Source author record

Martin Uecker

Martin Uecker appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
11topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2026arXiv

Group-kernel auto-calibration and group-patch k-space reconstruction: Fast MRI with time-variant B0 kernels partitioned into time-invariant subsets

Purpose: Pushing MRI speed further demands more spatially-encoded information captured per unit time, e.g., by superimposing additional field modulations during oversampled readout. However, this can introduce calibration errors and increase reconstruction time. Thus, we propose a continuous field calibration approach and an efficient k-space reconstruction technique. Theory and Methods: Our auto-calibration generalizes GRAPPA kernels to explicitly extract continuous B0 modulation kernels, solving interpolation relationships between two ACS regions differing only in the extra field modulation. The k-space locations sharing the same instantaneous image-space modulation are grouped, so that subsets of time-invariant kernels can be separately estimated, as a generalized solution for Wave-CAIPI/FRONSAC-type scans. This view further inspires a k-space subregion-wise reconstruction technique, as an efficient alternative to conventional hybrid-space reconstruction. At 9.4T, FLASH accelerated by a local B0 coil array and Wave-CAIPI were tested with retrospective undersampling. Results: Artifact-free images were reconstructed, under diverse rapid B0 modulation schemes, reaching maximum acceleration factors of 8-fold in 2D and 14.6-fold in 3D. Some nonlinear gradients modulation schemes reach similar sampling efficiency as linear gradients modulation. The proposed reconstruction shows potentials in reducing reconstruction time. Conclusion: Rapid B0 modulations and widely-adopted parallel imaging can share a common mathematical framework, and consequently, achieve similarly-robust reconstructions. Specifically, for scans using dynamic B0 and static RF kernels, not only signal encoding, but also auto-calibration and reconstruction can be performed in k-space. This paves the way to robustly remove eddy currents, and explore more complex B0 modulation strategies towards ultimate MRI speed.

preprint2020arXiv

CG-SENSE revisited: Results from the first ISMRM reproducibility challenge

Purpose: The aim of this work is to shed light on the issue of reproducibility in MR image reconstruction in the context of a challenge. Participants had to recreate the results of "Advances in sensitivity encoding with arbitrary k-space trajectories" by Pruessmann et al. Methods: The task of the challenge was to reconstruct radially acquired multi-coil k-space data (brain/heart) following the method in the original paper, reproducing its key figures. Results were compared to consolidated reference implementations created after the challenge, accounting for the two most common programming languages used in the submissions (Matlab/Python). Results: Visually, differences between submissions were small. Pixel-wise differences originated from image orientation, assumed field-of-view or resolution. The reference implementations were in good agreement, both visually and in terms of image similarity metrics. Discussion and Conclusion: While the description level of the published algorithm enabled participants to reproduce CG-SENSE in general, details of the implementation varied, e.g., density compensation or Tikhonov regularization. Implicit assumptions about the data lead to further differences, emphasizing the importance of sufficient meta-data accompanying open data sets. Defining reproducibility quantitatively turned out to be non-trivial for this image reconstruction challenge, in the absence of ground-truth results. Typical similarity measures like NMSE of SSIM were misled by image intensity scaling and outlier pixels. Thus, to facilitate reproducibility, researchers are encouraged to publish code and data alongside the original paper. Future methodological papers on MR image reconstruction might benefit from the consolidated reference implementations of CG-SENSE presented here, as a benchmark for methods comparison.

preprint2020arXiv

Model-Based Reconstruction for Simultaneous Multi-Slice T1 Mapping using Single-Shot Inversion-Recovery Radial FLASH

Purpose: To develop a single-shot multi-slice T1 mapping method by combing simultaneous multi-slice (SMS) excitations, single-shot inversion-recovery (IR) radial fast low-angle shot (FLASH) and a nonlinear model-based reconstruction method. Methods: SMS excitations are combined with a single-shot IR radial FLASH sequence for data acquisition. A previously developed single-slice calibrationless model-based reconstruction is extended to SMS, formulating the estimation of parameter maps and coil sensitivities from all slices as a single nonlinear inverse problem. Joint-sparsity constraints are further applied to the parameter maps to improve T1 precision. Validations of the proposed method are performed for a phantom and for the human brain and liver in six healthy adult subjects. Results: Phantom results confirm good T1 accuracy and precision of the simultaneously acquired multi-slice T1 maps in comparison to single-slice references. In-vivo human brain studies demonstrate the better performance of SMS acquisitions compared to the conventional spoke-interleaved multi-slice acquisition using model-based reconstruction. Apart from good accuracy and precision, the results of six healthy subjects in both brain and abdominal studies confirm good repeatability between scan and re-scans. The proposed method can simultaneously acquire T1 maps for five slices of a human brain ($0.75 \times 0.75 \times 5$ mm$^3$) or three slices of the abdomen ($1.25 \times 1.25 \times 6$ mm$^3$) within four seconds. Conclusion: The IR SMS radial FLASH acquisition together with a non-linear model-based reconstruction enable rapid high-resolution multi-slice T1 mapping with good accuracy, precision, and repeatability.

preprint2019arXiv

Accelerating Non-Cartesian MRI Reconstruction Convergence using k-space Preconditioning

