Source author record

Michel Paques

Michel Paques appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2020arXiv

Curved-field optical coherence tomography: large-field imaging of human corneal cells and nerves

High-resolution optical imaging methods, such as confocal microscopy and full-field optical coherence tomography, capture flat optical sections of the sample. If the sample is curved, the optical field sections through several sample layers and the view of each layer is reduced. Here we present curved-field optical coherence tomography, capable of capturing optical sections of arbitrary curvature. We test the device on a challenging task of imaging the human cornea in vivo and achieve 10x larger viewing area comparing to the clinical state-of-the-art. This enables more precise cell and nerve counts, opening a path to improved diagnosis of corneal and general health conditions (e.g. diabetes). The method is non-contact, compact and works in a single-shot, making it readily available for use in optical research and clinical practice.

preprint2020arXiv

Optical Incoherence Tomography: a method to generate tomographic retinal cross-sections with non-interferometric imaging systems

Optical tomographic cross-sectional images of biological samples were made possible by interferometric imaging techniques such as Optical Coherence Tomography (OCT). Owing to its unprecedented view of the sample, OCT has become a gold standard, namely for human retinal imaging in the clinical environment. In this Letter, we present Optical Incoherence Tomography (OIT): a completely digital method extending the possibility to generate tomographic retinal cross-sections to non-interferometric imaging systems such as en-face AO-ophthalmoscopes. We demonstrate that OIT can be applied to different imaging modalities using back-scattered and multiply-scattered light including systems without inherent optical sectioning. We show that OIT can be further used to guide focus position when the user is "blind" focusing, allowing precise imaging of translucent retinal structures, the vascular plexuses and the retinal pigment epithelium using respectively split detection, motion contrast, and autofluorescence techniques.

preprint2020arXiv

Real-time digital holography of the retina by principal component analysis

We demonstrate the feasibility of high-quality digital holography of the human retina in real-time with a fast camera and commodity computer hardware. High throughput rendering of digital Fresnel holograms from optically-acquired inline interferograms is performed in conjunction with temporal demodulation by projection of hologram sequences onto a data-derived basis in order to discriminate local narrowband coherent detection contrasts, mostly due to blood flow and optical absorption, from spurious interferometric contributions. Digital holograms are calculated from a sustained input stream of 16-bit, 1024-by-1024-pixel interferograms recorded at up to 500 frames per second, processed by principal component analysis. This temporal signal demodulation scheme consists in the projection of stacks of 32 consecutive holograms onto a basis calculated by eigendecomposition of the matrix of their time-lagged covariance; it is performed up to 20 times per second with commodity computer hardware.

preprint2020arXiv

Reverse contrast laser Doppler holography for lower frame rate retinal and choroidal blood flow imaging

Laser Doppler holography (LDH) is an interferometric blood flow imaging technique based on full-field measurements of the Doppler spectrum. LDH has so far been demonstrated in the retina with ultrafast cameras, typically at 75 kHz. We show here that a similar method can be implemented with camera frame rates 10 times slower than before. Thanks to energy conservation, low and high frequency local power Doppler signals have opposite variations, and a simple contrast inversion of the low frequency power Doppler reveals fast blood flow beyond the camera detection bandwidth for conventional laser Doppler measurements. Relevant blood flow variations and color composite power Doppler images can be obtained with camera frame rates down to a few kHz.

preprint2020arXiv

Spatio-temporal filtering in laser Doppler holography for retinal blood flow imaging

Laser Doppler holography (LDH) is a full-field interferometric imaging technique recently applied in ophthalmology to measure blood flow, a parameter of high clinical interest. From the temporal fluctuations of digital holograms acquired at ultrafast frame rates, LDH reveals retinal and choroidal blood flow with a few milliseconds of temporal resolution. However LDH experiences difficulties to detect slower blood flow as it requires to work with low Doppler frequency shifts which are corrupted by eye motion. We here demonstrate the use of a spatio-temporal decomposition adapted from Doppler ultrasound that provides a basis appropriate to the discrimination of blood flow from eye motion. A singular value decomposition (SVD) can be used as a simple, robust, and efficient way to separate the Doppler fluctuations of blood flow from those of strong spatial coherence such as eye motion. We show that the SVD outperforms the conventional Fourier based filter to reveal slower blood flow, and dramatically improves the ability of LDH to reveal vessels of smaller size or with a pathologically reduced blood flow.

preprint2019arXiv

Jointly super-resolved and optically sectioned Bayesian reconstruction method for structured illumination microscopy

Structured Illumination Microscopy (SIM) is an imaging technique for achieving both super-resolution (SR) and optical sectioning (OS) in wide-field microscopy. It consists in illuminating the sample with periodic patterns at different orientations and positions. The resulting images are then processed to reconstruct the observed object with SR and/or OS. In this work, we present BOSSA-SIM, a general-purpose SIM reconstruction method, applicable to moving objects such as encountered in in vivo retinal imaging, that enables SR and OS jointly in a fully unsupervised Bayesian framework. By modeling a 2-layer object composed of an in-focus layer and a defocused layer, we show that BOSSA-SIM is able to jointly reconstruct them so as to get a super-resolved and optically sectioned in-focus layer. The achieved performance, assessed quantitatively by simulations for several noise levels, compares favorably with a state-of-the-art method. Finally, we validate our method on open-access experimental microscopy data.

preprint2016arXiv

High speed optical holography of retinal blood flow

We performed non-invasive video imaging of retinal blood flow in a pigmented rat by holographic interferometry of near-infrared laser light backscattered by retinal tissue, beating against an off-axis reference beam sampled at a frame rate of 39 kHz with a high throughput camera. Local Doppler contrasts emerged from the envelopes of short-time Fourier transforms and the phase of autocorrelation functions of holograms rendered by Fresnel transformation. This approach permitted imaging of blood flow in large retinal vessels (30 microns diameter) over 400 by 400 pixels with a spatial resolution of 8 microns and a temporal resolution of 6.5 ms.

preprint2010arXiv

Holographic laser Doppler ophthalmoscopy

We report laser Doppler ophthalmoscopic fundus imaging in the rat eye with near-IR heterodyne holography. Sequential sampling of the beat of the reflected radiation against a frequency-shifted optical local oscillator is made onto an array detector. Wide-field maps of fluctuation spectra in the 10 Hz to 25 kHz band exhibit angiographic contrasts in the retinal vascular tree without requirement of an exogenous marker.