Researcher profile

Octavian Sima

Octavian Sima contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - Baseline
9works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2020arXiv

Restoration of azimuthal symmetry of muon densities in extended air showers

At ground level, the azimuthal distribution of muons in inclined Extensive Air Showers (EAS) is asymmetric, mainly due to geometric effects. Several EAS observables sensitive to the primary particle mass, are constructed after mapping the density of secondary particles from the ground plane to the shower plane (perpendicular to the shower axis). A simple orthogonal projection of the muon coordinates onto this plane distorts the azimuthal symmetry in the shower plane. Using CORSIKA simulations, we correct for this distortion by projecting each muon onto the normal plane following its incoming direction, taking also into account the attenuation probability. We show that besides restoring the azimuthal symmetry of muons density around the shower axis, the application of this procedure has a significant impact on the reconstruction of the distribution of the muon production depth and of its maximum, $X_{\rm max}^μ$, which is an EAS observable sensitive to the primary particle mass. Our results qualitatively suggest that not including it in the reconstruction process of $X_{\rm max}^μ$ may introduce a bias in the results obtained by analyzing the actual data on the basis of Monte Carlo simulations.

preprint2020arXiv

UHECRs mass composition from $X_{\rm max}$ distributions

The atmospheric depth where the energy deposit profile of secondary particles from extensive air showers (EAS) reaches its maximum, $X_{\rm max}$, is related to the primary particle mass. The mass composition of the ultra-high energy cosmic rays (UHECRs) can be inferred from measurements of $X_{\rm max}$ distributions in each energy interval, by fitting these distributions with Monte Carlo (MC) templates for four primary species (p, He, N and Fe). On the basis of simulations, we show that a high abundance of some intermediate elements in the $X_{\rm max}$ distributions, e.g. Ne or Si, may affect the quality of the fit and also the reconstructed fractions of different species with respect to their true values. We propose a method for finding the "best combination" of elements in each energy interval from a larger set of primaries (p, He, C, N, O, Ne, Si and Fe) which best describes the $X_{\rm max}$ distributions. Applying this method to the $X_{\rm max}$ distributions measured by the Pierre Auger Observatory (2014), we found that the "best combination" of elements which best describe the data suggest the presence of Ne or Si in some low energy bins for the EPOS-LHC model.

preprint2016arXiv

Energy Estimation of Cosmic Rays with the Engineering Radio Array of the Pierre Auger Observatory

The Auger Engineering Radio Array (AERA) is part of the Pierre Auger Observatory and is used to detect the radio emission of cosmic-ray air showers. These observations are compared to the data of the surface detector stations of the Observatory, which provide well-calibrated information on the cosmic-ray energies and arrival directions. The response of the radio stations in the 30 to 80 MHz regime has been thoroughly calibrated to enable the reconstruction of the incoming electric field. For the latter, the energy deposit per area is determined from the radio pulses at each observer position and is interpolated using a two-dimensional function that takes into account signal asymmetries due to interference between the geomagnetic and charge-excess emission components. The spatial integral over the signal distribution gives a direct measurement of the energy transferred from the primary cosmic ray into radio emission in the AERA frequency range. We measure 15.8 MeV of radiation energy for a 1 EeV air shower arriving perpendicularly to the geomagnetic field. This radiation energy -- corrected for geometrical effects -- is used as a cosmic-ray energy estimator. Performing an absolute energy calibration against the surface-detector information, we observe that this radio-energy estimator scales quadratically with the cosmic-ray energy as expected for coherent emission. We find an energy resolution of the radio reconstruction of 22% for the data set and 17% for a high-quality subset containing only events with at least five radio stations with signal.

preprint2016arXiv

Measurement of the Radiation Energy in the Radio Signal of Extensive Air Showers as a Universal Estimator of Cosmic-Ray Energy

We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 \pm 0.7 (stat) \pm 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principle calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.

preprint2016arXiv

Simulation study of the correlation ($X_{max}^μ$, $N^μ$) in view of obtaining information on primary mass of the UHECRs

In this paper we study, using Monte Carlo simulations, the possibility to discriminate the mass of the Ultra High Energy Cosmic Rays (UHECRs) by combining information obtained from the maximum $X_{max}^μ$ of the muon production rate longitudinal profile of Extensive Air Showers (EAS) and the number of muons, $N^μ$, which hit an array of detectors located in the horizontal plane. We investigate the sensitivity of the 2D distribution $X_{max}^μ$ versus $N^μ$ to the mass of the primary particle generating the air shower. To this purpose we analyze a set of CORSIKA showers induced by protons and iron nuclei at energies of $10^{19}$eV and $10^{20}$eV, at five angles of incidence, $0^{\circ}$, $37^{\circ}$, $48^{\circ}$, $55^{\circ}$ and $60^{\circ}$. Using the simulations we obtain the 2D Probability Functions $Prob(X_{max}^μ,N^μ \ | \ p)$ and $Prob(X_{max}^μ,N^μ \ | \ Fe)$ which give the probability that a shower induced by a proton or iron nucleus contributes to a specific point on the plane ($X_{max}^μ$, $N^μ$). Then we construct the probability functions $Prob(p\ | \ X_{max}^μ,N^μ)$ and $Prob(Fe \ | \ X_{max}^μ,N^μ)$ which give the probability that a certain point on the plane ($X_{max}^μ$, $N^μ$) corresponds to a shower initiated by a proton or an iron nucleus, respectively. Finally, a test of this procedure using a Bayesian approach, confirms an improved accuracy of the primary mass estimation in comparison with the results obtained using only the $X_{max}^μ$ distributions.

