Source author record

Michael E. Tobar

Michael E. Tobar appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

59works
17topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

59 published item(s)

preprint2022arXiv

Can Traditional Terrestrial Applications of Gravity Gradiometry Rely Upon Quantum Technologies ? A Side View

The era of practical terrestrial applications of gravity gradiometry begun in 1890 when Baron Lorand von Eötvös, a Hungarian nobleman and a talented physicist and engineer, invented his famous torsion balance - the first practical gravity gradients measuring device. It was credited for the major oil discoveries later in Texas (USA). A 100 years later Kasevich and Chu pioneered the use of quantum physics for gravity gradient measurements. Since then cold-atom gravity gradiometers, or matter-wave gravity gradiometers, had been under development at almost every physics department of top-rated universities around the globe. After another 30 years since the Kasevich and Chu publication in 1992, which had led to the first ever quantum gravity gradiometer, the corresponding research and development ceased from being profoundly active a few years back. This article is an attempt to understand and explain what may have happened to the Quantum Invasion into the area of applied physics and precision engineering that traditionally has been occupied by non-quantum technologies developed for about a 130 years of the history of gravity gradiometry.

preprint2022arXiv

Direct Search for Dark Matter Axions Excluding ALP Cogenesis in the 63-67 micro-eV Range, with The ORGAN Experiment

The standard model axion seesaw Higgs portal inflation (SMASH) model is a well motivated, self-contained description of particle physics over a range of energy scales that predicts axion dark matter particles to exist within the mass range of $50-200\,μ$eV. To scan these masses an axion haloscope under a strong constant magnetic field must operate between 12 to 48 GHz. The ORGAN experiment (situated in Perth, Australia) is a microwave cavity axion haloscope that aims to search the majority of the mass range predicted by the SMASH model. Here we present results of Phase 1a, the first experiment to scan and search for axions in the microwave Ku Band. Our initial scan sets a new limit on the coupling of axions to two photons of $g_{aγγ}\geq 3\times 10^{-12}\, \textrm{GeV}^{-1}$ over the mass range $63.2$ to $67.1~μ$eV with $95\%$ confidence. This result is the most sensitive to date in this mass range, sufficient to exclude the well motivated ALP (Axion Like Particle) cogenesis model for dark matter, which adds ALPs to the standard model in the early universe to simultaneously explain the observed baryon and dark matter densities. To attain this level of sensitivity we utilised a TM$_{010}$ cylindrical cavity resonator, scanned between 15.28 to 16.23 GHz through the utilisation of a tuning rod. Measurements were performed over a duration of 3.5 weeks with a $74\%$ duty cycle, with the resonator coupled to a low noise HEMT amplifier and placed inside a superconducting solenoidal electromagnet of 11.5 Tesla in magnetic field strength.

preprint2021arXiv

The Electrodynamics of Free and Bound Charge Electricity Generators using Impressed Sources and the Modification to Maxwell's Equations

The conversion of external energy into electricity is the foundation of power station and energy harvesting operation. The external source supplies an impressed force per unit charge to free or bound charge to produces AC electricity. We analyze the electrodynamics of ideal electricity generators through a time dependent permanent polarization without any applied electric field, which modifies the constitutive relations and is essential to oscillate charge in a lossless way. For both cases, we show that Maxwell's equations, and in particular Faraday's law are modified, along with the required boundary conditions through the addition of an effective impressed magnetic current boundary source. For the free charge case, we highlight the example of an electromagnetic generator based on Lorentz force, where the impressed force per unit charge that polarizes the conductor comes from mechanical motion of free charge with an impressed velocity of a conductor relative to a stationary DC magnetic field. The bound charge generator is an idealized permanently polarized bar electret with a time dependent permanent polarization, the underlying principle behind piezoelectric nano-generators. In the open circuit state, both electricity generators are equivalent to idealized Hertzian dipoles, with the open circuit voltage equal to the induced emf. Analyzing the short circuit responses, we show that the bound charge electricity generator has a capacitive source impedance. In contrast, we show for the ideal free charge AC electricity generator, the back emf from the inductance of the loop that defines the short circuit, directly cancels the source emf, so the voltage across the inductor is solely determined by the magnetic current boundary source. Thus, we determine the magnetic current boundary source is the topological invariant that best describes the output voltage of an AC generator.

preprint2020arXiv

Generation of Spectrally Pure Microwave Signals

Based on the principles of microwave circuit interferometry we have constructed a Reduced Noise Amplifier (RNA) with power spectral density of phase, as well as amplitude, fluctuations close to -170 dBc/Hz at 1 kHz offset. The RNA has been incorporated with a cryogenic sapphire resonator as a loop oscillator whose noise performance is governed by the Leeson's model. Following this model and using the results of in-situ measurements of gain and phase fluctuations of the RNA we inferred noise properties of the oscillator. In particular, for a signal transmitted through the resonator we found that power spectral density of its phase/amplitude fluctuations must be close to -185 dBc/Hz at offsets above 300 Hz. We discuss a few approaches that will allow direct measurements of such low levels of noise.

preprint2020arXiv

Generation of Ultra-Low Power Phononic Combs

We demonstrate excitation of phononic frequency combs in a Bulk Acoustic Wave system at a temperature of $20$mK using a single tone low power signal source. The observed ultra low power threshold is due to a combination of very high quality factor of $4.2\times 10^8$ and relatively strong nonlinear effects. The observed repetition rate of the comb varies from 0.7 to 2Hz and spans over tens of Hertz. The demonstrated system is fully excited via piezoelectricity and does not require mode spectra engineering and external optical or microwave signals. It is shown that the comb profile significantly depends on geometry of excitation and detection electrodes. Observed strong Duffing nonlinearity below the generation threshold suggests that the system is a phononic analogue to Kerr frequency combs excited in monolithic optical microresonators. The ultra-low power regime opens a way of integrating this phononic system with quantum hybrid systems such as impurity defects and superconducting qubits.

preprint2020arXiv

Observation of Low Temperature Magneto-Mechanic Effects in Crystalline Resonant Phonon Cavities

We observe magnetic effects in ultra-high quality factor crystalline quartz Bulk Acoustic Wave resonators at milli-Kelvin temperature. The study reveals existence of hysteresis loops, jumps and memory effects of acoustical resonance frequencies. These loops arise as a response to the external magnetic field and span over few Hertz range for modes with linewidths of about $25$mHz, which constitute a frequency shift of order 60 linewidths. The effects are broadband but get stronger towards higher frequencies where both nonlinear effects and losses are limited by two level systems. This suggests that the observed effects are due to ferromagnet-like phase of a spin ensemble coupled to mechanical modes. The observed coupling between mechanical and spin degrees of freedom in the ultra low loss regime brings new possibilities for the emerging class of quantum hybrid systems.