We propose a k-space preconditioning formulation for accelerating the convergence of iterative Magnetic Resonance Imaging (MRI) reconstructions from non-uniformly sampled k-space data. Existing methods either use sampling density compensations which sacrifice reconstruction accuracy, or circulant preconditioners which increase per-iteration computation. Our approach overcomes both shortcomings. Concretely, we show that viewing the reconstruction problem in the dual formulation allows us to precondition in k-space using density-compensation-like operations. Using the primal-dual hybrid gradient method, the proposed preconditioning method does not have inner loops and are competitive in accelerating convergence compared to existing algorithms. We derive l2-optimized preconditioners, and demonstrate through experiments that the proposed method converges in about ten iterations in practice.

preprint2018arXiv

Joint T1 and T2 Mapping with Tiny Dictionaries and Subspace-Constrained Reconstruction

Purpose: To develop a method that adaptively generates tiny dictionaries for joint T1-T2 mapping. Theory: This work breaks the bond between dictionary size and representation accuracy (i) by approximating the Bloch-response manifold by piece-wise linear functions and (ii) by adaptively refining the sampling grid depending on the locally-linear approximation error. Methods: Data acquisition was accomplished with use of an 2D radially sampled Inversion-Recovery Hybrid-State Free Precession sequence. Adaptive dictionaries are generated with different error tolerances and compared to a heuristically designed dictionary. Based on simulation results, tiny dictionaries were used for T1-T2 mapping in phantom and in vivo studies. Reconstruction and parameter mapping were performed entirely in subspace. Results: All experiments demonstrated excellent agreement between the proposed mapping technique and template matching using heuristic dictionaries. Conclusion: Adaptive dictionaries in combination with manifold projection allow to reduce the necessary dictionary sizes by one to two orders of magnitude.

preprint2016arXiv

Model-Based Iterative Reconstruction for Radial Fast Spin-Echo MRI

In radial fast spin-echo MRI, a set of overlapping spokes with an inconsistent T2 weighting is acquired, which results in an averaged image contrast when employing conventional image reconstruction techniques. This work demonstrates that the problem may be overcome with the use of a dedicated reconstruction method that further allows for T2 quantification by extracting the embedded relaxation information. Thus, the proposed reconstruction method directly yields a spin-density and relaxivity map from only a single radial data set. The method is based on an inverse formulation of the problem and involves a modeling of the received MRI signal. Because the solution is found by numerical optimization, the approach exploits all data acquired. Further, it handles multi-coil data and optionally allows for the incorporation of additional prior knowledge. Simulations and experimental results for a phantom and human brain in vivo demonstrate that the method yields spin-density and relaxivity maps that are neither affected by the typical artifacts from TE mixing, nor by streaking artifacts from the incomplete k-space coverage at individual echo times.

preprint2014arXiv

Fast T2 Mapping with Improved Accuracy Using Undersampled Spin-echo MRI and Model-based Reconstructions with a Generating Function

A model-based reconstruction technique for accelerated T2 mapping with improved accuracy is proposed using undersampled Cartesian spin-echo MRI data. The technique employs an advanced signal model for T2 relaxation that accounts for contributions from indirect echoes in a train of multiple spin echoes. An iterative solution of the nonlinear inverse reconstruction problem directly estimates spin-density and T2 maps from undersampled raw data. The algorithm is validated for simulated data as well as phantom and human brain MRI at 3 T. The performance of the advanced model is compared to conventional pixel-based fitting of echo-time images from fully sampled data. The proposed method yields more accurate T2 values than the mono-exponential model and allows for undersampling factors of at least 6. Although limitations are observed for very long T2 relaxation times, respective reconstruction problems may be overcome by a gradient dampening approach. The analytical gradient of the utilized cost function is included as Appendix.

preprint2014arXiv

Parallel Magnetic Resonance Imaging as Approximation in a Reproducing Kernel Hilbert Space

In Magnetic Resonance Imaging (MRI) data samples are collected in the spatial frequency domain (k-space), typically by time-consuming line-by-line scanning on a Cartesian grid. Scans can be accelerated by simultaneous acquisition of data using multiple receivers (parallel imaging), and by using more efficient non-Cartesian sampling schemes. As shown here, reconstruction from samples at arbitrary locations can be understood as approximation of vector-valued functions from the acquired samples and formulated using a Reproducing Kernel Hilbert Space (RKHS) with a matrix-valued kernel defined by the spatial sensitivities of the receive coils. This establishes a formal connection between approximation theory and parallel imaging. Theoretical tools from approximation theory can then be used to understand reconstruction in k-space and to extend the analysis of the effects of samples selection beyond the traditional g-factor noise analysis to both noise amplification and approximation errors. This is demonstrated with numerical examples.

preprint2013arXiv

A Multi-GPU Programming Library for Real-Time Applications

We present MGPU, a C++ programming library targeted at single-node multi-GPU systems. Such systems combine disproportionate floating point performance with high data locality and are thus well suited to implement real-time algorithms. We describe the library design, programming interface and implementation details in light of this specific problem domain. The core concepts of this work are a novel kind of container abstraction and MPI-like communication methods for intra-system communication. We further demonstrate how MGPU is used as a framework for porting existing GPU libraries to multi-device architectures. Putting our library to the test, we accelerate an iterative non-linear image reconstruction algorithm for real-time magnetic resonance imaging using multiple GPUs. We achieve a speed-up of about 1.7 using 2 GPUs and reach a final speed-up of 2.1 with 4 GPUs. These promising results lead us to conclude that multi-GPU systems are a viable solution for real-time MRI reconstruction as well as signal-processing applications in general.