preprint2015arXiv

An improved limit to the diffuse flux of ultra-high energy neutrinos from the Pierre Auger Observatory

Neutrinos in the cosmic ray flux with energies near 1 EeV and above are detectable with the Surface Detector array of the Pierre Auger Observatory. We report here on searches through Auger data from 1 January 2004 until 20 June 2013. No neutrino candidates were found, yielding a limit to the diffuse flux of ultra-high energy neutrinos that challenges the Waxman-Bahcall bound predictions. Neutrino identification is attempted using the broad time-structure of the signals expected in the SD stations, and is efficiently done for neutrinos of all flavors interacting in the atmosphere at large zenith angles, as well as for &#34;Earth-skimming&#34; neutrino interactions in the case of tau neutrinos. In this paper the searches for downward-going neutrinos in the zenith angle bins $60^\circ-75^\circ$ and $75^\circ-90^\circ$ as well as for upward-going neutrinos, are combined to give a single limit. The $90\%$ C.L. single-flavor limit to the diffuse flux of ultra-high energy neutrinos with an $E^{-2}$ spectrum in the energy range $1.0 \times 10^{17}$ eV - $2.5 \times 10^{19}$ eV is $E_ν^2 dN_ν/dE_ν< 6.4 \times 10^{-9}~ {\rm GeV~ cm^{-2}~ s^{-1}~ sr^{-1}}$.

preprint2015arXiv

Measurement of the cosmic ray spectrum above $4{\times}10^{18}$ eV using inclined events detected with the Pierre Auger Observatory

A measurement of the cosmic-ray spectrum for energies exceeding $4{\times}10^{18}$ eV is presented, which is based on the analysis of showers with zenith angles greater than $60^{\circ}$ detected with the Pierre Auger Observatory between 1 January 2004 and 31 December 2013. The measured spectrum confirms a flux suppression at the highest energies. Above $5.3{\times}10^{18}$ eV, the &#34;ankle&#34;, the flux can be described by a power law $E^{-γ}$ with index $γ=2.70 \pm 0.02 \,\text{(stat)} \pm 0.1\,\text{(sys)}$ followed by a smooth suppression region. For the energy ($E_\text{s}$) at which the spectral flux has fallen to one-half of its extrapolated value in the absence of suppression, we find $E_\text{s}=(5.12\pm0.25\,\text{(stat)}^{+1.0}_{-1.2}\,\text{(sys)}){\times}10^{19}$ eV.

preprint2014arXiv

$X_{max}^μ$ vs. $N^μ$ from Extensive Air Showers as estimator for the mass of primary UHECR&#39;s. Application for the Pierre Auger Observatory

We study the possibility of primary mass estimation for Ultra High Energy Cosmic Rays (UHECR&#39;s) using the $X_{max}^μ$ (the height where the number of muons produced on the core of Extensive Air Showers (EAS) is maximum) and the number $N^μ$ of muons detected on ground. We use the 2D distribution - $X_{max}^μ$ against $N^μ$ in order to find its sensitivity to the mass of the primary particle. For that, we construct a 2D Probability Function $Prob(p,Fe \ | \ X_{max}^μ,N^μ)$ which estimates the probability that a certain point from the plane $(X_{max}^μ$, $N^μ)$ corresponds to a shower induced by a proton, respectively an iron nucleus. To test the procedure, we analyze a set of simulated EAS induced by protons and iron nuclei at energies of $10^{19} eV$ and $20^{\circ}$ zenith angle with CORSIKA. Using the Bayesian approach and taking into account the geometry of the infill detectors from the Pierre Auger Observatory, we observe an improvement in the accuracy of the primary mass reconstruction in comparison with the results obtained using only the $X_{max}^μ$ distributions.

preprint2011arXiv

A mobile detector for measurements of the atmospheric muon flux in underground sites

Muons comprise an important contribution of the natural radiation dose in air (approx. 30 nSv/h of a total dose rate of 65-130 nSv/h), as well as in underground sites even when the flux and relative contribution are significantly reduced. The flux of the muons observed in underground can be used as an estimator for the depth in mwe (meter water equivalent) of the underground site. The water equivalent depth is an important information to devise physics experiments feasible for a specific site. A mobile detector for performing measurements of the muon&#39;s flux was developed in IFIN-HH, Bucharest. Consisting of 2 scintillator plates (approx. 0.9 m2) which measure in coincidence, the detector is installed on a van which facilitates measurements at different locations at surface or underground. The detector was used to determine muon fluxes at different sites in Romania. In particular, data were taken and the values of meter water equivalents were assessed for several locations from the salt mine from Slanic Prahova, Romania. The measurements have been performed in 2 different galleries of the Slanic mine at different depths. In order to test the stability of the method, also measure- ments of the muon flux at surface at different elevations were performed. The results were compared with predictions of Monte-Carlo simulations using the CORSIKA and MUSIC codes.