preprint2017arXiv

The ORGAN Experiment: An axion haloscope above 15 GHz

We present first results and future plans for the Oscillating Resonant Group AxioN (ORGAN) experiment, a microwave cavity axion haloscope situated in Perth, Western Australia designed to probe for high mass axions motivated by several theoretical models. The first stage focuses around 26.6 GHz in order to directly test a claimed result, which suggests axions exist at the corresponding mass of $110~μ$eV. Later stages will move to a wider scan range of 15-50 GHz ($60-210~μ$eV). We present the results of the pathfinding run, which sets a limit on $g_{aγγ}$ of $2.02\times 10^{-12} $eV$^{-1}$ at 26.531 GHz, or 110~$μ$eV, in a span of 2.5 neV (shaped by the Lorentzian resonance) with $90 \%$ confidence. Furthermore, we outline the current design and future strategies to eventually attain the sensitivity to search for well known axion models over the wider mass range.

preprint2016arXiv

3D Lumped LC Resonators as Low Mass Axion Haloscopes

The axion is a hypothetical particle considered to be the most economical solution to the strong CP problem. It can also be formulated as a compelling component of dark matter. The haloscope, a leading axion detection scheme, relies on the conversion of galactic halo axions into real photons inside a resonant cavity structure in the presence of a static magnetic field, where the generated photon frequency corresponds to the mass of the axion. For maximum sensitivity it is key that the central frequency of the cavity mode structure coincides with the frequency of the generated photon. As the mass of the axion is unknown, it is necessary to perform searches over a wide range of frequencies. Currently there are substantial regions of the promising pre-inflationary low mass axion range without any viable proposals for experimental searches. We show that 3D resonant LC circuits with separated magnetic and electric fields, commonly known as re-entrant cavities, can be sensitive dark matter haloscopes in this region, with frequencies inherently lower than those achievable in the equivalent size of empty resonant cavity. We calculate the sensitivity and accessible axion mass range of these experiments, designing geometries to exploit and maximize the separated magnetic and electric coupling of the axion to the cavity mode.

preprint2016arXiv

A 3D Printed Superconducting Aluminium Microwave Cavity

3D printing of plastics, ceramics, and metals has existed for several decades and has revolutionized many areas of manufacturing and science. Printing of metals in particular has found a number of applications in fields as diverse as customized medical implants, jet engine bearings, and rapid prototyping in the automotive industry. Whilst many techniques can be used for 3D printing metals, they commonly rely on computer controlled melting or sintering of a metal alloy powder using a laser or electron beam. The mechanical properties of parts produced in such a way have been well studied, but little attention has been paid to their electrical properties. Here we show that a microwave cavity (resonant frequencies 9.9 and 11.2 GHz) 3D printed using an Al-12Si alloy exhibits superconductivity when cooled below the critical temperature of aluminium (1.2 K), with a performance comparable to the common 6061 alloy of aluminium. Superconducting cavities find application in numerous areas of physics, from particle accelerators to cavity quantum electrodynamics experiments. The result is achieved even with a very large concentration of non-superconducting silicon in the alloy of 12.18%, compared to Al-6061, which has between 0.4 to 0.8%. Our results may pave the way for the possibility of 3D printing superconducting cavity configurations that are otherwise impossible to machine.

preprint2016arXiv

A new method of probing mechanical losses of coatings at cryogenic temperatures

A new method of probing mechanical losses and comparing the corresponding deposition processes of metallic and dielectric coatings in 1-100 MHz frequency range and cryogenic temperatures is presented. The method is based on the use of extremely high-quality quartz acoustic cavities whose internal losses are orders of magnitude lower than any available coatings nowadays. The approach is demonstrated for Chromium, Chromium/Gold and a multilayer tantala/silica coatings. The ${\rm Ta}_2{\rm O}_5/{\rm Si}{\rm O}_2$ coating has been found to exhibit a loss angle lower than $1.6\times10^{-5}$ near 30 {\rm MHz} at 4 {\rm K}. The results are compared to the previous measurements.

preprint2016arXiv

High and low mass Axion Haloscopes at UWA

We consider the design of a haloscope experiment (ORGAN) to probe for axions at 26.6 GHz. The motivation for this search is to perform the first direct test of a result which claims a possible axion signal at this frequency. There are many technical issues and optimisations that must be considered in the design of a high mass axion haloscope. We discuss the current status of the ORGAN experiment, as well as its future. We also discuss low mass axion haloscopes employing lumped 3D LC resonators.

preprint2016arXiv

Reconfigurable Microwave Photonic Topological Insulator

Using full 3D finite element simulation and underlining Hamiltonian models, we demonstrate reconfigurable photonic analogues of topological insulators on a regular lattice of tunable posts in a re-entrant 3D lumped element type system. The tunability allows dynamical {\it in-situ} change of media chirality and other properties via alteration of the same parameter for all posts, and as a result, great flexibility in choice of bulk/edge configurations. Additionally, one way photon transport without an external magnetic field is demonstrated. The ideas are illustrated by using both full finite element simulation as well as simplified harmonic oscillator models. Dynamical reconfigurability of the proposed systems paves the way to a new class of systems that can be employed for random access, topological signal processing and sensing.

preprint2016arXiv

Superstrong Coupling of a Microwave Cavity to YIG Magnons

Multiple-post reentrant 3D lumped cavity modes have been realized to design the concept of discrete Whispering Gallery and Fabry-Perot-like Modes for multimode microwave Quantum Electrodynamics experiments. Using a magnon spin-wave resonance of a submillimeter-sized Yttrium-Iron-Garnet sphere at milliKelvin temperatures and a four-post cavity, we demonstrate the ultra-strong coupling regime between discrete Whispering Gallery Modes and a magnon resonance with strength of 1.84 GHz. By increasing the number of posts to eight and arranging them in a D$_4$ symmetry pattern, we expand the mode structure to that of a discrete Fabry-Perot cavity and modify the Free Spectral Range (FSR). We reach the superstrong coupling regime, where spin-photon coupling strength is larger than FSR, with coupling strength in the 1.1 to 1.5 GHz range.

preprint2015arXiv

Bounds on higher-order Lorentz-violating photon sector coefficients from an asymmetric optical ring resonator experiment

