lines. The performance of the prototype system was analyzed in the context of x-ray coherent scattering and correlation spectroscopy, where we obtained nearly identical high-contrast speckle patterns from both branches. We show in addition the high level of dynamical stability during continuous delay scans, a capability essential for high sensitivity ultra-fast measurements.

preprint2022arXiv

Structural changes across thermodynamic maxima in supercooled liquid tellurium: a water-like scenario

Liquid polymorphism is an intriguing phenomenon which has been found in a few single-component systems, the most famous being water. By supercooling liquid Te to more than 130 K below its melting point and performing simultaneous small-angle and wide-angle X-ray scattering measurements, we observe clear maxima in its thermodynamic response functions around 615 K, suggesting the possible existence of liquid polymorphism. A close look at the underlying structural evolution shows the development of intermediate-range order upon cooling, most strongly around the thermodynamic maxima, which we attribute to bond-orientational ordering. The striking similarities between our results and those of water, despite the lack of hydrogen-bonding and tetrahedrality in tellurium, indicate that water-like anomalies may be a general phenomenon among liquid systems with competing bond- and density-ordering.

preprint2020arXiv

Realizing split-pulse x-ray photon correlation spectroscopy to measure ultrafast dynamics in complex matter

Split-pulse x-ray photon correlation spectroscopy has been proposed as one of the unique capabilities made possible with the x-ray free electron lasers. It enables characterization of atomic scale structural dynamics that dictates the macroscopic properties of various disordered material systems. Central to the experimental concept are x-ray optics that are capable of splitting individual coherent femtosecond x-ray pulse into two distinct pulses, introduce an adjustable time delay between them, and then recombine the two pulses at the sample position such that they generate two coherent scattering patterns in rapid succession. Recent developments in such optics showed that, while true 'amplitude splitting' optics at hard x-ray wavelengths remains a technical challenge, wavefront and wavelength splitting are both feasible, able to deliver two micron sized focused beams to the sample with sufficient relative stability. Here, we however show that the conventional approach to speckle visibility spectroscopy using these beam splitting techniques can be problematic, even leading to a decoupling of speckle visibility and material dynamics. In response, we discuss the details of the experimental approaches and data analysis protocols for addressing issues caused by subtle beam dissimilarities for both wavefront and wavelength splitting setups. We also show that in some scattering geometries, the Q-space mismatch can be resolved by using two beams of slightly different incidence angle and slightly different wavelengths at the same time. Instead of measuring the visibility of weak speckle patterns, the time correlation in sample structure is encoded in the 'side band' of the spatial autocorrelation of the summed speckle patterns, and can be retrieved straightforwardly from the experimental data. We demonstrate this with a numerical simulation.