Researcher profile

Matthew S. Kirchner

Matthew S. Kirchner contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - Baseline
3works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

Ultrafast 1 MHz vacuum-ultraviolet source via highly cascaded harmonic generation in negative-curvature hollow-core fibers

Vacuum ultraviolet (VUV) light is critical for the study of molecules and materials, but the generation of femtosecond pulses in the VUV region at high repetition rates has proven difficult. Here, we demonstrate the efficient generation of VUV light at MHz repetition rates using highly cascaded four-wave mixing processes in a negative-curvature hollow-core fiber. Both even and odd order harmonics are generated up to the 15th harmonic (69 nm, 18.0 eV), with high energy resolution of ~40 meV. In contrast to direct high harmonic generation, this highly cascaded harmonic generation process requires lower peak intensity and therefore can operate at higher repetition rates, driven by a robust ~10 W fiber-laser system in a compact setup. Additionally, we present numerical simulations that explore the fundamental capabilities and spatiotemporal dynamics of highly cascaded harmonic generation. This VUV source can enhance the capabilities of spectroscopies of molecular and quantum materials, such as photoionization mass spectrometry and time , angle , and spin-resolved photoemission.

preprint2011arXiv

Frequency-stabilization to 6x10^-16 via spectral-hole burning

We demonstrate two-stage laser stabilization based on a combination of Fabry- Perot and spectral-hole burning techniques. The laser is first pre-stabilized by the Fabry-Perot cavity to a fractional-frequency stability of sigma_y(tau) < 10^-13. A pattern of spectral holes written in the absorption spectrum of Eu3+:Y2SiO5 serves to further stabilize the laser to sigma_y(tau) = 6x10^-16 for 2 s < tau < 8 s. Measurements characterizing the frequency sensitivity of Eu3+:Y2SiO5 spectral holes to environmental perturbations suggest that they can be more frequency stable than Fabry-Perot cavities.

preprint2007arXiv

Human breath analysis via cavity-enhanced optical frequency comb spectroscopy

To date, researchers have identified over 1000 different compounds contained in human breath. These molecules have both endogenous and exogenous origins and provide information about physiological processes occurring in the body as well as environment-related ingestion or absorption of contaminants1,2. While the presence and concentration of many of these molecules are poorly understood, many 'biomarker' molecules have been correlated to specific diseases and metabolic processes. Such correlations can result in non-invasive methods of health screening for a wide variety of medical conditions. In this article we present human breath analysis using an optical-frequency-comb-based trace detection system with excellent performance in all criteria: detection sensitivity, ability to identify and distinguish a large number of biomarkers, and measurement time. We demonstrate a minimum detectable absorption of 8 x 10-10 cm-1, a spectral resolution of 800 MHz, and 200 nm of spectral coverage from 1.5 to 1.7 micron where strong and unique molecular fingerprints exist for many biomarkers. We present a series of breath measurements including stable isotope ratios of CO2, breath concentrations of CO, and the presence of trace concentrations of NH3 in high concentrations of H2O.