Optical resonators provide a powerful tool for testing aspects of Lorentz invariance. Here, we present a reanalysis of an experiment where a path asymmetry was created in an optical ring resonator by introducing a dielectric prism in one arm. The frequency difference of the two fundamental counter-propagating modes was then recorded as the apparatus was orientation-modulated in the laboratory. By assuming that the minimal Standard-Model Extension coefficients vanish we are able to place bounds on higher-order parity-odd Lorentz-violating coefficients of the Standard-Model Extension. The results presented in this work set the first constraints on two previously unbounded linear combinations of d=8 parity-odd nonbirefringent nondispersive coefficients of the photon sector.

preprint2015arXiv

Collective Behaviour of Cr$^{3+}$ ions in Ruby Revealed by Whispering Gallery Modes

We present evidence for collective action of Cr$^{3+}$ ion impurities in a highly doped ruby crystal at microwave frequencies. The cylindrical geometry of the crystal allows for the creation of a superradiant, or "spin-mode" doublet, with spatial structure similar to that of microwave whispering gallery modes (WGMs). This results in a strict criteria of selection rules regarding the interaction of resonant WGMs and spin-modes; namely that only modes with the same wavenumber and azimuthal phase may interact. What results is an avoided level crossing between the two, in which both WGM doublet constituents are seen to interact with the spin resonance. We demonstrate that a four harmonic oscillator model is necessary to accurately describe this result.

preprint2015arXiv

Creating Tuneable Microwave Media from a Two-Dimensional Lattice of Re-entrant Posts

The potential capabilities of resonators based on two dimensional arrays of re-entrant posts is demonstrated. Such posts may be regarded as magnetically-coupled lumped element microwave harmonic oscillators, arranged in a 2D lattices structure, which is enclosed in a 3D cavity. By arranging these elements in certain 2D patterns, we demonstrate how to achieve certain requirements with respect to field localisation and device spectra. Special attention is paid to symmetries of the lattices, mechanical tuning, design of areas of high localisation of magnetic energy, which in turn creates unique discrete mode spectra. We demonstrate analogies between systems designed on the proposed platform and well known physical phenomena such as polarisation, frustration and Whispering Gallery Modes. The mechanical tunability of the cavity with multiple posts is analysed and its consequences to optomechanical applications is calculated. One particular application to quantum memory is demonstrated with a cavity design consisting of separate resonators analogous to discrete Fabry-Pérot resonators. Finally, we propose a generalised approach to a microwave system design based on the concept of Programmable Cavity Arrays.

preprint2015arXiv

Determination of the Anisotropy of Permittivity of Quantum Paraelectric Strontium Titanate

The dielectric properties of strontium titanate (SrTiO$_3$) have previously been reported from room temperature to low temperatures with conflicting results. In this work, precision measurement of the permittivity is undertaken by simultaneously measuring transverse electric and transverse magnetic resonant modes within a single crystal. It is unequivocally shown that the permittivity is isotropic at room temperature with a permittivity of order $316.3\pm2.2$ by measuring multiple modes of different electric field polarisations. As the crystal is cooled to 5 K and undergoes well known phase transitions, we show the material becomes uniaxial anisotropic with the ratio of the parallel to perpendicular permittivity to the cylinder z-axis of the sample as high as 2.4 below 6 K.

preprint2015arXiv

Single Photon Level Study of Microwave Properties of Lithium Niobate at milli-Kelvin Temperatures

Properties of doped and natural impurities in Lithium Niobate single crystals are studied using the Whispering Gallery Mode method at low temperatures as a function of magnetic field. The study reveals considerable coupling of microwave photon modes to the Fe$^{3+}$ spin ensemble in iron-doped and non-doped crystals. The $S=5/2$ structure of the Fe$^{3+}$ impurities demonstrate Zero Field Splittings of $11.21$ and $20.96$ GHz, significant asymmetry of the Zeeman lines and additional lines with anomalous $\text{g}$-factors of $1.37$ and $3.95$. Also, interactions between different transitions of the Fe$^{3+}$ ion is observed. An additional ion impurity ensemble with a splitting of about $1.7$ GHz is shown to couple to the dominating Fe$^{3+}$ spins and the effect on $Q$-factors of microwave photon modes due to the Fe$^{3+}$ ion ensemble is also demonstrated. Measurements down to less than one photon level are made with a loss tangent of order $10^{-5}$ determined.

preprint2015arXiv

Strong Coupling Between Whispering Gallery Photons and Spin States of Iron Group Impurity Ions

Interaction of Whispering Gallery Modes (WGM) with dilute spin ensembles in solids is an interesting paradigm of Hybrid Quantum Systems potentially beneficial for Quantum Signal Processing applications. In the present work, WGM spectroscopy of Rare-Earth doped YSO crystal reveals the existence of Iron Group Ion (IGI) co-dopings with concentration levels of order 100 ppb. The IGI spin ensembles demonstrate large Zero Field Splittings at 14.7GHz, 18.4GHz and 25.4GHz, considerable anisotropy of the \textrm{g}-tensors, as well as two inequivalent lattice sites. Strong coupling regimes between an ensemble of IGI spins and WGM photons have been demonstrated at $18.4$ GHz and near zero field. This approach together with useful optical properties of these ions opens a new avenue for 'spins-in-solids' Quantum Electrodynamics.

preprint2014arXiv

Cryogenic resonant microwave cavity searches for hidden sector photons

The hidden sector photon is a weakly interacting hypothetical particle with sub-eV mass that kinetically mixes with the photon. We describe a microwave frequency light shining through a wall experiment where a cryogenic resonant microwave cavity is used to try and detect photons that have passed through an impenetrable barrier, a process only possible via mixing with hidden sector photons. For a hidden sector photon mass of 53 $μ$eV we limit the hidden photon kinetic mixing parameter $χ< 1.7\times10^{-7}$, which is an order of magnitude lower than previous bounds derived from cavity experiments in the same mass range. In addition, we use the cryogenic detector cavity to place new limits on the kinetic mixing parameter for hidden sector photons as a form of cold dark matter.

preprint2014arXiv

Effects of Geometry on Near Quantum Ground State Behaviour of Phonon-Trapping Acoustic Cavities

This work presents some peculiarities of the near quantum ground state behaviour of curved (phonon trapping) Bulk Acoustic Wave (BAW) cavities when compared to a conventional mechanical resonator. The curved cavity system resolves the quandary of the conventional mechanical system where the Bose-Einstein distribution requires higher frequencies for lower quantum occupation factors contrary to the constraint of an inverse frequency dependence of the quantum fluctuations of displacement. We demonstrate how the non-trivial cavity geometry can lead to better phonon trapping, enhancing the variance of zero-point-fluctuations of displacement. This variance becomes independent of overtone number (or BAW resonance frequency) overcoming the constraint and allowing better observation of quantum effects in a mechanical system. The piezoelectric electro-mechanical coupling approach is qualitatively compared to the parametric optomechanical technique for the curved BAW cavities. In both cases the detectible quantity grows proportional to the square root of the overtone number, and thus the resonance frequency. Also, the phonon trapping improves with higher overtone numbers, which allows the electrode size to be reduced such that in the optimal case the parasitic capacitive impedance becomes independent of the overtone number, allowing effective coupling to very high frequency overtones.

