Researcher profile

Michael Atlan

Michael Atlan contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
10works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2020arXiv

Real-time digital holography of the retina by principal component analysis

We demonstrate the feasibility of high-quality digital holography of the human retina in real-time with a fast camera and commodity computer hardware. High throughput rendering of digital Fresnel holograms from optically-acquired inline interferograms is performed in conjunction with temporal demodulation by projection of hologram sequences onto a data-derived basis in order to discriminate local narrowband coherent detection contrasts, mostly due to blood flow and optical absorption, from spurious interferometric contributions. Digital holograms are calculated from a sustained input stream of 16-bit, 1024-by-1024-pixel interferograms recorded at up to 500 frames per second, processed by principal component analysis. This temporal signal demodulation scheme consists in the projection of stacks of 32 consecutive holograms onto a basis calculated by eigendecomposition of the matrix of their time-lagged covariance; it is performed up to 20 times per second with commodity computer hardware.

preprint2020arXiv

Reverse contrast laser Doppler holography for lower frame rate retinal and choroidal blood flow imaging

Laser Doppler holography (LDH) is an interferometric blood flow imaging technique based on full-field measurements of the Doppler spectrum. LDH has so far been demonstrated in the retina with ultrafast cameras, typically at 75 kHz. We show here that a similar method can be implemented with camera frame rates 10 times slower than before. Thanks to energy conservation, low and high frequency local power Doppler signals have opposite variations, and a simple contrast inversion of the low frequency power Doppler reveals fast blood flow beyond the camera detection bandwidth for conventional laser Doppler measurements. Relevant blood flow variations and color composite power Doppler images can be obtained with camera frame rates down to a few kHz.

preprint2020arXiv

Spatio-temporal filtering in laser Doppler holography for retinal blood flow imaging

Laser Doppler holography (LDH) is a full-field interferometric imaging technique recently applied in ophthalmology to measure blood flow, a parameter of high clinical interest. From the temporal fluctuations of digital holograms acquired at ultrafast frame rates, LDH reveals retinal and choroidal blood flow with a few milliseconds of temporal resolution. However LDH experiences difficulties to detect slower blood flow as it requires to work with low Doppler frequency shifts which are corrupted by eye motion. We here demonstrate the use of a spatio-temporal decomposition adapted from Doppler ultrasound that provides a basis appropriate to the discrimination of blood flow from eye motion. A singular value decomposition (SVD) can be used as a simple, robust, and efficient way to separate the Doppler fluctuations of blood flow from those of strong spatial coherence such as eye motion. We show that the SVD outperforms the conventional Fourier based filter to reveal slower blood flow, and dramatically improves the ability of LDH to reveal vessels of smaller size or with a pathologically reduced blood flow.

preprint2012arXiv

Digital Holography at Shot Noise Level

By a proper arrangement of a digital holography setup, that combines off-axis geometry with phase-shifting recording conditions, it is possible to reach the theoretical shot noise limit, in real-time experiments.We studied this limit, and we show that it corresponds to 1 photo-electron per pixel within the whole frame sequence that is used to reconstruct the holographic image. We also show that Monte Carlo noise synthesis onto holograms measured at high illumination levels enables accurate representation of the experimental holograms measured at very weak illumination levels. An experimental validation of these results is done.

preprint2012arXiv

Exploring shot noise and Laser Doppler imagery with heterodyne holography

Heterodyne Holography is a variant of Digital Holography, where the optical frequencies of signal and reference arms can be freely adjusted by acousto-optic modulators. Heterodyne Holography is an extremely versatile and reliable holographic technique, which is able the reach the shot noise limit in sensitivity at very low levels of signal. Frequency tuning enables Heterodyne Holography to become a Laser Doppler imaging technique that is able to analyze various kinds of motion.

preprint2011arXiv

3D exploration of light scattering from live cells in the presence of gold nanomarkers using holographic microscopy

In this paper, we explore the 3D structure of light scattering from dark-field illuminated live 3T3 cells in the presence of 40 nm gold nanomarkers. For this purpose, we use a high resolution holographic microscope combining the off-axis heterodyne geometry and the phase-shifting acquisition of the digital holograms. A comparative study of the 3D reconstructions of the scattered fields allows us to locate the gold markers which yield, contrarily to the cell structures, well defined bright scattering patterns that are not angularly titled and clearly located along the optical axis (z). This characterization is an unambiguous signature of the presence of gold biological nanomarkers, and validates the capability of digital holographic microscopy to discriminate them from background signals in live ce

preprint2011arXiv

Off-axis digital hologram reconstruction: some practical considerations

Holographic rendering of off-axis intensity digital holograms is discussed. A review of some of the main numerical processing methods, based either on the Fourier transform interpretation of the propagation integral or on its linear system counterpart, is reported. Less common methods such as adjustable magnification reconstruction schemes and Fresnelet decomposition are presented and applied to the digital treatment of off-axis holograms. The influence of experimental parameters on the classical hologram reconstruction methods is assessed, offering guidelines for optimal image rendering regarding the hologram recording conditions.

preprint2010arXiv

Holographic laser Doppler ophthalmoscopy

We report laser Doppler ophthalmoscopic fundus imaging in the rat eye with near-IR heterodyne holography. Sequential sampling of the beat of the reflected radiation against a frequency-shifted optical local oscillator is made onto an array detector. Wide-field maps of fluctuation spectra in the 10 Hz to 25 kHz band exhibit angiographic contrasts in the retinal vascular tree without requirement of an exogenous marker.

preprint2010arXiv

Parallel heterodyne detection of dynamic light scattering spectra from gold nanoparticles diffusing in viscous fluids

We developed a microscope intended to probe, using a parallel heterodyne receiver, the fluctuation spectrum of light quasi-elastically scattered by gold nanoparticles diffusing in viscous fluids. The cutoff frequencies of the recorded spectra scale up linearly with those expected from single scattering formalism in a wide range of dynamic viscosities (1 to 15 times water viscosity at room temperature). Our scheme enables ensemble-averaged optical fluctuations measurements over multispeckle recordings in low light, at temporal frequencies up to 10 kHz, with a 12 Hz framerate array detector.