preprint2014arXiv

High Cooperativity Cavity QED with Magnons at Microwave Frequencies

Using a sub-millimetre sized YIG (Yttrium Iron Garnet) sphere mounted in a magnetic field-focusing cavity, we demonstrate an ultra-high cooperativity of $10^5$ between magnon and photon modes at millikelvin temperatures and microwave frequencies. The cavity is designed to act as a magnetic dipole by using a novel multiple-post approach, effectively focusing the cavity magnetic field within the YIG crystal with a filling factor of 3%. Coupling strength (normal-mode splitting) of 2 GHz, (equivalent to 76 cavity linewidths or $0.3$ Hz per spin), is achieved for a bright cavity mode that constitutes about 10% of the photon energy and shows that ultra-strong coupling is possible in spin systems at microwave frequencies. With straight forward optimisations we demonstrate that with that this system has the potential to reach cooperativities of $10^7$, corresponding to a normal mode splitting of 5.2 GHz and a coupling per spin approaching 1 Hz. We also observe a three-mode strong coupling regime between a dark cavity mode and a magnon mode doublet pair, where the photon-magnon and magnon-magnon couplings (normal-mode splittings) are 143 MHz and 12.5 MHz respectively, with HWHM bandwidth of about 0.5 MHz.

preprint2014arXiv

Hyperparametric effects in a whispering-gallery mode rutile dielectric resonator at liquid helium temperatures

We report the first observation of low power drive level sensitivity, hyperparametric amplification, and single-mode hyperparametric oscillations in a dielectric rutile whispering-gallery mode resonator at 4.2 K. The latter gives rise to a comb of sidebands at 19.756 GHz. Whereas, most frequency combs in the literature have been observed in optical systems using an ensemble of equally spaced modes in microresonators or fibers, the present work represents generation of a frequency comb using only a single-mode. The experimental observations are explained by an additional 1/2 degree-of-freedom originating from an intrinsic material nonlinearity at optical frequencies, which affects the microwave properties due to the extremely low loss of rutile. Using a model based on lumped circuits, we demonstrate that the resonance between the photonic and material 1/2 degree-of-freedom, is responsible for the hyperparametric energy transfer in the system.

preprint2014arXiv

Jump Chaotic Behaviour of Ultra Low Loss Bulk Acoustic Wave Cavities

We demonstrate a previously unobserved nonlinear phenomenon in an ultra-low loss quartz Bulk Acoustic Wave cavity ($Q>3\times10^9$), which only occurs below 20 milli-Kelvin in temperature and under relatively weak pumping. The phenomenon reveals the emergence of several stable equilibria (at least two foci and two nodes) and jumps between these quasi states at random times. The degree of this randomness as well as separations between levels can be controlled by the frequency of the incident carrier signal. It is demonstrated that the nature of the effect lays beyond the standard Duffing model.

preprint2014arXiv

Observation of the Fundamental Nyquist Noise Limit in an Ultra-High $Q$-Factor Cryogenic Bulk Acoustic Wave Cavity

Thermal Nyquist noise fluctuations of high-$Q$ Bulk Acoustic Wave (BAW) cavities have been observed at cryogenic temperatures with a DC Superconducting Quantum Interference Device (SQUID) amplifier. High $Q$ modes with bandwidths of few tens of milliHz produce thermal fluctuations with a Signal-To-Noise ratio of up to 23dB. The estimated effective temperature from the Nyquist noise is in good agreement with the physical temperature of the device, confirming the validity of the equivalent circuit model and the non-existence of any excess resonator self-noise. The measurements also confirm that the quality factor remains extremely high ($Q>10^8$ at low order overtones) for very weak (thermal) system motion at low temperatures, when compared to values measured with relatively strong external excitation. This result represents an enabling step towards operating such a high-Q acoustic device at the standard quantum limit.

preprint2014arXiv

Spectroscopy and laser cooling on the $^{1}S_{0}-\,^{3}P_{1}$ line in Yb via an injection-locked diode laser at 1111.6nm

We generate 555.8nm light with sub-MHz linewidth through the use of laser injection-locking of a semiconductor diode at 1111.6nm, followed by frequency doubling in a resonant cavity. The integrity of the injection lock is investigated by studying an offset-beat signal between slave and master lasers, by performing spectroscopy on the $(6s)^{2}$ $^{1}S_{0}-\,(6s6p)$ $^{3}P_{1}$ transition in magneto-optically trapped ytterbium, and by demonstrating additional laser cooling of $^{171}$Yb with the 555.8nm light. For the $^{1}S_{0}-$ $^{3}P_{1}$ spectroscopy, we confirm the linear dependence between ground state linewidth and the intensity of an off-resonant laser, namely, that used to cool Yb atoms in a $^{1}S_{0}-$ $^{1}P_{1}$ magneto-optical trap. Our results demonstrate the suitability of injection locked 1100-1130nm laser diodes as a source for sub-MHz linewidth radiation in the yellow-green spectrum.

preprint2014arXiv

Spin-Photon Interaction in a Cavity with Time-Reversal Symmetry Breaking

Employing a sapphire whispering gallery mode resonator, we demonstrate features of the spin-photon interaction in cavities with broken time-reflection symmetry. The broken symmetry leads to a lifting of the degeneracy between left-handed and right-handed polarised cavity photons, which results in an observable gyrotropic effect. In the high-$Q$ cavity limit, such a situation requires a modification of the Tavis-Cummings Hamiltonian to take into account conservation of spin angular momentum and the corresponding selection rules. As a result, the system is represented by a system of two linearly coupled bosonic modes, with each one coupled to its own sub-ensemble of two-level systems with different energy splittings. In the experimental example, these sub-ensembles originate from Fe$^{3+}$ impurity ions effectively seen as a two level systems at the interaction frequency. The temperature dependence of the population of each sub-ensemble (in terms of effective susceptibility of the medium) is determined experimentally in accordance with the theoretical predictions revealing various paramagnetic impurity types in the solid. The regimes of backscatterer and spin ensemble domination are discussed and compared.

preprint2014arXiv

Strong Coupling Between P1 Diamond Impurity Centres and 3D Lumped Photonic Microwave Cavity

We report strong coupling between an ensemble of N impurity (P1) centres in diamond and microwave photons using a unique double post re-entrant cavity. The cavity is designed so that the magnetic component of the cavity field is spatially separated from the electric component and focused into the small volume in which the diamond sample is mounted. The novelty of the structure simultaneously allows high magnetic filling factor (38.4\%) and low frequencies necessary to interact, at low magnetic field, with transitions in diamond such as those in NV$^{-}$ and P1 centres. Coupling strength (or normal-mode splitting) of 51.42 MHz, was achieved with P1 centres at 6.18 GHz and 220 mT in a centimetre-scale cavity, with a corresponding cooperativity factor of 4.7. This technique offers an alternative way, with some significant advantages, to couple 3D cavities to transitions in diamond and achieve the strong coupling necessary for applications to quantum information processing.

preprint2014arXiv

Strong Coupling between Whispering Gallery Modes and Chromium Ions in Ruby

We report the study of interactions between cavity photons and paramagnetic Cr$^{3+}$ spins in a ruby (Cr$^{3+}$:Al$_2$O$_3$) Whispering Gallery mode (WGM) resonator. Examining the system at microwave frequencies and millikelvin temperatures, spin-photon couplings up to 610 MHz or about 5% of photon energy are observed between the impurity spins and high quality factor ($Q > 10^5$) WGM. Large tunability and spin-spin interaction allows operation in the strong coupling regime. The system exhibits behaviour not predicted by the usual Tavis-Cummings model because of interactions within the two-level spin bath, and the existence of numerous photonic modes.

preprint2014arXiv

Sub-Doppler cooling of ytterbium with the $^{1}S_{0}$-$^{1}P_{1}$ transition including $^{171}$Yb (I=1/2)

We report on the sub-Doppler laser cooling of neutral $^{171}$Yb and $^{173}$Yb in a magneto-optical trap using the $^{1}S_{0}$-$^{1}P_{1}$ transition at 398.9nm. We use two independent means to estimate the temperature of the atomic cloud for several of the Yb isotopes. The two methods of MOT-cloud-imaging and release-and-recapture show consistency with one another. Temperatures below 400$μ$K and 200$μ$K are recorded for $^{171}$Yb and $^{173}$Yb, respectively, while ~1mK is measured for both $^{172}$Yb and $^{174}$Yb. By comparison, the associated 1D Doppler cooling temperature limit is 694$μ$K. The sub-Doppler cooling of the I=1/2 $^{171}$Yb isotope in a $σ^{+}-σ^{-}$ light-field trap adds further evidence that the Sisyphus cooling mechanism is occurring in such 3D magneto-optical traps.

preprint2014arXiv

The 3D Split-Ring Cavity Lattice: A New Metastructure for Engineering Arrays of Coupled Microwave Harmonic Oscillators

A new electromagnetic cavity structure, a lattice of 3D cavities consisting of an array of posts and gaps is presented. The individual cavity elements are based on the cylindrical re-entrant (or Klystron) cavity. We show that these cavities can also can be thought of as 3D split-ring resonators, which is confirmed by applying symmetry transformations, each of which is an electromagnetic resonator with spatially separated magnetic and electric field. The characteristics of the cavity is used to mimic phonon behaviour of a one dimensional chain of atoms. It is demonstrated how magnetic field coupling can lead to phonon-like dispersion curves with acoustical and optical branches. The system is able to reproduce a number of effects typical to one-dimensional lattices exhibiting acoustic vibration, such as band gaps, phonon trapping, and effects of impurities. In addition, quasicrystal emulations predict the results expected from this class of ordered structures. The system is easily scalable to simulate 2D and 3D lattices and shows a new way to engineer arrays of coupled microwave resonators with a variety of possible applications to hybrid quantum systems proposed.

preprint2013arXiv

Anomalously Strong Nonlinearity of Unswept Quartz Acoustic Cavities at Liquid Helium Temperatures

We demonstrate a variety of nonlinear phenomena at extremely low powers in cryogenic acoustic cavities fabricated from quartz material, which have not undergone any electrodiffusion processes. Nonlinear phenomena observed include lineshape discontinuities, power response discontinuities, quadrature oscillations and self-induced transparency. These phenomena are attributed to nonlinear dissipation through a large number of randomly distributed heavy trapped ions, which would normally be removed by electrodiffusion. A simple mean-field model predicts most of the observed phenomena. In contrast to Duffing-like systems, this system shows an unusual mechanism of nonlinearity, which is not related to crystal anharmonisity.

preprint2013arXiv

Controlling a whispering gallery doublet mode avoided frequency crossing: Strong coupling between photon bosonic and spin degrees of freedom

A combination of electron spin interactions in a magnetic field allows us to control the resonance frequencies of a high-Q Whispering Gallery (WG) cavity mode doublet, resulting in precise measurements of an avoided crossing between the two modes comprising the doublet. We show that the resonant photons effectively behave as spin--$\frac{1}{2}$ particles and that the physical origins of the doublet phenomenon arise from an energy splitting between the states of photon spin angular momentum. The exclusive role of the photon spin in splitting the mode frequency is emphasized, and we demonstrate that the gyrotropic and anisotropic properties of the crystalline media supporting the WG mode lead to strong coupling between the bosonic and spin degrees of freedom of cavity photons. Despite the demonstrated similarities with Jaynes-Cummings type systems, the mode doublet system exhibits a significant difference due to its linearity. Unlike traditional experiments dealing with interactions between fields and matter, here the crystalline medium plays a role of macroscopic symmetry breaking, assisting in the strong coupling between these photon degrees of freedom. Such a regime is demonstrated experimentally with a method to effectively control the photon spin state. Our experiments demonstrate for the first time, controllable time-reversal symmetry breaking in a high-$Q$ cavity.

preprint2013arXiv

Electromagnetic properties of polycrystalline diamond from 35K to room temperature and microwave to terahertz frequencies

Dielectric resonators are key components for many microwave and millimetre wave applications, including high-Q filters and frequency-determining elements for precision frequency synthesis. These often depend on the quality of the dielectric material. The commonly used material for building the best cryogenic microwave oscillators is sapphire. However sapphire is becoming a limiting factor for higher frequencies design. It is then important to find new candidates that can fulfil the requirements for millimetre wave low noise oscillators at room and cryogenic temperatures. These clocks are used as a reference in many fields, like modern telecommunication systems, radio astronomy (VLBI), and precision measurements at the quantum limit. High-resolution measurements were made of the temperature-dependence of the electromagnetic properties of a polycrystalline diamond disk at temperatures between 35 K and 330 K at microwave to sub-millimetre wave frequencies. The cryogenic measurements were made using a TE01δ dielectric mode resonator placed inside a vacuum chamber connected to a single-stage pulse-tube cryocooler. The high frequency characterization was performed at room temperature using a combination of a quasi-optical two-lens transmission setup, a Fabry-Perot cavity and a whispering gallery mode resonator excited with waveguides. Our CVD diamond sample exhibits a decreasing loss tangent with increasing frequencies. We compare the results with well known crystals. This comparison makes clear that polycrystalline diamond could be an important material to generate stable frequencies at millimetre waves.

preprint2013arXiv

Giant $g$-factors of Natural Impurities in Synthetic Quartz

We report the observation of $g$-factors of natural paramagnetic impurities in a pure synthetic quartz crystal at milli-Kelvin temperatures. Measurements are made by performing spectroscopy using multiple high-$Q$ Whispering Gallery Modes sustained in the crystal. Extreme sensitivity of the method at low temperatures allows the determination of natural residual impurities introduced during the crystal growth. We observe $g$-factors that significantly differ from integer multiples of the electron $g$-factor in vacuum, and with values of up to $7.6$, which reveals much stronger coupling between impurities and the crystal lattice than in previous studies. Both substitutional and interstitial ions are proposed as candidates for the observed interactions.

preprint2013arXiv

Hidden Sector Photon Coupling of Resonant Cavities

Many beyond the standard model theories introduce light paraphotons, a hypothetical spin-1 field that kinetically mixes with photons. Microwave cavity experiments have traditionally searched for paraphotons via transmission of power from an actively driven cavity to a passive receiver cavity, with the two cavities separated by a barrier that is impenetrable to photons. We extend this measurement technique to account for two-way coupling between the cavities and show that the presence of a paraphoton field can alter the resonant frequencies of the coupled cavity pair. We propose an experiment that exploits this effect and uses measurements of a cavities resonant frequency to constrain the paraphoton-photon mixing parameter, chi. We show that such an experiment can improve sensitivity to chi over existing experiments for paraphoton masses less than the resonant frequency of the cavity, and eliminate some of the most common systematics for resonant cavity experiments.

preprint2013arXiv

Hybrid Electron Spin Resonance and Whispering Gallery Mode Resonance Spectroscopy of Fe3+ in Sapphire

The development of a new era of quantum devices requires an understanding of how paramagnetic dopants or impurity spins behave in crystal hosts. Here, we describe a new spectroscopic technique which uses traditional Electron Spin Resonance (ESR) combined with the measurement of a large population of electromagnetic Whispering Gallery (WG) modes. This allows the characterization of the physical parameters of paramagnetic impurity ions in the crystal at low temperatures. We present measurements of two ultra-high purity sapphires cooled to 20 mK in temperature, and determine the concentration of Fe3+ ions and their frequency sensitivity to a DC magnetic field. Our method is different to ESR in that it is possible to track the resonant frequency of the ion from zero applied magnetic field to any arbitrary value, allowing excellent measurement precision. This high precision reveals anisotropic behaviour of the Zeeman splitting, which has not been previously reported. In both crystals, each Zeeman component demonstrates a different g-factor.

preprint2013arXiv

Resonator Power to Frequency Conversion in a Cryogenic Sapphire Oscillator

We report on the measurement and characterization of power to frequency conversion in the resonant mode of a cryogenic sapphire loaded cavity resonator, which is used as the frequency discriminating element of a loop oscillator circuit. Fluctuations of power incident on the resonator leads to changes in radiation pressure and temperature in the sapphire dielectric, both of which contribute to a shift in the resonance frequency. We measure a modulation and temperature independent radiation pressure induced power to frequency sensitivity of -0.15 Hz/mW and find that this is the primary factor limiting the stability of the resonator frequency.

preprint2013arXiv

Ultrasensitive microwave spectroscopy of paramagnetic impurities of sapphire crystals at millikelvin temperatures

Progress in the emerging field of engineered quantum systems requires the development of devices that can act as quantum memories. The realisation of such devices by doping solid state cavities with paramagnetic ions imposes a trade-off between ion concentration and cavity coherence time. Here, we investigate an alternative approach involving interactions between photons and naturally occurring impurity ions in ultra-pure crystalline microwave cavities exhibiting exceptionally high quality factors. We implement a hybrid Whispering Gallery/Electron Spin Resonance method to perform rigorous spectroscopy of an undoped single-crystal sapphire resonator over the frequency range 8--19 GHz, and at external applied DC magnetic fields up to 0.9 T. Measurements of a high purity sapphire cooled close to 100 mK reveal the presence of Fe$^{3+}$, Cr$^{3+}$, and V$^{2+}$ impurities. A host of electron transitions are measured and identified, including the two-photon classically forbidden quadrupole transition ($Δm_s =2$) for Fe$^{3+}$, as well as hyperfine transitions of V$^{2+}$.

preprint2012arXiv

Controlling the Frequency-Temperature Sensitivity of a Cryogenic Sapphire Maser Frequency Standard by Manipulating Fe3+ Spins in the Sapphire Lattice

To create a stable signal from a cryogenic sapphire maser frequency standard, the frequency-temperature dependence of the supporting Whispering Gallery mode must be annulled. We report the ability to control this dependence by manipulating the paramagnetic susceptibility of Fe3+ ions in the sapphire lattice. We show that the maser signal depends on other Whispering Gallery modes tuned to the pump signal near 31 GHz, and the annulment point can be controlled to exist between 5 to 10 K depending on the Fe3+ ion concentration and the frequency of the pump. This level of control has not been achieved previously, and will allow improvements in the stability of such devices.

preprint2012arXiv

Extremely Low-Loss Acoustic Phonons in a Quartz Bulk Acoustic Wave Resonator at Millikelvin Temperature

Low-loss, high frequency acoustic resonators cooled to millikelvin temperatures are a topic of great interest for application to hybrid quantum systems. When cooled to 20 mK, we show that resonant acoustic phonon modes in a Bulk Acoustic Wave (BAW) quartz resonator demonstrate exceptionally low loss (with $Q$-factors of order billions) at frequencies of 15.6 and 65.4 MHz, with a maximum $f.Q$ product of 7.8$\times10^{16}$ Hz. Given this result, we show that the $Q$-factor in such devices near the quantum ground state can be four orders of magnitude better than previously attained. Such resonators possess the low losses crucial for electromagnetic cooling to the phonon ground state, and the possibility of long coherence and interaction times of a few seconds, allowing multiple quantum gate operations.

preprint2012arXiv

Four Wave Mixing from Fe3+ Spins in Sapphire

Fe3+ ions in sapphire exhibit an Electron Spin Resonance (ESR) which interacts strongly with high-Q Whispering Gallery (WG) modes at microwave frequencies. We report the first observation of a third-order paramagnetic nonlinear susceptibility in such a resonator at cryogenic temperatures, and the first demonstration of four wave mixing (FWM) using this parametric nonlinearity. This observation of an all-microwave nonlinearity is an enabling step towards a host of quantum measurement and control applications which utilize spins in solids.

preprint2012arXiv

Frequency Conversion in a High Q-factor Sapphire Whispering Gallery Mode Resonator due to Paramagnetic Nonlinearity

Nonlinear frequency conversion is a well known and widely exploited family of effects in optics, often arising from a Kerr nonlinearity in a crystal medium. Here, we report high stability frequency conversion in the microwave regime due to a $χ^{(3)}$ nonlinearity in sapphire introduced by a dilute concentration of paramagnetic spins. First, we produce a high stability comb from two microwave fields at 12.029 and 12.037 GHz corresponding to two high $Q$-factor Whispering Gallery (WG) modes within the Electron Spin Resonance (ESR) bandwidth of the Fe$^{3+}$ ion. The resulting comb is generated by a cascaded four-wave mixing effect with a 7.7 MHz repetition rate. Then, by suppressing four-wave mixing by increasing the threshold power, third harmonic generation is achieved in a variety of WG modes coupled to various species of paramagnetic ion within the sapphire.

preprint2012arXiv

Improved tests of Local Position Invariance using 87Rb and 133Cs fountains

We report tests of local position invariance based on measurements of the ratio of the ground state hyperfine frequencies of 133Cs and 87Rb in laser-cooled atomic fountain clocks. Measurements extending over 14 years set a stringent limit to a possible variation with time of this ratio: d ln(nu_Rb/nu_Cs)/dt=(-1.39 +/- 0.91)x 10-16 yr-1. This improves by a factor of 7.7 over our previous report (H. Marion et al., Phys. Rev. Lett. 90, 150801 (2003)). Our measurements also set the first limit to a fractional variation of the Rb/Cs ratio with gravitational potential at the level of c^2 d ln(nu_Rb/nu_Cs)/dU=(0.11 +/- 1.04)x 10^-6, providing a new stringent differential redshift test. The above limits equivalently apply to the fractional variation of the quantity alpha^{-0.49}x(g_Rb/g_Cs), which involves the fine structure constant alpha and the ratio of the nuclear g-factors of the two alkalis. The link with variations of the light quark mass is also presented together with a global analysis combining with other available highly accurate clock comparisons.

preprint2012arXiv

Progress in Atomic Fountains at LNE-SYRTE

We give an overview of the work done with the Laboratoire National de Métrologie et d'Essais-Systèmes de Référence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed cavity phase shift, which we evaluate for the FO1 and FOM fountains, applying the techniques of our recent work on FO2. We also report calculations of the microwave lensing frequency shift for the three fountains, review the status of the blackbody radiation shift, and summarize recent experimental work to control microwave leakage and spurious phase perturbations. We give current accuracy budgets. We also describe several applications in time and frequency metrology: fountain comparisons, calibrations of the international atomic time, secondary representation of the SI second based on the 87Rb hyperfine frequency, absolute measurements of optical frequencies, tests of the T2L2 satellite laser link, and review fundamental physics applications of the LNE-SYRTE fountain ensemble. Finally, we give a summary of the tests of the PHARAO cold atom space clock performed using the FOM transportable fountain.

preprint2011arXiv

High Q-factor Sapphire Whispering Gallery Mode Microwave Resonator at Single Photon Energies and milli-Kelvin Temperatures

The microwave properties of a crystalline sapphire dielectric whispering gallery mode resonator have been measured at very low excitation strength (E/hf=1) and low temperatures (T = 30 mK). The measurements were sensitive enough to observe saturation due to a highly detuned electron spin resonance, which limited the loss tangent of the material to about 2e-8 measured at 13.868 and 13.259 GHz. Small power dependent frequency shifts were also measured which correspond to an added magnetic susceptibility of order 1e-9. This work shows that quantum limited microwave resonators with Q-factors > 1e8 are possible with the implementation of a sapphire whispering gallery mode system.

preprint2011arXiv

High Resolution Flicker-Noise-Free Frequency Measurements of Weak Microwave Signals

Amplification is usually necessary when measuring the frequency instability of microwave signals. In this work, we develop a flicker noise free frequency measurement system based on a common or shared amplifier. First, we show that correlated flicker phase noise can be cancelled in such a system. Then we compare the new system with the conventional by simultaneously measuring the beat frequency from two cryogenic sapphire oscillators with parts in 10^15 fractional frequency instability. We determine for low power, below -80 dBm, the measurements were not limited by correlated noise processes but by thermal noise of the readout amplifier. In this regime, we show that the new readout system performs as expected and at the same level as the standard system but with only half the number of amplifiers. We also show that, using a standard readout system, the next generation of cryogenic sapphire oscillators could be flicker phase noise limited when instability reaches parts in 10^16 or better

preprint2011arXiv

Microwave cavity hidden sector photon threshold crossing

Hidden sector photons are a weakly interacting slim particle arising from an additional U(1) gauge symmetry predicted by many standard model extensions. We present and demonstrate a new experimental method using a single microwave cavity to search for hidden sector photons. Only photons with a great enough energy are able to oscillate into hidden sector photons of a particular mass. If our cavity is driven on resonance and tuned over the corresponding threshold frequency, there is an observable drop in the circulating power signifying the creation of hidden sector photons. This approach avoids the problems of microwave leakage and frequency matching inherent in photon regeneration techniques.

preprint2011arXiv

Resonant Regeneration in the Sub-Quantum Regime -- A demonstration of fractional quantum interference

Light shining through wall experiments (in the optical as well as in the microwave regime) are a powerful tool to search for light particles coupled very weakly to photons such as axions or extra hidden sector photons. Resonant regeneration, where a resonant cavity is employed to enhance the regeneration rate of photons, is one of the most promising techniques to improve the sensitivity of the next generation of experiments. However, doubts have been voiced if such methods work at very low regeneration rates where on average the cavity contains less than one photon. In this note we report on a demonstration experiment using a microwave cavity driven with extremely low power, to show that resonant amplification works also in this regime. In accordance with standard quantum mechanics this is a demonstration that interference also works at the level of less than one quantum. As an additional benefit this experiment shows that thermal photons inside the cavity cause no adverse effects.

preprint2010arXiv

Detrapping and retrapping of free carriers in nominally pure single crystal GaP, GaAs and 4H-SiC semiconductors under light illumination at cryogenic temperatures

We report on extremely sensitive measurements of changes in the microwave properties of high purity non-intentionally-doped single-crystal semiconductor samples of gallium phosphide, gallium arsenide and 4H-silicon carbide when illuminated with light of different wavelengths at cryogenic temperatures. Whispering gallery modes were excited in the semiconductors whilst they were cooled on the coldfinger of a single-stage cryocooler and their frequencies and Q-factors measured under light and dark conditions. With these materials, the whispering gallery mode technique is able to resolve changes of a few parts per million in the permittivity and the microwave losses as compared with those measured in darkness. A phenomenological model is proposed to explain the observed changes, which result not from direct valence to conduction band transitions but from detrapping and retrapping of carriers from impurity/defect sites with ionization energies that lay in the semiconductor band gap. Detrapping and retrapping relaxation times have been evaluated from comparison with measured data.

preprint2010arXiv

Microwave cavity light shining through a wall optimization and experiment

It has been proposed that microwave cavities can be used in a photon regeneration experiment to search for hidden sector photons. Using two isolated cavities, the presence of hidden sector photons could be inferred from a 'light shining through a wall' phenomenon. The sensitivity of the experiment has strong a dependence on the geometric construction and electromagnetic mode properties of the two cavities. In this paper we perform an in depth investigation to determine the optimal setup for such an experiment. We also describe the results of our first microwave cavity experiment to search for hidden sector photons. The experiment consisted of two cylindrical copper cavities stacked axially inside a single vacuum chamber. At a hidden sector photon mass of 37.78 micro eV we place an upper limit on the kinetic mixing parameter chi = 2.9 * 10^(-5). Whilst this result lies within already established limits our experiment validates the microwave cavity `light shining through a wall' concept. We also show that the experiment has great scope for improvement, potentially able to reduce the current upper limit on the mixing parameter chi by several orders of magnitude.

preprint2010arXiv

Single Crystal Sapphire at milli-Kelvin Temperatures: Observation of Electromagnetically Induced Thermal Bistability in High Q-factor Whispering Gallery Modes

Resonance modes in single crystal sapphire ($α$-Al$_2$O$_3$) exhibit extremely high electrical and mechanical Q-factors ($\approx 10^9$ at 4K), which are important characteristics for electromechanical experiments at the quantum limit. We report the first cooldown of a bulk sapphire sample below superfluid liquid helium temperature (1.6K) to as low as 25mK. The electromagnetic properties were characterised at microwave frequencies, and we report the first observation of electromagnetically induced thermal bistability in whispering gallery modes due to the material $T^3$ dependence on thermal conductivity and the ultra-low dielectric loss tangent. We identify "magic temperatures" between 80 to 2100 mK, the lowest ever measured, at which the onset of bistability is suppressed and the frequency-temperature dependence is annulled. These phenomena at low temperatures make sapphire suitable for quantum metrology and ultra-stable clock applications, including the possible realization of the first quantum limited sapphire clock.

preprint2009arXiv

Modified permittivity observed in bulk Gallium Arsenide and Gallium Phosphide samples at 50 K using the Whispering Gallery mode method

Whispering Gallery modes in bulk cylindrical Gallium Arsenide and Gallium Phosphide samples have been examined both in darkness and under white light at 50 K. In both samples we observed change in permittivity under light and dark conditions. This results from a change in the polarization state of the semiconductor, which is consistent with a free electron-hole creation/recombination process. The permittivity of the semiconductor is modified by free photocarriers in the surface layers of the sample which is the region sampled by Whispering Gallery modes.

preprint2009arXiv

Rotating Odd-Parity Lorentz Invariance Test in Electrodynamics

We report the first operation of a rotating odd-parity Lorentz Invariance test in electrodynamics using a microwave Mach-Zehnder interferometer with permeable material in one arm. The experiment sets a direct bound to $ κ_{tr}$ of $-0.3\pm 3\times10^{-7}$. Using new power recycled waveguide interferometer techniques (with the highest spectral resolution ever achieved of $2\times10^{-11} rad/\sqrt{Hz}$) we show an improvement of several orders of magnitude is attainable in the future.

preprint2005arXiv

Recent Experimental Tests of Special Relativity

We review our recent Michelson-Morley (MM) and Kennedy-Thorndike (KT) experiment, which tests Lorentz invariance in the photon sector, and report first results of our ongoing atomic clock test of Lorentz invariance in the matter sector. The MM-KT experiment compares a cryogenic microwave resonator to a hydrogen maser, and has set the most stringent limit on a number of parameters in alternative theories to special relativity. We also report first results of a test of Lorentz invariance in the SME (Standard Model Extension) matter sector, using Zeeman transitions in a laser cooled Cs atomic fountain clock. We describe the experiment together with the theoretical model and analysis. Recent experimental results are presented and we give a first estimate of components of the $\tilde{c}^p$ parameters of the SME matter sector. A full analysis of systematic effects is still in progress, and will be the subject of a future publication together with our final results. If confirmed, the present limits would correspond to first ever measurements of some $\tilde{c}^p$ components, and improvements by 11 and 14 orders of magnitude on others.

preprint2005arXiv

Rotating Resonator-Oscillator Experiments to Test Lorentz Invariance in Electrodynamics

In this work we outline the two most commonly used test theories (RMS and SME) for testing Local Lorentz Invariance (LLI) of the photon. Then we develop the general framework of applying these test theories to resonator experiments with an emphasis on rotating experiments in the laboratory. We compare the inherent sensitivity factors of common experiments and propose some new configurations. Finally we apply the test theories to the rotating cryogenic experiment at the University of Western Australia, which recently set new limits in both the RMS and SME frameworks [hep-ph/0506074].

preprint2004arXiv

New methods of testing Lorentz violation in electrodynamics

We investigate experiments that are sensitive to the scalar and parity-odd coefficients for Lorentz violation in the photon sector of the Standard Model Extension (SME). We show that of the classic tests of special relativity, Ives-Stilwell (IS) experiments are sensitive to the scalar coefficient, but at only parts in 10^5 for the state-of-the-art experiment. We then propose asymmetric Mach-Zehnder interferometers with different electromagnetic properties in the two arms, including recycling techniques based on travelling wave resonators to improve the sensitivity. With present technology we estimate that the scalar and parity odd coefficients may be measured at sensitivity better than parts in 10^11 and 10^15 respectively.